Removal of the IDG Shut-off Sensor.
TASK 28-46-19-000-001-A
Removal of the IDG Shut-off Sensor.
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-46-19-941-051-A
Subtask 28-46-19-020-050-A
[Rev.10 from 2021]
2026.04.02 06:18:16 UTC
Removal of the IDG Shut-off Sensor.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [38QJ1] (SENSOR-LOW LEVEL, LEFT WING TK INNER CHANNEL A) | |
| 540AB | |
| FOR [38QJ2] (SENSOR-LOW LEVEL, RIGHT WING TK INNER CHANNEL A) | |
| 640AB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 28-25-00-650-003-A | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-650-003-A-01 | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 57-27-11-000-001-A | Removal of the Access Panel |
Subtask 28-46-19-941-051-A
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
Subtask 28-46-19-650-050-A WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
(1) You must obey the fuel safety procedures when you do work in a fuel tank (Ref. AMM TASK 28-10-00-910-001). (2) Put the SAFETY BARRIER(S) in position.
B. Fuel Configuration
(1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-46-19-865-053-A (1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 28-46-19-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/CTR TK/PUMPS1 AND 2/CTL AND IND | 32QA | R26 |
| 121VU | FUEL/CTR TK/PUMPS1 AND 2/CTL AND IND | 31QA | R25 |
| ** ON A/C ALL | |||
| 121VU | FUEL/PUMPS/2/R CTL AND L IND | 10QA | R29 |
| 121VU | FUEL/PUMPS/1/L CTL AND R IND | 3QA | R23 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/CTR TK/L&R XFR/CTL & IND | 2QL | R26 |
| 121VU | FUEL/CTR TK/L&R XFR/CTL & IND | 1QL | R25 |
D. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the applicable access panel 540AB (640AB).
(2) Remove the applicable access panel (Ref. AMM TASK 57-27-11-000-001) and (Ref. AMM TASK 28-10-00-910-002):
(a) FOR [38QJ1] (SENSOR-LOW LEVEL, LEFT WING TK INNER CHANNEL A)
remove 540AB
(b) FOR [38QJ2] (SENSOR-LOW LEVEL, RIGHT WING TK INNER CHANNEL A)
remove 640AB.
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the applicable access panel 540AB (640AB).
(2) Remove the applicable access panel (Ref. AMM TASK 57-27-11-000-001) and (Ref. AMM TASK 28-10-00-910-002):
(a) FOR [38QJ1] (SENSOR-LOW LEVEL, LEFT WING TK INNER CHANNEL A)
remove 540AB
(b) FOR [38QJ2] (SENSOR-LOW LEVEL, RIGHT WING TK INNER CHANNEL A)
remove 640AB.
Subtask 28-46-19-020-050-A
A. Removal of the IDG Shut-off Sensor
(1) Loosen the cable clamp screw (9) and release the cable (1).
(2) Loosen the electrical connector screws (5) and (6) and remove the cable (1).
(3) Put CAP - BLANKING on the disconnected electrical connections.
(4) Remove the bolts (3) and (7) and the washers (2) and (8) and remove the sensor (4).
(1) Loosen the cable clamp screw (9) and release the cable (1).
(2) Loosen the electrical connector screws (5) and (6) and remove the cable (1).
(3) Put CAP - BLANKING on the disconnected electrical connections.
(4) Remove the bolts (3) and (7) and the washers (2) and (8) and remove the sensor (4).
IDG Shut-off Sensor