W DOC AIRBUS | AMM A320F

Removal of the Temperature Sensor


TASK 28-46-17-000-002-A
Removal of the Temperature Sensor


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 30QJ1 ** ON A/C NOT FOR ALL
FIN: 30QJ2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [30QJ1] (SENSOR-TEMP, LEFT WING TK OUTER CHANNEL A)
540NB
FOR [30QJ2] (SENSOR-TEMP, RIGHT WING TK OUTER CHANNEL A)
640NB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 28-10-00-910-001-A
Safety Procedures When You Do Work in a Fuel Tank
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 28-25-00-650-001-A
Pressure Defuel
TASK 28-25-00-650-003-A
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 28-25-00-650-003-A-01
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 57-27-11-000-002-A
Removal of the Access Panel
3. Job Set-up
Subtask 28-46-17-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
WARNING: BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
   (1) You must obey the fuel safety procedures (Ref. AMM TASK 28-10-00-910-001) when you do work in a fuel tank.
   (2) Put the SAFETY BARRIER(S) in position.
Subtask 28-46-17-650-051-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
   (2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-46-17-865-051-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUFUEL/CTR TK/PUMPS1 AND 2/CTL AND IND32QAR26
121VUFUEL/CTR TK/PUMPS1 AND 2/CTL AND IND31QAR25
** ON A/C NOT FOR ALL
121VUFUEL/PUMPS/2/R CTL AND L IND10QAR29
121VUFUEL/PUMPS/1/L CTL AND R IND3QAR23
Subtask 28-46-17-010-051-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the applicable access panel 540NB (640NB).
   (2) Remove the applicable access panel 540NB (640NB) (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-002):
     (a) FOR [30QJ1] (SENSOR-TEMP, LEFT WING TK OUTER CHANNEL A)
remove 540NB
     (b) FOR [30QJ2] (SENSOR-TEMP, RIGHT WING TK OUTER CHANNEL A)
remove 640NB.
4. Procedure
Subtask 28-46-17-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Temperature Sensor 30QJ1 (30QJ2)
   (1) Loosen the cable clamp screw (9) and release the cable (1).
   (2) Loosen the electrical connector screws (4) and (5) and remove the cable (1).
   (3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (4) Remove the bolts (3) and (6) and the washers (2) and (7). Remove the sensor (8).
[Rev.10 from 2021] 2026.04.02 06:18:16 UTC