W DOC AIRBUS | AMM A320F

Removal of the Overflow Sensor


TASK 28-46-16-000-001-A
Removal of the Overflow Sensor


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
FIN: 28QJ1
FIN: 28QJ2
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 4M (13 FT)
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
550CB, 650CB
FOR [28QJ1] (SENSOR-HIGH LVL, LEFT WING SURGE TK CHANNEL A)
550CB
FOR [28QJ2] (SENSOR-HIGH LVL, RIGHT WING SURGE TK CHANNEL A)
650CB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 28-10-00-910-001-A
Safety Procedures When You Do Work in a Fuel Tank
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 28-12-45-000-001-A
Removal of the Panel Assembly
TASK 28-25-00-650-003-A
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 28-25-00-650-003-A-01
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
F Overflow Sensor ** ON A/C NOT FOR ALL
F Overflow Sensor ** ON A/C NOT FOR ALL
F Overflow Sensor ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 28-46-16-941-052-A
A. Safety Precautions
WARNING: BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
   (1) You must obey the fuel safety procedures (Ref. AMM TASK 28-10-00-910-001) when you do work in a fuel tank.
   (2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 28-46-16-650-050-A
B. Fuel Configuration
   (1) Drain the remaining fuel from the applicable surge tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-46-16-010-050-A
C. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable access panel 550CB 650CB.
   (2) Remove the applicable access panel (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 28-12-45-000-001):
     (a) FOR [28QJ1] (SENSOR-HIGH LVL, LEFT WING SURGE TK CHANNEL A)
remove 550CB
     (b) FOR [28QJ2] (SENSOR-HIGH LVL, RIGHT WING SURGE TK CHANNEL A)
remove 650CB.
Subtask 28-46-16-865-050-A
D. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFUEL/XFR VALVE1/WING/R2QPA11
49VUFUEL/XFR VALVE1/WING/L1QPA10
** ON A/C NOT FOR ALL
49VUFUEL/AFT LOW LVL/& OVFL/WING R44QJA11
49VUFUEL/AFT LOW LVL/& OVFL/WING L43QJA10
4. Procedure
Subtask 28-46-16-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Overflow Sensor
   (1) Loosen the cable clamp screw (4) and release the cable (5).
   (2) Loosen the electrical connector screws (8) and (9) and remove the cable (5).
   (3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (4) Remove the bolts (1) and (7) and the washers (2) and (6)
   (5) Remove the sensor (3) from the support bracket.
Subtask 28-46-16-020-050-B ** ON A/C NOT FOR ALL
A. Removal of the Overflow Sensor
   (1) Loosen the cable clamp screw (5) and release the cable (6).
   (2) Loosen the electrical connector screws (9) and (10) and remove the cable (6).
   (3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (4) Remove the bolts (1) and (8) and the washers (2) and (7).
   (5) Remove the sensor (3) and the cover (4) from the support bracket.
[Rev.10 from 2021] 2026.04.02 06:18:16 UTC