W DOC AIRBUS | AMM A320F

Removal of the Magnetic Level-Indicator Upper-Housing


TASK 28-43-23-000-004-A
Removal of the Magnetic Level-Indicator Upper-Housing


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
FIN: 98QM
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
SAFETY BARRIER(S)
No specific
AR
WARNING NOTICE(S)
460005835
1
SLEEVE - GROUND LOCK
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
191JB, 195BB, 196BB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 21-52-22-000-001-A
Removal of the Fan Plenum Chamber
TASK 28-10-00-910-001-A
Safety Procedures When You Do Work in a Fuel Tank
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 28-25-00-650-001-A
Pressure Defuel
TASK 28-25-00-650-003-A
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 28-25-00-650-003-A-01
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 28-43-23-000-001-A
Removal of the Magnetic Level-Indicator Rod
TASK 28-43-23-000-002-A
Removal of the Magnetic Level-Indicator Lower-Housing
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 57-17-11-000-001-A
Removal of Access Cover 147AZ(148AZ)
TASK 57-17-11-000-001-B
Removal of Access Cover 148AZ or/and the ACT-Equipment Support Door
3. Job Set-up
Subtask 28-43-23-941-059-A
A. Safety Precautions
WARNING: BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
   (1) You must obey the fuel safety procedures when you do work in a fuel tank (Ref. AMM TASK 28-10-00-910-001).
   (2) Put the SAFETY BARRIER(S) in position.
   (3) Put a WARNING NOTICE(S) in position to tell persons not to operate the landing gear and the related doors.
Subtask 28-43-23-650-054-A
B. Fuel Configuration
   (1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
   (2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-43-23-010-055-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the MLG doors (Ref. AMM TASK 32-12-00-010-001).
   (2) Make sure that the 460005835 SLEEVE - GROUND LOCK is on the MLG door actuating-cylinders.
   (3) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the access panels 147AZ and 148AZ.
   (4) Remove the center-tank access panels 147AZ and 148AZ (Ref. AMM TASK 57-17-11-000-001) and (Ref. AMM TASK 28-10-00-910-002).
   (5) Remove the access panels 191JB and 195BB and/or 196BB.
   (6) Remove the left-hand fan plenum-chamber, 10HM5 (Ref. AMM TASK 21-52-22-000-001).
   (7) Remove the MLI rod (92QM) from the MLI lower housing (91QM) (Ref. AMM TASK 28-43-23-000-001).
   (8) Remove the MLI lower housing (91QM) (Ref. AMM TASK 28-43-23-000-002).
Subtask 28-43-23-010-055-C ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the MLG doors (Ref. AMM TASK 32-12-00-010-001).
   (2) Make sure that the 460005835 SLEEVE - GROUND LOCK is on the MLG door actuating-cylinders.
   (3) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the access panel 148AZ and the ACT-Equipment Support Door.
   (4) Remove the center-tank access panel 148AZ and the ACT-Equipment Support Door (Ref. AMM TASK 57-17-11-000-001) and (Ref. AMM TASK 28-10-00-910-002).
   (5) Remove the access panels 191JB and 195BB and/or 196BB.
   (6) Remove the left-hand fan plenum-chamber, 10HM5 (Ref. AMM TASK 21-52-22-000-001).
   (7) Remove the MLI rod (92QM) from the MLI lower housing (91QM) (Ref. AMM TASK 28-43-23-000-001).
   (8) Remove the MLI lower housing (91QM) (Ref. AMM TASK 28-43-23-000-002).
4. Procedure
Subtask 28-43-23-020-057-A ** ON A/C NOT FOR ALL
A. Removal of the Magnetic Level-Indicator Upper-Housing 98QM
   (1) Remove the screws (3) and the washers (4) and carefully move apart the upper body (5) from the center body assembly (7).
   (2) Carefully remove the upper body (5) together with the float (2) from the support bracket (1).
   (3) Remove and discard the O-ring (6).
   (4) Remove sufficient bolts (15) from the vapor seal reinforcement (11) and the seal (12) to give access to the center body assembly (7).
   (5) Remove the nut (14), the washers (10) and (13) and the screw (9), then remove the bonding strap (8) from the vapor seal edge-reinforcement.
   (6) Remove the screws (17) and the washers (18) and remove the backing seal plates (16) and (19).
   (7) Carefully remove the center body assembly (7) from the vapor seal membrane.
   (8) Remove and discard the O-ring (20).
Subtask 28-43-23-020-057-C ** ON A/C NOT FOR ALL
A. Removal of the Magnetic Level-Indicator Upper-Housing 98QM
   (1) Remove the screw (23), the washer (22) and the bonding strap (21) from the upper body (5).
   (2) Remove the screws (3) and the washers (4) and carefully move apart the upper body (5) from the center body assembly (7).
   (3) Carefully remove the upper body (5) together with the float (2) from the support bracket (1).
   (4) Remove and discard the O-ring (6).
   (5) Remove sufficient bolts (15) from the vapor seal reinforcement (11) and the seal (12) to give access to the center body assembly (7).
   (6) Remove the nut (14), the washers (10) and (13) and the screw (9), then remove the bonding strap (8) from the vapor seal edge-reinforcement.
   (7) Remove the screws (17) and the washers (18) and remove the backing seal plates (16) and (19).
   (8) Carefully remove the center body assembly (7) from the vapor seal membrane.
   (9) Remove and discard the O-ring (20).
[Rev.10 from 2021] 2026.04.02 06:18:14 UTC