Removal of the Magnetic Level-Indicator Rod
TASK 28-43-23-000-001-A
Removal of the Magnetic Level-Indicator Rod
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 28-43-23-941-057-A
Subtask 28-43-23-020-054-A
[Rev.10 from 2021]
2026.04.02 07:04:11 UTC
Removal of the Magnetic Level-Indicator Rod
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
FIN: 92QM
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY BARRIER(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
Subtask 28-43-23-941-057-A
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
4. ProcedureWARNING:
OBEY THE FUEL SAFETY PROCEDURES.
(1) You must obey the fuel safety procedures when you do work on the fuel system (Ref. AMM TASK 28-00-00-910-001). (2) Put the SAFETY BARRIER(S) in position.
Subtask 28-43-23-020-054-A
A. Removal of the Magnetic Level-Indicator Rod 92QM
(1) Push the Magnetic Level Indicator (MLI) rod (5) in against the spring (2) and turn it through 90 deg. to release.
(2) Pull the MLI rod (5) out until the magnet (1) touches the seal (3). Continue to pull until the MLI rod (5) is out of the MLI lower housing (4).
(1) Push the Magnetic Level Indicator (MLI) rod (5) in against the spring (2) and turn it through 90 deg. to release.
(2) Pull the MLI rod (5) out until the magnet (1) touches the seal (3). Continue to pull until the MLI rod (5) is out of the MLI lower housing (4).
Magnetic Level Indicator 92QM - Rod Detail