W DOC AIRBUS | AMM A320F

Removal of the Magnetic Level-Indicator Assembly


TASK 28-43-22-000-004-A
Removal of the Magnetic Level-Indicator Assembly


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
FIN: 202QM ** ON A/C NOT FOR ALL
FIN: 203QM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
1
SAFETY BARRIER(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [202QM] (HOUSING-MLI NO 7 LEFT)
540QB
FOR [203QM] (HOUSING-MLI NO 7 RIGHT)
640QB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 28-10-00-910-001-A
Safety Procedures When You Do Work in a Fuel Tank
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 28-25-00-650-001-A
Pressure Defuel
TASK 28-25-00-650-003-A
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 28-25-00-650-003-A-01
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 57-27-11-000-002-A
Removal of the Access Panel
CMM 284330
(for corrective action)
3. Job Set-up
Subtask 28-43-22-941-055-A ** ON A/C NOT FOR ALL
A. Safety Precautions
WARNING: BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
   (1) You must obey the fuel safety procedures when you do work in a fuel tank (Ref. AMM TASK 28-10-00-910-001).
   (2) Put the SAFETY BARRIER(S) in position.
Subtask 28-43-22-650-051-A ** ON A/C NOT FOR ALL
B. Fuel Configuration
   (1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
   (2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-43-22-010-051-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the applicable access panel 540QB (640QB).
   (2) Remove the applicable access panel (Ref. AMM TASK 57-27-11-000-002) and (Ref. AMM TASK 28-10-00-910-002):
     (a) FOR [202QM] (HOUSING-MLI NO 7 LEFT)
remove 540QB
     (b) FOR [203QM] (HOUSING-MLI NO 7 RIGHT)
remove 640QB.
4. Procedure
Subtask 28-43-22-020-053-B ** ON A/C NOT FOR ALL
A. Removal of the Magnetic Level-Indicator Assembly 202QM (203QM)
   (1) Remove the nuts (3) from the bolts (6).
   (2) Remove the bolts (6) from the magnetic level-indicator housing (2).
   (3) Remove the magnetic level-indicator assembly (7).
NOTE: If the MLI is removed with a loose or damaged top-stop (8), refer to CMM 284330 for repair instructions.
   (4) Remove and discard the O-ring seals (4) and (5).
[Rev.10 from 2021] 2026.04.02 06:18:13 UTC