Removal of the Magnetic Level-Indicator Rod
TASK 28-43-22-000-003-A
Removal of the Magnetic Level-Indicator Rod
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 28-43-22-941-054-A ** ON A/C NOT FOR ALL
Subtask 28-43-22-020-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:18:13 UTC
Removal of the Magnetic Level-Indicator Rod
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
Subtask 28-43-22-941-054-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
Subtask 28-43-22-010-054-A ** ON A/C NOT FOR ALL WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
(1) You must obey the fuel safety procedures when you do work on the fuel system (Ref. AMM TASK 28-00-00-910-001). (2) Put the SAFETY BARRIER(S) in position.
B. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) in position under the applicable Magnetic-Level-Indicator (MLI) rod (2).
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT) in position under the applicable Magnetic-Level-Indicator (MLI) rod (2).
Subtask 28-43-22-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the Magnetic-Level-Indicator Rod 206QM (207QM)
(1) Push the MLI rod (2) in against the spring (4) and turn through 90 deg. to release.
(2) Pull the MLI rod (2) out until the magnet (1) touches the seal (3). Continue to pull until the MLI rod is out of the housing.
(1) Push the MLI rod (2) in against the spring (4) and turn through 90 deg. to release.
(2) Pull the MLI rod (2) out until the magnet (1) touches the seal (3). Continue to pull until the MLI rod is out of the housing.
Magnetic-Level-Indicator Rod