Installation of the Center Tank Fuel Quantity Indicating Probe Fused Adapters
TASK 28-42-44-400-003-A
Installation of the Center Tank Fuel Quantity Indicating Probe Fused Adapters
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 28-42-44-941-056-A ** ON A/C NOT FOR ALL
Subtask 28-42-44-420-055-A ** ON A/C NOT FOR ALL
Subtask 28-42-44-410-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:18:11 UTC
Installation of the Center Tank Fuel Quantity Indicating Probe Fused Adapters
WARNING:
MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING NOTICES ARE IN POSITION.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-42-00-740-001-A | Status Report (BITE) |
| TASK 28-46-00-740-001-A | Functional (BITE) Test |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
Subtask 28-42-44-941-056-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Make sure that the SAFETY BARRIER(S) are in position.
Subtask 28-42-44-860-052-A ** ON A/C NOT FOR ALL (1) Make sure that the SAFETY BARRIER(S) are in position.
B. Aircraft Maintenance Configuration
(1) Make sure the ACCESS PLATFORM 3M (10 FT) is in position below zone 142.
(2) Make sure that the 460005835 SLEEVE - GROUND LOCK is on the applicable MLG door actuating-cylinder.
Subtask 28-42-44-865-056-A ** ON A/C NOT FOR ALL (1) Make sure the ACCESS PLATFORM 3M (10 FT) is in position below zone 142.
(2) Make sure that the 460005835 SLEEVE - GROUND LOCK is on the applicable MLG door actuating-cylinder.
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FUEL/FQI/CHAN/1 | 1QT | A13 |
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L26 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L25 |
| 121VU | FUEL/FQI/CHAN/2 | 2QT | M27 |
Subtask 28-42-44-420-055-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
(1) Clean the component interface and/or the adjacent area with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(2) Do an inspection of the component interfaces and the adjacent area.
Subtask 28-42-44-420-056-A ** ON A/C NOT FOR ALL (1) Clean the component interface and/or the adjacent area with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(2) Do an inspection of the component interfaces and the adjacent area.
B. Installation of the Fused Adapters
(1) Remove the blanking caps from the electrical connectors.
(2) Install the fused adapters (2) in the center tank connectors (3).
(3) Connect the wiring connectors (1) to the fused adapters (2).
Subtask 28-42-44-865-057-A ** ON A/C NOT FOR ALL (1) Remove the blanking caps from the electrical connectors.
(2) Install the fused adapters (2) in the center tank connectors (3).
(3) Connect the wiring connectors (1) to the fused adapters (2).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 28-42-44-740-054-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FUEL/FQI/CHAN/1 | 1QT | A13 |
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L26 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L25 |
| 121VU | FUEL/FQI/CHAN/2 | 2QT | M27 |
D. Test
(1) Do a status report (BITE) of the fuel-quantity indicating system (Ref. AMM TASK 28-42-00-740-001).
(2) Do a functional (BITE) test of the fuel-tank level-sensing system (Ref. AMM TASK 28-46-00-740-001).
5. Close-up(1) Do a status report (BITE) of the fuel-quantity indicating system (Ref. AMM TASK 28-42-00-740-001).
(2) Do a functional (BITE) test of the fuel-tank level-sensing system (Ref. AMM TASK 28-46-00-740-001).
Subtask 28-42-44-410-054-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the MLG doors (Ref. AMM TASK 32-12-00-410-001).
Subtask 28-42-44-942-055-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the MLG doors (Ref. AMM TASK 32-12-00-410-001).
B. Removal of Equipment
(1) Remove the safety barriers.
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the safety barriers.
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Centre Tank Fuel Quantity Indicating Probe Fused Adapters - Location and Detail