Removal of the Center Tank Fuel Quantity Indicating Probe Fused Adapters
TASK 28-42-44-000-003-A
Removal of the Center Tank Fuel Quantity Indicating Probe Fused Adapters
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 28-42-44-941-055-A ** ON A/C NOT FOR ALL
Subtask 28-42-44-020-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:18:11 UTC
Removal of the Center Tank Fuel Quantity Indicating Probe Fused Adapters
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
Subtask 28-42-44-941-055-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Put a WARNING NOTICE(S) in position to tell persons not to operate the MLG doors.
Subtask 28-42-44-865-055-A ** ON A/C NOT FOR ALL (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Put a WARNING NOTICE(S) in position to tell persons not to operate the MLG doors.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 28-42-44-010-054-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FUEL/FQI/CHAN/1 | 1QT | A13 |
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L26 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L25 |
| 121VU | FUEL/FQI/CHAN/2 | 2QT | M27 |
C. Get Access
(1) Open the MLG doors and install the safety devices (Ref. AMM TASK 32-12-00-010-001).
(2) Make sure that the 460005835 SLEEVE - GROUND LOCK is on the applicable MLG door actuating-cylinder.
(3) Put the ACCESS PLATFORM 3M (10 FT) in position below zone 142.
4. Procedure(1) Open the MLG doors and install the safety devices (Ref. AMM TASK 32-12-00-010-001).
(2) Make sure that the 460005835 SLEEVE - GROUND LOCK is on the applicable MLG door actuating-cylinder.
(3) Put the ACCESS PLATFORM 3M (10 FT) in position below zone 142.
Subtask 28-42-44-020-053-A ** ON A/C NOT FOR ALL
A. Removal of the Fused Adapters
(1) Disconnect the wiring connectors (1) from the fused adapters (2).
(2) Remove the fused adapters (2) from the center tank connectors (3).
(3) Put CAP - BLANKING on the disconnected electrical connectors.
(1) Disconnect the wiring connectors (1) from the fused adapters (2).
(2) Remove the fused adapters (2) from the center tank connectors (3).
(3) Put CAP - BLANKING on the disconnected electrical connectors.
Centre Tank Fuel Quantity Indicating Probe Fused Adapters - Location and Detail