Installation of the Wing Tank Fuel Quantity Indicating Probe Fused/Shorting Plug Connectors
TASK 28-42-43-400-008-A
Installation of the Wing Tank Fuel Quantity Indicating Probe Fused/Shorting Plug Connectors
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 28-42-43-941-066-A
Subtask 28-42-43-420-099-A
Subtask 28-42-43-410-064-A
[Rev.10 from 2021]
2026.04.02 06:18:10 UTC
Installation of the Wing Tank Fuel Quantity Indicating Probe Fused/Shorting Plug Connectors
WARNING:
MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING NOTICES ARE IN POSITION.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 574BB, 674BB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-42-00-740-001-A | Status Report (BITE) |
| TASK 28-46-00-740-001-A | Functional (BITE) Test |
Wing Tank Fuel Quantity Indicating Probe Fused Plug Connectors - Location and Detail ** ON A/C NOT FOR ALL | |
Wing Tank Fuel Quantity Indicating Probe Shorting Plug Connectors - Location and Detail ** ON A/C NOT FOR ALL | |
Subtask 28-42-43-941-066-A
A. Safety Precautions
(1) Make sure that the SAFETY BARRIER(S) are in position.
Subtask 28-42-43-860-056-A (1) Make sure that the SAFETY BARRIER(S) are in position.
B. Aircraft Maintenance Configuration
(1) Make sure that the ACCESS PLATFORM 3M (10 FT) is below the applicable wing trailing edge at the false rear spar, zone 574(674).
(2) Make sure that the applicable access panel is open:
Subtask 28-42-43-865-072-A (1) Make sure that the ACCESS PLATFORM 3M (10 FT) is below the applicable wing trailing edge at the false rear spar, zone 574(674).
(2) Make sure that the applicable access panel is open:
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FUEL/FQI/CHAN/1 | 1QT | A13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L26 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L25 |
| ** ON A/C ALL | |||
| 121VU | FUEL/FQI/CHAN/2 | 2QT | M27 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L25 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L24 |
Subtask 28-42-43-420-099-A
A. Preparation for Installation
(1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Clean the component interface and/or the adjacent area with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(3) Do an inspection of the component interfaces and the adjacent area.
Subtask 28-42-43-420-100-A ** ON A/C NOT FOR ALL (1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Clean the component interface and/or the adjacent area with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(3) Do an inspection of the component interfaces and the adjacent area.
B. Installation of the Fused Plug Connectors
(1) Remove the blanking caps from the electrical connectors.
(2) Install the fused plug connectors (1) on the harness connectors (5).
(3) Attach the lanyards (2) to the support bracket with the screws (3) and the nuts (4).
Subtask 28-42-43-420-100-B ** ON A/C NOT FOR ALL (1) Remove the blanking caps from the electrical connectors.
(2) Install the fused plug connectors (1) on the harness connectors (5).
(3) Attach the lanyards (2) to the support bracket with the screws (3) and the nuts (4).
B. Installation of the Shorting Plug Connectors
(1) Remove the blanking caps from the electrical connectors.
(2) Install the shorting plug connectors (1) on the harness connectors (5).
(3) Attach the lanyards (2) to the support bracket with the screws (3) and the nuts (4).
Subtask 28-42-43-865-073-A (1) Remove the blanking caps from the electrical connectors.
(2) Install the shorting plug connectors (1) on the harness connectors (5).
(3) Attach the lanyards (2) to the support bracket with the screws (3) and the nuts (4).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 28-42-43-740-058-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FUEL/FQI/CHAN/1 | 1QT | A13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L26 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L25 |
| ** ON A/C ALL | |||
| 121VU | FUEL/FQI/CHAN/2 | 2QT | M27 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L25 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L24 |
D. Test
(1) Do a status report (BITE) of the fuel-quantity indicating system (Ref. AMM TASK 28-42-00-740-001).
(2) Do a functional (BITE) test of the fuel-tank level-sensing system (Ref. AMM TASK 28-46-00-740-001).
5. Close-up(1) Do a status report (BITE) of the fuel-quantity indicating system (Ref. AMM TASK 28-42-00-740-001).
(2) Do a functional (BITE) test of the fuel-tank level-sensing system (Ref. AMM TASK 28-46-00-740-001).
Subtask 28-42-43-410-064-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the applicable access panel:
Subtask 28-42-43-942-057-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the applicable access panel:
B. Removal of Equipment
(1) Remove the safety barriers.
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the safety barriers.
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Wing Tank Fuel Quantity Indicating Probe Fused Plug Connectors - Location and Detail