W DOC AIRBUS | AMM A320F

Removal of the Fuel Quantity-Indicating Computer (FQIC) On Board Removable Memory


TASK 28-42-34-000-002-A
Removal of the Fuel Quantity-Indicating Computer (FQIC) On Board Removable Memory


FIN: 3QT ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
811
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
3. Job Set-up
Subtask 28-42-34-861-051-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 28-42-34-865-053-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFUEL/FQI/CHAN/11QTA13
** ON A/C NOT FOR ALL
121VUFUEL/FQI/CHANNEL/1 AND 28QTL26
** ON A/C NOT FOR ALL
121VUFUEL/FQI/CHAN/22QTM27
** ON A/C NOT FOR ALL
121VUFUEL/FQI/CHANNEL/1 AND 28QTL25
Subtask 28-42-34-010-051-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 811.
   (2) Open access door 811.
4. Procedure
Subtask 28-42-34-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the FQIC (3QT)
   (1) Loosen the knurled nuts (3).
   (2) Remove the FQIC (4) from its rack.
   (3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
Subtask 28-42-34-020-052-A ** ON A/C NOT FOR ALL
B. Removal of the FQIC OBRM (3QT1)
   (1) Loosen the screws (6) on the front of the FQIC (3QT).
   (2) Remove the OBRM module (7).