Removal of the Fuel Quantity-Indicating Computer (FQIC)
TASK 28-42-34-000-001-A
Removal of the Fuel Quantity-Indicating Computer (FQIC)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-42-34-861-050-A Subtask 28-42-34-865-050-A
Subtask 28-42-34-020-050-A
[Rev.10 from 2021]
2026.04.02 06:18:08 UTC
Removal of the Fuel Quantity-Indicating Computer (FQIC)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 122 | AVIONICS COMPARTMENT |
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
Subtask 28-42-34-861-050-A Subtask 28-42-34-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 28-42-34-010-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FUEL/FQI/CHAN/1 | 1QT | A13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L26 |
| ** ON A/C ALL | |||
| 121VU | FUEL/FQI/CHAN/2 | 2QT | M27 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L25 |
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 811.
(2) Open the access door 811.
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 811.
(2) Open the access door 811.
Subtask 28-42-34-020-050-A
A. Removal of the FQIC (3QT)
(1) Loosen the knurled nuts (3).
(2) Remove the FQIC (4) from its rack (2).
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(1) Loosen the knurled nuts (3).
(2) Remove the FQIC (4) from its rack (2).
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
Fuel Quantity-Indicating Computer (FQIC)