W DOC AIRBUS | AMM A320F

Removal of the Fuel Quantity Probe of the ACT


TASK 28-42-24-000-001-A
Removal of the Fuel Quantity Probe of the ACT


WARNING: BE CAREFUL NOT TO GET AIRCRAFT FUEL IN YOUR MOUTH OR IN YOUR EYES. IF YOU GET FUEL ON YOUR SKIN OR ON YOUR CLOTHES, FLUSH IT IMMEDIATELY WITH WATER. IF NECESSARY, GET MEDICAL HELP. AIRCRAFT FUEL IS POISONOUS.
WARNING: DO NOT GET YOUR CLOTHES SOAKED WITH FUEL.
WARNING: MAKE SURE THAT YOU HAVE THE CORRECT FIRE FIGHTING EQUIPMENT AVAILABLE.
WARNING: OBEY THE FUEL SAFETY PROCEDURES.
FIN: 21QT1 ** ON A/C NOT FOR ALL
FIN: 21QT2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 28-00-00-910-001-A
Fuel Safety Procedures
TASK 28-25-00-650-001-A
Pressure Defuel
TASK 28-25-00-650-005-A
To Drain the Remaining Fuel from the Additional Center Tank (ACT)
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 53-42-12-000-001-A
Removal of the Cabin Floor Panels from FR47 thru FR64
TASK 53-42-14-000-001-A
Removal of the Aft Cargo-Compartment Floor-Panels Zone 150
F Fuel Quantity Probe of the ACT ** ON A/C NOT FOR ALL
F Fuel Quantity Probe of the ACT ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 28-42-24-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
   (2) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
   (3) Open the aft cargo compartment door (Ref. AMM TASK 52-30-00-860-001).
   (4) Put an ACCESS PLATFORM 2M (6 FT) in position at the opening of the AFT cargo compartment door.
   (5) Transfer the fuel from the Additional Center Tank (ACT) to the center tank (Ref. AMM TASK 28-25-00-650-001).
   (6) Drain the remaining fuel of the ACT (Ref. AMM TASK 28-25-00-650-005).
   (7) Put the WARNING NOTICE(S) in position on:
- the refuel/defuel panel 801VU,
- the fuel panel 40VU,
to tell persons not to operate the refuel/defuel system.
Subtask 28-42-24-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUACT1/REFUEL & SPLY33QUL29
121VUFUEL/HI/LVL/SPLY1QJL25
121VUFUEL/RFL/DFL/SPLY2QUL24
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL23
121VUACT XFR VALVE MAN CTL30QHN29
121VUACT1/CTL & SPLY9QHP29
121VUACT PUMP SUPPLY25QHQ29
Subtask 28-42-24-010-051-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Remove the access panel 251MG and 252MG in the floor panels 252BG and 251BG in the passenger compartment to get access to the fuel probes (Ref. AMM TASK 53-42-12-000-001).
   (2) Remove the access panels 151LC and 151MC in the ceiling of t he AFT cargo compartment (Ref. AMM TASK 53-42-14-000-001).
Subtask 28-42-24-010-051-C ** ON A/C NOT FOR ALL
C. Get Access with Two Additional Center Tanks (ACT) Installed
   (1) For the ACT 1 (FWD):
     (a) In the passenger compartment, remove the carpet over the floor panels 252BG and 251BG.
     (b) Remove the access panels 251MG and 252MG in the floor panels 251BG and 252BG in the passenger compartment to get access to the fuel probes (Ref. AMM TASK 53-42-12-000-001).
     (c) Remove the access panels 151LC and 151MC in the ceiling of the AFT cargo compartment (Ref. AMM TASK 53-42-14-000-001).
   (2) For the ACT 2 (AFT):
     (a) In the passenger compartment, remove the carpet over the floor panels 251BF and 252BF.
     (b) Remove the access panels 251NG and 252NG in the floor panels 251BF and 252BF in the passenger compartment to get access to the fuel probes (Ref. AMM TASK 53-42-12-000-001).
     (c) Remove the access panels 151QC and 151PC in the ceiling of the AFT cargo compartment (Ref. AMM TASK 53-42-14-000-001).
4. Procedure
Subtask 28-42-24-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Fuel Quantity Indicator Probe
   (1) Disconnect the electrical connector (13) from the receptacle (15).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove the screw (17), the washer (16) and the bonding strap (4) from the flange (14) of the fuel probe (8).
   (4) Remove the screws (2) and the washers (3) from the flange (14) of the fuel probe (8).
   (5) Carefully pull the fuel probe (8) out of the duct (10) of the ACT (1) and up through the passenger compartment floor.
   (6) Remove and discard the O-ring (12) of the fuel probe (8).
   (7) Remove and discard the O-ring (11) from the flange (9) of the duct (10).
Subtask 28-42-24-020-050-B ** ON A/C NOT FOR ALL
A. Removal of the Fuel Quantity Indicator Probe with Two ACT Installed
NOTE: The subsequent procedure is the same for each ACT. Therefore only one ACT is given. Differences between each ACT are given where applicable.
   (1) Disconnect the electrical connector (13) from the receptacle (15).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove the screw (17), the washer (16) and the bonding strap (4) from the flange (14) of the fuel probe (8).
   (4) Remove the screws (2) and the washers (3) from the flange (14) of the fuel probe (8).
   (5) Carefully pull the fuel probe (8) out of the duct (10) of the ACT (1) and up through the passenger compartment floor.
   (6) Remove and discard the O-ring (12) of the fuel probe (8).
   (7) Remove and discard the O-ring (11) from the flange (9) of the duct (10).