Removal of the Center (Transfer) Tank Fuel-Quantity Probes
TASK 28-42-15-000-004-A
Removal of the Center (Transfer) Tank Fuel-Quantity Probes
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 28-42-15-941-062-A ** ON A/C NOT FOR ALL
Subtask 28-42-15-020-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:11:16 UTC
Removal of the Center (Transfer) Tank Fuel-Quantity Probes
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 35QT ** ON A/C NOT FOR ALL
FIN: 36QT ** ON A/C NOT FOR ALL
FIN: 37QT ** ON A/C NOT FOR ALL
FIN: 38QT ** ON A/C NOT FOR ALL
FIN: 51QT ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 36QT ** ON A/C NOT FOR ALL
FIN: 37QT ** ON A/C NOT FOR ALL
FIN: 38QT ** ON A/C NOT FOR ALL
FIN: 51QT ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 28-25-00-650-003-A | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-650-003-A-01 | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 57-17-11-000-001-A | Removal of Access Cover 147AZ(148AZ) |
| TASK 57-17-11-000-001-B | Removal of Access Cover 148AZ or/and the ACT-Equipment Support Door |
Subtask 28-42-15-941-062-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
(3) Put a WARNING NOTICE(S) in position to tell persons not to operate the MLG doors.
Subtask 28-42-15-650-055-A ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
(1) You must obey the fuel safety procedures (Ref. AMM TASK 28-10-00-910-001) when you do work in a fuel tank. (2) Put the SAFETY BARRIER(S) in position.
(3) Put a WARNING NOTICE(S) in position to tell persons not to operate the MLG doors.
B. Aircraft Maintenance Configuration
(1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-42-15-865-059-A ** ON A/C NOT FOR ALL (1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 28-42-15-010-057-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FUEL/FQI/CHAN/1 | 1QT | A13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L26 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/FQI/CHAN/2 | 2QT | M27 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L25 |
D. Get Access
(2) Make sure that the 460005835 SLEEVE - GROUND LOCK is installed on the applicable MLG door actuator(s).
(3) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the applicable access panel 147AZ (148AZ).
(4) Remove the applicable access panel 147AZ (148AZ) (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-17-11-000-001).
Subtask 28-42-15-010-057-B ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE LANDING GEAR DOORS ARE CLEAR.
(1) Open the applicable MLG door(s) (Ref. AMM TASK 32-12-00-010-001). (2) Make sure that the 460005835 SLEEVE - GROUND LOCK is installed on the applicable MLG door actuator(s).
(3) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the applicable access panel 147AZ (148AZ).
(4) Remove the applicable access panel 147AZ (148AZ) (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-17-11-000-001).
D. Get Access
(2) Make sure that the 460005835 SLEEVE - GROUND LOCK is installed on the applicable MLG door actuator(s).
(3) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the applicable access panel 148AZ and/or the ACT Equipment Support Door.
(4) Remove the applicable access panel 148AZ and/or the ACT Equipment Support Door (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-17-11-000-001).
4. ProcedureWARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE LANDING GEAR DOORS ARE CLEAR.
(1) Open the applicable MLG door(s) (Ref. AMM TASK 32-12-00-010-001). (2) Make sure that the 460005835 SLEEVE - GROUND LOCK is installed on the applicable MLG door actuator(s).
(3) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the applicable access panel 148AZ and/or the ACT Equipment Support Door.
(4) Remove the applicable access panel 148AZ and/or the ACT Equipment Support Door (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-17-11-000-001).
Subtask 28-42-15-020-059-A ** ON A/C NOT FOR ALL
A. Removal of the Center (Transfer) Tank Fuel-Quantity Probe
Center (Transfer) Tank Probes - Location and Detail ** ON A/C NOT FOR ALL
Center (Transfer) Tank Probes - Location and Detail ** ON A/C NOT FOR ALL
(2) Loosen the terminal screw (7) on the terminal block (2).
(3) Loosen the screws (3), (4) and (5) on the terminal block (2).
(4) Identify and remove the electrical connectors of the cable (8).
(5) Put CAP - BLANKING on the disconnected electrical connectors.
(6) Remove the bolts (9) and (12).
(7) Remove the probe (10).
(8) Remove the bracket (11) from the probe (10).
Center (Transfer) Tank Probes - Location and Detail ** ON A/C NOT FOR ALL
Center (Transfer) Tank Probes - Location and Detail ** ON A/C NOT FOR ALL CAUTION:
MAKE MATCH MARKS ON ALL THE ELECTRICAL WIRES BEFORE YOU DISCONNECT THEM. INCORRECT CONNECTION OF WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
(1) Remove and discard the cable ties (1) to release the electrical cable (8) from the probe (10). (2) Loosen the terminal screw (7) on the terminal block (2).
(3) Loosen the screws (3), (4) and (5) on the terminal block (2).
(4) Identify and remove the electrical connectors of the cable (8).
(5) Put CAP - BLANKING on the disconnected electrical connectors.
(6) Remove the bolts (9) and (12).
(7) Remove the probe (10).
(8) Remove the bracket (11) from the probe (10).