ECAM Fuel Page Indication Additional Center Tank(s) - Reactivation
TASK 28-40-00-440-003-A
ECAM Fuel Page Indication Additional Center Tank(s) - Reactivation
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-40-00-941-070-A ** ON A/C NOT FOR ALL
Subtask 28-40-00-440-052-A ** ON A/C NOT FOR ALL
Subtask 28-40-00-860-074-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:18:03 UTC
ECAM Fuel Page Indication Additional Center Tank(s) - Reactivation
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY BARRIER(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 192MB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
Subtask 28-40-00-941-070-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 28-40-00-010-063-A ** ON A/C NOT FOR ALL Subtask 28-40-00-860-073-A ** ON A/C NOT FOR ALL WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
(1) You must obey the fuel safety procedures when you do work on the fuel system (Ref. AMM TASK 28-00-00-910-001). (2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
C. Aircraft Maintenance Configuration
(1) If the applicable ACT was refueled with a known quantity of fuel, continue as follows:
(a) On panel 801VU:
(a) On panel 801VU:
4. Procedure(1) If the applicable ACT was refueled with a known quantity of fuel, continue as follows:
(a) On panel 801VU:
- make sure that the applicable ACT REFUEL VALVE switch is in the NORM position and the guard is lowered.
(a) On panel 801VU:
- remove the warning notice from the applicable ACT REFUEL VALVE switch
- put the applicable ACT REFUEL VALVE switch in the NORM position and lower the guard.
Subtask 28-40-00-440-052-A ** ON A/C NOT FOR ALL
A. Reactivation of the normal ECAM fuel page indication for the applicable ACT.
(1) If you do not know the cause of the malfunction, trouble-shoot the system and do the corrective action (Ref. TSM Chapter 28-42).
5. Close-up(1) If you do not know the cause of the malfunction, trouble-shoot the system and do the corrective action (Ref. TSM Chapter 28-42).
Subtask 28-40-00-860-074-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make an entry in the aircraft technical log that the ECAM fuel quantity indication for applicable ACT is now serviceable.
Subtask 28-40-00-410-061-A ** ON A/C NOT FOR ALL (1) Make an entry in the aircraft technical log that the ECAM fuel quantity indication for applicable ACT is now serviceable.
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) On panel 801VU:
Subtask 28-40-00-942-068-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) On panel 801VU:
- make sure that the applicable ACT REFUEL VALVE switch is in the NORM and guarded position.
C. Removal of Equipment
(1) Remove the safety barriers.
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the safety barriers.
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.