Low Level Detection System in Additional Center Tank(s) (If Installed) - Deactivation
TASK 28-40-00-040-011-A
Low Level Detection System in Additional Center Tank(s) (If Installed) - Deactivation
Introduce maintenance procedure to check that there is no fuel in ACT 2.
This deactivation task is not related to an AFM-CDL/MMEL item.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-40-00-941-068-A ** ON A/C NOT FOR ALL
Subtask 28-40-00-040-083-A ** ON A/C NOT FOR ALL
Subtask 28-40-00-860-070-A ** ON A/C NOT FOR ALL
[Rev.9 from 2019]
2026.04.02 06:18:04 UTC
Low Level Detection System in Additional Center Tank(s) (If Installed) - Deactivation
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Introduce maintenance procedure to check that there is no fuel in ACT 2.
This deactivation task is not related to an AFM-CDL/MMEL item.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 192MB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-11-28-650-004-A | Pressure Refuel with Manual Control |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 28-25-00-650-005-A | To Drain the Remaining Fuel from the ACT |
| TASK 28-25-00-869-001-A | Fuel Transfer |
Subtask 28-40-00-941-068-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 28-40-00-010-061-A ** ON A/C NOT FOR ALL Subtask 28-40-00-860-069-A ** ON A/C NOT FOR ALL WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
(1) You must obey the fuel safety procedures when you do work on the fuel system (Ref. AMM TASK 28-00-00-910-001). (2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
C. Aircraft Maintenance Configuration
(1) Move the fuel from the ACT 2 into the center tank (Ref. AMM TASK 28-25-00-869-001).
4. Procedure(1) Move the fuel from the ACT 2 into the center tank (Ref. AMM TASK 28-25-00-869-001).
NOTE: Act 2 will contain a small quantity of unusable fuel after:
(2) Drain the remaining fuel from the ACT 2 (Ref. AMM TASK 28-25-00-650-005). - the contents have been used in flight
- the contents have been moved to the center tank when the aircraft is on the ground.
Subtask 28-40-00-040-083-A ** ON A/C NOT FOR ALL
A. Fuel Configuration
(1) On panel 801VU, lift the guard and put the ACT 2 REFUEL VALVE switch in the SHUT position.
(2) Refuel the other fuel tanks to the necessary quantity (Ref. AMM TASK 12-11-28-650-004).
(3) Repeat the procedure to drain the remaining fuel from the ACT 2 (Ref. AMM TASK 28-25-00-650-005) to make sure that the ACT 2 stays empty after refuel.
5. Close-up(1) On panel 801VU, lift the guard and put the ACT 2 REFUEL VALVE switch in the SHUT position.
(2) Refuel the other fuel tanks to the necessary quantity (Ref. AMM TASK 12-11-28-650-004).
(3) Repeat the procedure to drain the remaining fuel from the ACT 2 (Ref. AMM TASK 28-25-00-650-005) to make sure that the ACT 2 stays empty after refuel.
NOTE: The ACT 2 must not contain any fuel. It must stay empty after the other tanks have been refueled.
Subtask 28-40-00-860-070-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Put a WARNING NOTICE(S) in position to tell the flight crew that the low level sensors in the ACT 2, are unserviceable.
(2) Make a note in the aircraft technical log:
Subtask 28-40-00-410-059-A ** ON A/C NOT FOR ALL (1) Put a WARNING NOTICE(S) in position to tell the flight crew that the low level sensors in the ACT 2, are unserviceable.
(2) Make a note in the aircraft technical log:
- that the ACT 2 is empty of fuel
- the low level sensors in the ACT 2 are unserviceable.
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) On panel 801VU:
Subtask 28-40-00-942-066-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) On panel 801VU:
- make sure that the ACT 2 REFUEL VALVE switch is in the SHUT position
- attach a WARNING NOTICE(S) to the ACT 2 REFUEL VALVE switch. This is to tell personnel not to use the switch in the NORM or OPEN positions.
C. Removal of Equipment
(1) Remove the safety barriers.
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the safety barriers.
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.