Transfer Valve Indication - Intercell Transfer
TASK 28-40-00-040-004-A
Transfer Valve Indication - Intercell Transfer
MMEL 28-07-04-04A
WING TRANSFER VALVE INDICATION ON THE FUEL SD PAGE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-40-00-941-060-A ** ON A/C NOT FOR ALL
Subtask 28-40-00-040-055-A ** ON A/C NOT FOR ALL
Subtask 28-40-00-860-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:18:03 UTC
Transfer Valve Indication - Intercell Transfer
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Task Summary
1. Reason for the Job| Access | Test | Specific Tools | Mhr | E/T | Nb Men |
|---|---|---|---|---|---|
| YES | YES | NO | 0.3 | 0.3 | 1 |
MMEL 28-07-04-04A
WING TRANSFER VALVE INDICATION ON THE FUEL SD PAGE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY BARRIER(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 622KB | |
| 192MB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-11-28-650-003-A | Pressure Refuel with Automatic Control |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 28-25-00-869-001-A | Fuel Transfer |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 28-40-00-941-060-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
Subtask 28-40-00-010-056-A ** ON A/C NOT FOR ALL WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
(1) You must obey the fuel safety procedures when you do work on the fuel system (Ref. AMM TASK 28-00-00-910-001). (2) Put the SAFETY BARRIER(S) in position.
B. Get Access
(1) Open the access door 192MB.
Subtask 28-40-00-010-056-B ** ON A/C NOT FOR ALL (1) Open the access door 192MB.
NOTE: If operating in battery power, do not keep the door open longer than necessary because the battery can discharge.
B. Get Access
(1) Open the access door 622KB.
Subtask 28-40-00-861-053-A ** ON A/C NOT FOR ALL (1) Open the access door 622KB.
NOTE: If operating in battery power, do not keep the door open longer than necessary because the battery can discharge.
C. Energize the Electrical Circuits
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 28-40-00-650-052-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
D. Fuel Configuration
(1) Refuel, defuel or transfer fuel as necessary (Ref. AMM TASK 12-11-28-650-003), (Ref. AMM TASK 28-25-00-650-001), (Ref. AMM TASK 28-25-00-869-001) to get:
Subtask 28-40-00-860-054-A ** ON A/C NOT FOR ALL (1) Refuel, defuel or transfer fuel as necessary (Ref. AMM TASK 12-11-28-650-003), (Ref. AMM TASK 28-25-00-650-001), (Ref. AMM TASK 28-25-00-869-001) to get:
- a minimum of 900 kg (1980 lbs) to a maximum of 4000 kg (8820 lbs) in the inner cell of each wing tank
- maximum fuel in the outer cell of each wing tank.
E. Aircraft Maintenance Configuration
(1) Do the EIS start procedure (ECAM only) (Ref. AMM TASK 31-60-00-860-001).
(2) On the panel 11VU, push (in) the FUEL P/BSW.
(3) On the panel 800VU:
Subtask 28-40-00-865-056-A ** ON A/C NOT FOR ALL (1) Do the EIS start procedure (ECAM only) (Ref. AMM TASK 31-60-00-860-001).
(2) On the panel 11VU, push (in) the FUEL P/BSW.
(3) On the panel 800VU:
- set the MODE SELECT SWITCH to the REFUEL.
NOTE: It is necessary in this test to transfer fuel from the outer cell of each wing tank to its related inner cell.
F. Table of the circuit breakers used in this procedure:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FUEL/XFR VALVE1/WING/R | 2QP | A11 |
| 49VU | FUEL/XFR VALVE1/WING/L | 1QP | A10 |
| 121VU | FUEL/XFR VALVE2/WING/R | 4QP | M23 |
| 121VU | FUEL/XFR VALVE2/WING/L | 3QP | M22 |
Subtask 28-40-00-040-055-A ** ON A/C NOT FOR ALL
A. Transfer Valve Indication - Intercell Transfer
(1) Do this test:
5. Close-up(1) Do this test:
| ACTION | RESULT |
|---|---|
| 1.Open, safety clip and tag C/B 3QP | On the ECAM DU:
|
| 2.Remove the safety clip and the tag and close C/B 3QP | On the ECAM DU:
|
| 3.Open, safety clip and tag C/B 4QP | On the ECAM DU:
|
| 4.Remove the safety clip and the tag and close C/B 4QP | On the ECAM DU:
|
| 5.Open, safety clip and tag C/B 2QP | On the ECAM DU:
|
| 6.Remove the safety clip and the tag and close C/B 2QP | On the ECAM DU:
|
| 7.Open, safety clip and tag C/B 1QP | On the ECAM DU:
|
| 8.Remove the safety clip and the tag and close C/B 1QP | On the ECAM DU:
|
Subtask 28-40-00-860-055-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) On the panel 800VU:
(3) Make an applicable entry in the aircraft log.
Subtask 28-40-00-410-054-A ** ON A/C NOT FOR ALL (1) On the panel 800VU:
- set the MODE SELECT switch to the OFF position.
(3) Make an applicable entry in the aircraft log.
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 192MB.
Subtask 28-40-00-410-054-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 192MB.
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 622KB.
Subtask 28-40-00-650-053-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 622KB.
C. Fuel Configuration
(1) Refuel, defuel or transfer fuel as necessary (Ref. AMM TASK 12-11-28-650-003), (Ref. AMM TASK 28-25-00-650-001), (Ref. AMM TASK 28-25-00-869-001).
Subtask 28-40-00-862-053-A ** ON A/C NOT FOR ALL (1) Refuel, defuel or transfer fuel as necessary (Ref. AMM TASK 12-11-28-650-003), (Ref. AMM TASK 28-25-00-650-001), (Ref. AMM TASK 28-25-00-869-001).
D. De-energize the Electrical Circuits
(1) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
Subtask 28-40-00-942-058-A ** ON A/C NOT FOR ALL (1) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
E. Removal of Equipment
(1) Remove the safety barriers.
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the safety barriers.
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.