Crossfeed Valve Indication - Valve Operating Procedure
TASK 28-40-00-040-002-A
Crossfeed Valve Indication - Valve Operating Procedure
MMEL 28-07-04-03A
CROSSFEED VALVE INDICATION ON THE FUEL SD PAGE
MMEL 28-07-04-03B
CROSSFEED VALVE INDICATION ON THE FUEL SD PAGE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-40-00-941-058-A
Subtask 28-40-00-040-051-A
Subtask 28-40-00-410-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:18:03 UTC
Crossfeed Valve Indication - Valve Operating Procedure
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Task Summary
1. Reason for the Job| Access | Test | Specific Tools | Mhr | E/T | Nb Men |
|---|---|---|---|---|---|
| YES | YES | YES | 0.3 | 0.3 | 1 |
MMEL 28-07-04-03A
CROSSFEED VALVE INDICATION ON THE FUEL SD PAGE
MMEL 28-07-04-03B
CROSSFEED VALVE INDICATION ON THE FUEL SD PAGE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 622KB | |
| 192MB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
Subtask 28-40-00-941-058-A
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
Subtask 28-40-00-010-055-A ** ON A/C NOT FOR ALL WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
(1) You must obey the fuel safety procedures when you do work on the fuel system (Ref. AMM TASK 28-00-00-910-001). (2) Put the SAFETY BARRIER(S) in position.
B. Get Access
(1) Open the RH MLG door (Ref. AMM TASK 32-12-00-010-001).
(2) Make sure that the 460005835 SLEEVE - GROUND LOCK is installed on the applicable MLG door actuating-cylinder.
(3) Open the access door 192MB.
Subtask 28-40-00-010-055-B ** ON A/C NOT FOR ALL (1) Open the RH MLG door (Ref. AMM TASK 32-12-00-010-001).
(2) Make sure that the 460005835 SLEEVE - GROUND LOCK is installed on the applicable MLG door actuating-cylinder.
(3) Open the access door 192MB.
NOTE: If operating in battery power, do not keep the door open longer than necessary because the battery can discharge.
(4) Put an ACCESS PLATFORM 2M (6 FT) below the actuator 5QE of the fuel crossfeed valve 10QM. B. Get Access
(1) Open the RH MLG door (Ref. AMM TASK 32-12-00-010-001).
(2) Make sure that the 460005835 SLEEVE - GROUND LOCK is installed on the applicable MLG door actuating-cylinder.
(3) Open the access door 622KB.
Subtask 28-40-00-861-051-A (1) Open the RH MLG door (Ref. AMM TASK 32-12-00-010-001).
(2) Make sure that the 460005835 SLEEVE - GROUND LOCK is installed on the applicable MLG door actuating-cylinder.
(3) Open the access door 622KB.
NOTE: If operating in battery power, do not keep the door open longer than necessary because the battery can discharge.
(4) Put an ACCESS PLATFORM 2M (6 FT) below the actuator 5QE of the fuel crossfeed valve 10QM. C. Energize the Electrical Circuits
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 28-40-00-865-052-A (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
D. Table of the circuit breakers used in this procedure:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FUEL/X FEED/VALVE/MOT1 | 2QE | A12 |
| 121VU | FUEL/X FEED/VALVE/MOT2 | 1QE | M24 |
Subtask 28-40-00-040-051-A
A. Crossfeed Valve Indication - Valve Operating Procedure
(1) In the test that follows, on each operation of the crossfeed valve:
5. Close-up(1) In the test that follows, on each operation of the crossfeed valve:
- listen to the actuator and make sure it stops each time the crossfeed valve moves to the end of its travel
- make sure that the see/feel indicator operates smoothly, from the valve open (valve closed) position to the valve closed (valve open) position.
| ACTION | RESULT |
|---|---|
| 1.Open tag and safety C/B 1QE. | |
2.On the fuel control panel 40VU:
| On the panel 40VU:
|
3.On the fuel control panel 40VU:
| On the panel 40VU:
|
| 4.Remove the safety clip(s) and the tag(s) and close C/B 1QE. | |
| 5.Open, safety and tag C/B 2QE. | |
6.On the fuel control panel 40VU:
| On the panel 40VU:
NOTE: The X FEED P/BSW OPEN light will not come on when cicuit breaker 2QE is open. On the valve actuator, when the valve is fully open:
|
7.On the fuel control panel 40VU:
| On the panel 40VU:
|
| 8.Remove the safety clip(s) and the tag(s) and close C/B 2QE. | |
Subtask 28-40-00-410-052-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the RH MLG door (Ref. AMM TASK 32-12-00-410-001).
(3) Close the access door 192MB.
Subtask 28-40-00-410-052-C ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the RH MLG door (Ref. AMM TASK 32-12-00-410-001).
(3) Close the access door 192MB.
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the RH MLG door (Ref. AMM TASK 32-12-00-410-001).
(3) Close the access door 622KB.
Subtask 28-40-00-862-051-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the RH MLG door (Ref. AMM TASK 32-12-00-410-001).
(3) Close the access door 622KB.
B. De-energize the Electrical Circuits
(1) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
Subtask 28-40-00-942-055-A (1) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
C. Removal of Equipment
(1) Make a note in the aircraft technical log to say that the crossfeed valve indication (on the ECAM lower DU) is deactivated.
(2) Remove the safety barriers.
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make a note in the aircraft technical log to say that the crossfeed valve indication (on the ECAM lower DU) is deactivated.
(2) Remove the safety barriers.
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Fuel Crossfeed Valve