W DOC AIRBUS | AMM A320F

APU LP VALVE - Reactivation


TASK 28-29-00-440-002-A
APU LP VALVE - Reactivation


FIN: 14QM
1. Reason for the Job
MMEL 28-29-01B
APU LP FUEL VALVE
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
STEPLADDER 2.0 M (6.6 FT)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 28-29-51-400-001-A
Installation of the APU Fuel LP Valve Actuator
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
TSM 28-29-00-810-801
APU Fuel Supply Failure
3. Job Set-up
Subtask 28-29-00-860-056-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
Subtask 28-29-00-865-060-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAPU/FUEL/LP VALVE/CTL1QFM40
121VUAPU/FUEL/LP VALVE/SPLY2QFM39
Subtask 28-29-00-010-052-A
C. Get Access
   (1) Open the main landing-gear doors Z734, Z744 (Ref. AMM TASK 32-12-00-010-001).
   (2) Put the STEPLADDER 2.0 M (6.6 FT) in position at the main landing-gear bay.
4. Procedure
Subtask 28-29-00-440-050-A
A. Reactivation of the APU LP Shutoff Valve (Actuator P/N B27000)
   (1) If the LP-valve actuator was removed to deactivate the LP shutoff valve do the following steps:
     (a) Remove the electrical connectors (2) from the locking device (8).
     (b) Remove the nuts (3), the washers (4) and the bonding strap (5) from the actuator mount studs (9).
     (c) Remove the locking device (8).
     (d) Install the APU-fuel LP-valve actuator (1) (Ref. AMM TASK 28-29-51-400-001).
   (2) If the LP shutoff valve was deactivated without a removal of the actuator do following steps:
     (a) Remove the tie-wraps from the tied back cables/connectors (2).
     (b) Make sure that all the electrical connections are clean and in the correct condition.
     (c) Connect the connectors (2) to the actuator.
Subtask 28-29-00-440-051-A
B. Reactivation of the APU LP Shutoff Valve (Actuator P/N A08000)
   (1) If the LP-valve actuator was removed to deactivate the LP shutoff valve do the following steps:
     (a) Remove the tie-wraps (8) from the tied back cables/connectors (4).
     (b) Make sure that all the electrical connections are clean and in the correct condition.
     (c) Remove the screw (3) and the bonding strap (2) from the locking cover (5).
     (d) Remove the V-Band clamp (6) and the locking cover (5).
     (e) Install the APU-fuel LP-valve actuator (1) (Ref. AMM TASK 28-29-51-400-001).
   (2) If the LP shutoff valve was deactivated without a removal of the actuator do following steps:
     (a) Remove the tie-wraps (8) from the tied back cables/connectors (4).
     (b) Make sure that all the electrical connections are clean and in the correct condition.
     (c) Connect the connectors (4) to the actuator.
Subtask 28-29-00-865-059-A
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAPU/FUEL/LP VALVE/CTL1QFM40
121VUAPU/FUEL/LP VALVE/SPLY2QFM39
Subtask 28-29-00-810-050-A
D. Trouble Shooting
   (1) Trouble shoot the APU LP Fuel Shutoff-Valve TSM 28-29-00-810-801.
   (2) Remove the WARNING NOTICE(S).
   (3) Make an entry in the logbook that the APU LP Fuel Shutoff-Valve is reactivated.
5. Close-up
Subtask 28-29-00-410-053-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the stepladder.
   (3) Close the main landing-gear doors Z734, Z744 (Ref. AMM TASK 32-12-00-410-001).
Subtask 28-29-00-860-057-A
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:18:02 UTC