W DOC AIRBUS | AMM A320F

Removal of the ACT Vent-Valve Actuator


TASK 28-28-72-000-001-A
Removal of the ACT Vent-Valve Actuator


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: OBEY THE FUEL SAFETY PROCEDURES.
ZONE: 140
FIN: 91QH ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CAP - BLANKING
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
140
CENTER WING
195BB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 28-00-00-910-001-A
Fuel Safety Procedures
3. Job Set-up
Subtask 28-28-72-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) On the APU section of overhead panel 25VU, make sure that the APU/MASTER SW pushbutton switch is released (the ON legend is off).
   (3) On the FUEL section of HYD/FUEL panel 40VU, make sure that all the L TK PUMPS and R TK PUMPS pushbutton switches are released (the OFF legends are on).
   (4) Put the WARNING NOTICE(S) in position:
  • On the APU section of overhead panel 25VU to tell persons not to operate the APU/MASTER SW pushbutton switch
  • On the FUEL section of panel 40VU to tell persons not to operate the fuel system
  • On the ENG/APU FIRE panel on overhead panel 20VU to tell persons not to operate the fire extinguishing system.
  • On the Additional Center Tank (ACT) section of control panel 28VU to tell persons not to operate the fuel system.
   (5) You must obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001) when you do work on the fuel system.
   (6) Put the WARNING NOTICE(S) in position to tell persons not to operate the main gear doors.
Subtask 28-28-72-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open access panel 195BB.
   (2) Put an ACCESS PLATFORM 2M (6 FT) in position at zone 195.
4. Procedure
Subtask 28-28-72-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Actuator
F ACT Vent-Valve Actuator ** ON A/C NOT FOR ALL
   (1) Disconnect the electrical connectors (6) from the actuator (5).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove the four nuts (2).
   (4) Remove the actuator (5) and the mounting flange assembly (1).
   (5) Remove the mounting flange (1) from the actuator (5) as follows:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Cut and discard the lockwire from the screw (7).
     (b) Loosen the screw (7) and remove the V-clamp (3).
     (c) Remove and discard the O-ring (4) from the mounting flange (1).
     (d) Put the PLUG-BLANKING in each disconnected line end.
[Rev.10 from 2021] 2026.04.02 07:03:33 UTC