W DOC AIRBUS | AMM A320F

Removal of the ACT Vent Valve


TASK 28-28-62-000-001-A
Removal of the ACT Vent Valve


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: OBEY THE FUEL SAFETY PROCEDURES.
ZONE: 152
FIN: 234QM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CONTAINER 5 L (1.32 USGAL)
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
152
AFT CARGO COMPARTMENT
148AZ
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 28-00-00-910-001-A
Fuel Safety Procedures
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 28-25-00-650-001-A
Pressure Defuel
TASK 28-28-72-000-001-A
Removal of the ACT Vent-Valve Actuator
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 57-17-11-000-001-B
Removal of Access Cover 148AZ or/and the ACT-Equipment Support Door
3. Job Set-up
Subtask 28-28-62-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) On the APU section of overhead panel 25VU, make sure that the APU/MASTER SW pushbutton switch is released (the ON legend is off).
   (3) On the FUEL section of HYD/FUEL panel 40VU, make sure that all the L TK PUMPS and R TK PUMPS pushbutton switches are released (the OFF legends are on).
   (4) Put the WARNING NOTICE(S) in position:
  • On the APU section of overhead panel 25VU to tell persons not to operate the APU/MASTER SW pushbutton switch
  • On the FUEL section of panel 40VU to tell persons not to operate the fuel system
  • On the ENG/APU FIRE panel on overhead panel 20VU to tell persons not to operate the fire extinguishing system
  • On the Additional Center Tank (ACT) section of control panel 28VU to tell persons not to operate the fuel system.
   (5) You must obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001) when you do work on the fuel system.
   (6) Put the WARNING NOTICE(S) in position to tell persons not to operate the main gear doors.
Subtask 28-28-62-650-050-A ** ON A/C NOT FOR ALL
B. Defuel the center tank (Ref. AMM TASK 28-25-00-650-001).
Subtask 28-28-62-865-054-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUFUEL/ACT VENT VLV/MAN/SPLY62QHL21
121VUFUEL/ACT VENT VLV/AUTO/SPLY61QHL20
Subtask 28-28-62-010-050-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Open the right Main Landing Gear (MLG) door (Ref. AMM TASK 32-12-00-010-001).
   (2) Put the ACCESS PLATFORM 2M (6 FT) in position at the right MLG door.
Subtask 28-28-62-020-050-A ** ON A/C NOT FOR ALL
E. Preparation for Removal
   (1) Remove the ACT vent-valve actuator (Ref. AMM TASK 28-28-72-000-001).
Subtask 28-28-62-010-051-A ** ON A/C NOT FOR ALL
F. Get Access
   (1) Get access to the fuel center tank (Ref. AMM TASK 28-10-00-910-002).
4. Procedure
Subtask 28-28-62-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Vent Valve
F ACT Vent Valve ** ON A/C NOT FOR ALL
   (1) Put a CONTAINER 5 L (1.32 USGAL) below the connections between the vent valve (5) and the flanges (7) and (2).
   (2) Remove the nut (23) and the screw (21) and disconnect the bonding strap (22) from the vent valve (5).
   (3) Remove the nut (6) and the screw (9) and disconnect the bonding straps (10), (11) and (12) from the flange (7).
   (4) Remove the nut (17) and the screw (19) and disconnect the bonding straps (12) and (18) from the vent valve (5).
   (5) Remove the nut (3) and the screw (1) and disconnect the bonding strap (18) from the flange (2).
   (6) Remove the nuts (13) and the screws (8) and disconnect the flange (7) from the vent valve (5).
   (7) Remove the nuts (14) and the screws (20) and disconnect the flange (2) from the vent valve (5).
   (8) Remove and discard the O-rings (4).
   (9) Remove the nuts (16) from the studs (15).
   (10) Remove the vent valve (5).
NOTE: The play at the connection between the flanges (7) and (2) will help you remove the vent valve (5).
   (11) Put the PLUG-BLANKING in each disconnected line end.
[Rev.10 from 2021] 2026.04.02 06:18:01 UTC