W DOC AIRBUS | AMM A320F

Removal of the ACT Air Shut-Off Valve Actuator


TASK 28-28-56-000-001-A
Removal of the ACT Air Shut-Off Valve Actuator


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
FIN: 3QH ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
151BC
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 25-55-11-000-002-A
Removal of the Ceiling Panels in the Aft Cargo-Compartment - FR47/FR59
TASK 28-00-00-910-001-A
Fuel Safety Procedures
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 28-28-56-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
   (2) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
   (3) Put a WARNING NOTICE(S) in position:
  • the refuel/defuel panel 801VU,
  • the fuel panel 40VU,
    to tell persons not to operate the refuel/defuel system.
Subtask 28-28-56-010-051-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
   (2) Put an ACCESS PLATFORM 2M (6 FT) in position at the opening of the aft cargo-compartment.
   (3) In the aft cargo-compartment, remove the cargo-ceiling panel 151BC (Ref. AMM TASK 25-55-11-000-002).
Subtask 28-28-56-865-050-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUACT1/REFUEL & SPLY33QUL29
121VUFUEL/HI/LVL/SPLY1QJL25
121VUFUEL/RFL/DFL/SPLY2QUL24
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL23
121VUACT XFR VALVE MAN CTL30QHN29
121VUACT1/CTL & SPLY9QHP29
121VUACT PUMP SUPPLY25QHQ29
4. Procedure
Subtask 28-28-56-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Actuator of the ACT Air Shut-Off Valve
   (1) Disconnect the electrical connector (1) from the receptacle (7).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Loosen the screw (6), then open and remove the V-clamp (3) from the actuator (2).
   (4) Remove the actuator (2) from the air shut-off valve (4).
   (5) Remove and discard the O-ring (5).
[Rev.10 from 2021] 2026.04.02 07:03:42 UTC