W DOC AIRBUS | AMM A320F

Removal of the ACT Transfer-Valve Actuator


TASK 28-28-53-000-001-A
Removal of the ACT Transfer-Valve Actuator


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: OBEY THE FUEL SAFETY PROCEDURES.
ZONE: 147
ZONE: 150
FIN: 6QH ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CAP - BLANKING
No specific
AR
CONTAINER 1 L (1/4 USGAL)
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
147
MAIN GEAR WELL AND HYDRAULIC COMPARTMENT
150
AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 28-00-00-910-001-A
Fuel Safety Procedures
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 57-17-11-000-003-A
Removal of the Protective Cover of the ACT-Equipment Support Door
3. Job Set-up
Subtask 28-28-53-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) On the APU section of overhead panel 25VU, make sure that the APU/MASTER SW pushbutton switch is released (the ON legend is off).
   (3) On the FUEL section of HYD/FUEL panel 40VU, make sure that all the L TK PUMPS and R TK PUMPS pushbutton switches are released (the OFF legends are on).
   (4) Put the WARNING NOTICE(S) in position:
  • On the APU section of overhead panel 25VU to tell persons not to operate the APU/MASTER SW pushbutton switch
  • On the FUEL section of panel 40VU to tell persons not to operate the fuel system
  • On the ENG/APU FIRE panel on overhead panel 20VU to tell persons not to operate the fire extinguishing system
  • On the Additional Center Tank (ACT) section of control panel 28VU to tell persons not to operate the fuel system.
   (5) You must obey the fuel safety procedures when you do work on the fuel system (Ref. AMM TASK 28-00-00-910-001).
   (6) Put a WARNING NOTICE(S) in position to tell persons not to operate the Main Landing Gear (MLG) doors.
Subtask 28-28-53-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUFUEL/RFL/DFL/SPLY2QUL24
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL23
** ON A/C NOT FOR ALL
121VUFUEL/RFL/DFL/SPLY2QUL23
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL22
Subtask 28-28-53-010-050-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the left MLG door (Ref. AMM TASK 32-12-00-010-001).
   (2) Put the ACCESS PLATFORM 2M (6 FT) in position at the left MLG door.
   (3) Remove the protective cover of the ACT-Equipment Support Door (Ref. AMM TASK 57-17-11-000-003).
4. Procedure
Subtask 28-28-53-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the ACT Transfer-Valve Actuator
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
   (1) Disconnect the electrical connectors (11) from the ACT transfer-valve actuator (1).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Put a CONTAINER 1 L (1/4 USGAL) below the ACT transfer-valve actuator (1).
   (4) Loosen and remove the nut (8), the washer (9) and the screw (5).
   (5) Remove the bonding strap (4) from the mounting flange (7).
   (6) Remove the four nuts (6).
   (7) Remove the ACT transfer-valve actuator (1) and the mounting flange assembly.
   (8) Remove the ACT transfer-valve actuator (1) from the mounting flange (7) as follows:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Remove and discard the lockwire from the screw (10).
     (b) Loosen the screw (10) and remove the V-clamp (3).
     (c) Remove and discard the O-ring (2) from the mounting flange (7).
     (d) Put the PLUG-BLANKING in each disconnected line end.
[Rev.10 from 2021] 2026.04.02 07:03:30 UTC