Installation of the ACT Refuel Restrictor-Valve(s)
TASK 28-28-45-400-003-A
Installation of the ACT Refuel Restrictor-Valve(s)
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 28-28-45-860-057-C ** ON A/C NOT FOR ALL
Subtask 28-28-45-420-052-A ** ON A/C NOT FOR ALL
Subtask 28-28-45-860-058-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:59 UTC
Installation of the ACT Refuel Restrictor-Valve(s)
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
WARNING:
BE CAREFUL NOT TO GET AIRCRAFT FUEL IN YOUR MOUTH OR IN YOUR EYES.
IF YOU GET FUEL ON YOUR SKIN OR ON YOUR CLOTHES, FLUSH IT IMMEDIATELY WITH WATER.
IF NECESSARY, GET MEDICAL HELP.
AIRCRAFT FUEL IS POISONOUS.
WARNING:
DO NOT GET YOUR CLOTHES SOAKED WITH FUEL.
WARNING:
MAKE SURE THAT YOU HAVE THE CORRECT FIRE FIGHTING EQUIPMENT AVAILABLE.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| 160 | BULK CARGO COMPARTMENT AFT BULKHEAD OF AFT CARGO COMPARTMENT TO AFT BULKHEAD OF BULK CARGO COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-25-00-650-005-A | To Drain the Remaining Fuel from the Additional Center Tank (ACT) |
| TASK 28-25-00-710-003-A | Operational Test of the Refuel System |
| FOR [230QM1] (VALVE-REFUEL RESTRICTOR, ACT1) | |
| TASK 28-11-27-000-002-A | Removal of Additional Center Tank No.1 (ACT AFT1) |
| TASK 28-11-27-400-002-A | Installation of Additional Center Tank No.1 (ACT AFT1) |
| FOR [230QM2] (VALVE-REFUEL RESTRICTOR, ACT2) | |
| TASK 28-11-27-000-003-A | Removal of the Additional Center Tank No.2 (ACT AFT2) |
| TASK 28-11-27-400-003-A | Installation of the Additional Center Tank No.2 (ACT AFT2) |
Subtask 28-28-45-860-057-C ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Obey the safety procedures when you work in a fuel tank (Ref. AMM TASK 28-10-00-910-001).
(3) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(4) Make sure that the ACTs are completely drained from fuel (Ref. AMM TASK 28-25-00-650-005).
(5) FOR [230QM2] (VALVE-REFUEL RESTRICTOR, ACT2)
(a) Make sure that the ACT AFT2 is removed (Ref. AMM TASK 28-11-27-000-003).
(6) FOR [230QM1] (VALVE-REFUEL RESTRICTOR, ACT1)
(a) Make sure that the ACT AFT1 is removed (Ref. AMM TASK 28-11-27-000-002).
(7) On refuel/defuel control panels 801VU and 800VU and on fuel control panel 40VU:
(a) Make sure that the warning notices are in position to tell persons not to operate the refuel/defuel system.
4. Procedure(1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Obey the safety procedures when you work in a fuel tank (Ref. AMM TASK 28-10-00-910-001).
(3) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(4) Make sure that the ACTs are completely drained from fuel (Ref. AMM TASK 28-25-00-650-005).
(5) FOR [230QM2] (VALVE-REFUEL RESTRICTOR, ACT2)
(a) Make sure that the ACT AFT2 is removed (Ref. AMM TASK 28-11-27-000-003).
(6) FOR [230QM1] (VALVE-REFUEL RESTRICTOR, ACT1)
(a) Make sure that the ACT AFT1 is removed (Ref. AMM TASK 28-11-27-000-002).
(7) On refuel/defuel control panels 801VU and 800VU and on fuel control panel 40VU:
(a) Make sure that the warning notices are in position to tell persons not to operate the refuel/defuel system.
Subtask 28-28-45-420-052-A ** ON A/C NOT FOR ALL
A. Installation of the Refuel Restrictor Valve
Subtask 28-28-45-410-054-C ** ON A/C NOT FOR ALL CAUTION:
DO THIS PROCEDURE ONLY IN THE WORKSHOP. IF YOU DO NOT OBEY THIS INSTRUCTION, DAMAGE TO THE BLADDER TANK CAN OCCUR.
(1) Install the ACT refuel restrictor-valve(s) in the workshop.B. Close Access
(1) FOR [230QM1] (VALVE-REFUEL RESTRICTOR, ACT1)
(a) Install the ACT AFT1 (Ref. AMM TASK 28-11-27-400-002).
(2) FOR [230QM2] (VALVE-REFUEL RESTRICTOR, ACT2)
(a) Install the ACT AFT2 (Ref. AMM TASK 28-11-27-400-003).
Subtask 28-28-45-710-052-A ** ON A/C NOT FOR ALL 5. Close-up(1) FOR [230QM1] (VALVE-REFUEL RESTRICTOR, ACT1)
(a) Install the ACT AFT1 (Ref. AMM TASK 28-11-27-400-002).
(2) FOR [230QM2] (VALVE-REFUEL RESTRICTOR, ACT2)
(a) Install the ACT AFT2 (Ref. AMM TASK 28-11-27-400-003).
Subtask 28-28-45-860-058-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to the serviceable condition.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) From refuel/defuel control panels 801VU and 800VU and from fuel control panel 40VU:
(a) Remove the WARNING NOTICE(S).
(3) De-energize the ground service network (Ref. AMM TASK 24-42-00-862-001).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) From refuel/defuel control panels 801VU and 800VU and from fuel control panel 40VU:
(a) Remove the WARNING NOTICE(S).
(3) De-energize the ground service network (Ref. AMM TASK 24-42-00-862-001).