Installation of the ACT Cabin Air Intake Check Valve
TASK 28-28-43-400-001-A
Installation of the ACT Cabin Air Intake Check Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-28-43-860-051-A ** ON A/C NOT FOR ALL
Subtask 28-28-43-420-050-A ** ON A/C NOT FOR ALL
Subtask 28-28-43-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:58 UTC
Installation of the ACT Cabin Air Intake Check Valve
WARNING:
BE CAREFUL NOT TO GET AIRCRAFT FUEL IN YOUR MOUTH OR IN YOUR EYES.
IF YOU GET FUEL ON YOUR SKIN OR ON YOUR CLOTHES, FLUSH IT IMMEDIATELY WITH WATER.
IF NECESSARY, GET MEDICAL HELP.
AIRCRAFT FUEL IS POISONOUS.
WARNING:
DO NOT GET YOUR CLOTHES SOAKED WITH FUEL.
WARNING:
MAKE SURE THAT YOU HAVE THE CORRECT FIRE FIGHTING EQUIPMENT AVAILABLE.
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
FIN: 179QM ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 151BC |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-55-11-000-002-A | Removal of the Ceiling Panels in the Aft Cargo-Compartment - FR47/FR59 |
| TASK 25-55-11-400-002-A | Installation of the Ceiling Panels in the Aft Cargo-Compartment - FR47/FR59 |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 28-28-00-710-004-A | Operational Test of the ACT Automatic Transfer System |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 28-28-43-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Obey the fuel safety procedure (Ref. AMM TASK 28-00-00-910-001).
(2) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(3) Make sure that a WARNING NOTICE(S) is in position on:
Subtask 28-28-43-010-052-A ** ON A/C NOT FOR ALL (1) Obey the fuel safety procedure (Ref. AMM TASK 28-00-00-910-001).
(2) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(3) Make sure that a WARNING NOTICE(S) is in position on:
- the refuel/defuel panel 801VU,
- the fuel panel 40VU,
to tell persons not to operate the refuel/defuel system.
B. Get Access
(1) Make sure that the aft cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-001).
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the opening of the aft cargo-compartment.
(3) In the aft cargo-compartment, make sure that the ceiling panel 151BC is removed (Ref. AMM TASK 25-55-11-000-002).
Subtask 28-28-43-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the aft cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-001).
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the opening of the aft cargo-compartment.
(3) In the aft cargo-compartment, make sure that the ceiling panel 151BC is removed (Ref. AMM TASK 25-55-11-000-002).
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ACT1/REFUEL & SPLY | 33QU | L29 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L25 |
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| 121VU | ACT XFR VALVE MAN CTL | 30QH | N29 |
| 121VU | ACT1/CTL & SPLY | 9QH | P29 |
| 121VU | ACT PUMP SUPPLY | 25QH | Q29 |
Subtask 28-28-43-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Check Valve
(1) Remove the PLUG-BLANKING from each disconnected line end.
(2) Clean the component interfaces and the adjacent area.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Put the check valve (4) in position.
(5) Install the union nut (3) on the check valve (4).
(6) Install the union nut (5) of the T-pipe section (6) on the check valve (4).
(7) If removed, install the test coupling (1) to the T-pipe section (6).
Subtask 28-28-43-865-052-A ** ON A/C NOT FOR ALL (1) Remove the PLUG-BLANKING from each disconnected line end.
(2) Clean the component interfaces and the adjacent area.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Put the check valve (4) in position.
(5) Install the union nut (3) on the check valve (4).
(6) Install the union nut (5) of the T-pipe section (6) on the check valve (4).
(7) If removed, install the test coupling (1) to the T-pipe section (6).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 28-28-43-710-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ACT1/REFUEL & SPLY | 33QU | L29 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L25 |
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| 121VU | ACT XFR VALVE MAN CTL | 30QH | N29 |
| 121VU | ACT1/CTL & SPLY | 9QH | P29 |
| 121VU | ACT PUMP SUPPLY | 25QH | Q29 |
C. Test
(1) Do the Operational Test of the ACT Automatic Transfer System (Ref. AMM TASK 28-28-00-710-004).
5. Close-up(1) Do the Operational Test of the ACT Automatic Transfer System (Ref. AMM TASK 28-28-00-710-004).
Subtask 28-28-43-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) In the aft cargo-compartment, install the ceiling panel 151BC (Ref. AMM TASK 25-55-11-400-002).
(2) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
Subtask 28-28-43-860-052-A ** ON A/C NOT FOR ALL (1) In the aft cargo-compartment, install the ceiling panel 151BC (Ref. AMM TASK 25-55-11-400-002).
(2) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
B. Put the aircraft back to the serviceable condition.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(4) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(4) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).