Installation of the Cabin Air Intake Filter-Assembly
TASK 28-28-39-400-001-A
Installation of the Cabin Air Intake Filter-Assembly
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-28-39-860-051-A ** ON A/C NOT FOR ALL
Subtask 28-28-39-420-050-A ** ON A/C NOT FOR ALL
Subtask 28-28-39-410-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:57 UTC
Installation of the Cabin Air Intake Filter-Assembly
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
FIN: 183QM ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 152DW |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-55-11-000-003-A | Removal of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59 |
| TASK 25-55-11-400-003-A | Installation of the Sidewall Panels in the Aft Cargo Compartment - FR47/FR59 |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 28-28-39-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(3) Make sure that a WARNING NOTICE(S) is in position:
Subtask 28-28-39-010-058-A ** ON A/C NOT FOR ALL (1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
(3) Make sure that a WARNING NOTICE(S) is in position:
- the refuel/defuel control panel 800/801VU,
- the fuel control panel 40VU,
to tell persons not to operate the refuel/defuel system.
B. Get Access
(1) Make sure that the aft cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-001).
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the opening of the aft cargo-compartment.
(3) In the aft cargo-compartment, make sure that the sidewall panel 152DW is removed (Ref. AMM TASK 25-55-11-000-003).
Subtask 28-28-39-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the aft cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-001).
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the opening of the aft cargo-compartment.
(3) In the aft cargo-compartment, make sure that the sidewall panel 152DW is removed (Ref. AMM TASK 25-55-11-000-003).
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ACT1/REFUEL & SPLY | 33QU | L29 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L25 |
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| 121VU | ACT XFR VALVE MAN CTL | 30QH | N29 |
| 121VU | ACT1/CTL & SPLY | 9QH | P29 |
| 121VU | ACT PUMP SUPPLY | 25QH | Q29 |
Subtask 28-28-39-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Air Filter Assembly
(1) Remove the PLUG-BLANKING from each disconnected line end.
(2) Clean the component interfaces and the adjacent area.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Put the air filter assembly (1) in position.
(5) Connect the pipe (3) to the air filter assembly (1).
(6) Install the self-locking nuts (4) and the washers (5) on the air filter assembly (1).
(7) Tighten the union nut (2).
5. Close-up(1) Remove the PLUG-BLANKING from each disconnected line end.
(2) Clean the component interfaces and the adjacent area.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Put the air filter assembly (1) in position.
(5) Connect the pipe (3) to the air filter assembly (1).
(6) Install the self-locking nuts (4) and the washers (5) on the air filter assembly (1).
(7) Tighten the union nut (2).
Subtask 28-28-39-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
(1) In the aft cargo-compartment, install the sidewall panel 152DW (Ref. AMM TASK 25-55-11-400-003).
(2) Remove the access platform(s).
(3) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
Subtask 28-28-39-865-052-A ** ON A/C NOT FOR ALL (1) In the aft cargo-compartment, install the sidewall panel 152DW (Ref. AMM TASK 25-55-11-400-003).
(2) Remove the access platform(s).
(3) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 28-28-39-860-061-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ACT1/REFUEL & SPLY | 33QU | L29 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L25 |
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| 121VU | ACT XFR VALVE MAN CTL | 30QH | N29 |
| 121VU | ACT1/CTL & SPLY | 9QH | P29 |
| 121VU | ACT PUMP SUPPLY | 25QH | Q29 |
C. Put the aircraft back to the serviceable condition.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
(3) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the WARNING NOTICE(S).
(3) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
Cabin Air Intake Filter-Assembly