W DOC AIRBUS | AMM A320F

Installation of the ACT Air Shut-Off Valve


TASK 28-28-36-400-001-A
Installation of the ACT Air Shut-Off Valve


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
WARNING: BE CAREFUL NOT TO GET AIRCRAFT FUEL IN YOUR MOUTH OR IN YOUR EYES. IF YOU GET FUEL ON YOUR SKIN OR ON YOUR CLOTHES, FLUSH IT IMMEDIATELY WITH WATER. IF NECESSARY, GET MEDICAL HELP. AIRCRAFT FUEL IS POISONOUS.
WARNING: DO NOT GET YOUR CLOTHES SOAKED WITH FUEL.
WARNING: MAKE SURE THAT YOU HAVE THE CORRECT FIRE FIGHTING EQUIPMENT AVAILABLE.
FIN: 168QM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 28-00-00-910-001-A
Fuel Safety Procedures
TASK 28-28-56-000-001-A
Removal of the ACT Air Shut-Off Valve Actuator
TASK 28-28-56-400-001-A
Installation of the ACT Air Shut-Off Valve Actuator
3. Job Set-up
Subtask 28-28-36-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
   (2) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
   (3) Make sure that a WARNING NOTICE(S) is in position on:
  • the refuel/defuel panel 801VU,
  • the fuel panel 40VU,
    to tell persons not to operate the refuel/defuel system.
Subtask 28-28-36-010-053-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Make sure that the Actuator of the Air Shut-Off Valve is removed (Ref. AMM TASK 28-28-56-000-001).
Subtask 28-28-36-865-051-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUACT1/REFUEL & SPLY33QUL29
121VUFUEL/HI/LVL/SPLY1QJL25
121VUFUEL/RFL/DFL/SPLY2QUL24
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL23
121VUACT XFR VALVE MAN CTL30QHN29
121VUACT1/CTL & SPLY9QHP29
121VUACT PUMP SUPPLY25QHQ29
4. Procedure
Subtask 28-28-36-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Air Shut-Off Valve
   (1) Remove the PLUG-BLANKING from each disconnected line end.
   (2) Clean the component interfaces and the adjacent area.
   (3) Do an inspection of the component interfaces and the adjacent area.
   (4) Put the air shut-off valve (1) in position so that the studs (4) go through the attachment bracket (8).
   (5) Install the nuts (6) and washers (7) on the studs (4).
   (6) Install the union nut (3) on the port (2) of the air shut-off valve (1).
   (7) Install the union nut (5) on the port (9) of the air shut-off valve (1).
NOTE: The test of the valve is given after the installation of the actuator of the air shut-off valve.
5. Close-up
Subtask 28-28-36-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install the Actuator of the Air Shut-Off Valve (Ref. AMM TASK 28-28-56-400-001).
Subtask 28-28-36-865-052-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUACT1/REFUEL & SPLY33QUL29
121VUFUEL/HI/LVL/SPLY1QJL25
121VUFUEL/RFL/DFL/SPLY2QUL24
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL23
121VUACT XFR VALVE MAN CTL30QHN29
121VUACT1/CTL & SPLY9QHP29
121VUACT PUMP SUPPLY25QHQ29
Subtask 28-28-36-860-052-A ** ON A/C NOT FOR ALL
C. Put the aircraft back to the serviceable condition.
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
   (4) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.02 06:17:56 UTC