Removal of the ACT Air Shutoff Valve


TASK 28-28-36-000-002-A
Removal of the ACT Air Shutoff Valve


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
ZONE: 150
FIN: 233QM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
150
AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT
151BC, 826
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 25-55-11-000-002-A
Removal of the Ceiling Panels in the Aft Cargo-Compartment - FR47/FR59
TASK 28-00-00-910-001-A
Fuel Safety Procedures
TASK 28-28-56-000-002-A
Removal of the ACT Air Shutoff Valve Actuator
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
3. Job Set-up
Subtask 28-28-36-860-053-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
   (2) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (3) On refuel/defuel control panels 800VU and 801VU, on fuel control panel 40VU and on Additional Center Tank (ACT) control panel 28VU:
     (a) Put the WARNING NOTICE(S) in position to tell persons not to operate the refuel/defuel system.
Subtask 28-28-36-865-053-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUFUEL/ACT AIR SOV/MAN/SPLY64QHJ20
121VUFUEL/ACT AIR SOV/AUTO/SPLY63QHJ19
121VUFUEL/ACT XFR VLV/MOT266QHJ18
121VUFUEL/ACT XFR VLV/MOT165QHJ17
121VUFUEL/HI/LVL/SPLY1QJL24
121VUFUEL/RFL/DFL/SPLY2QUL23
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL22
121VUFUEL/ACT VENT VLV/MAN/SPLY62QHL21
121VUFUEL/ACT VENT VLV/AUTO/SPLY61QHL20
121VUFUEL/ACT/FUEL PUMP/SPLY25QHQ29
Subtask 28-28-36-010-052-B ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) in position at aft cargo-compartment door 826.
   (2) Open aft cargo-compartment door 826 (Ref. AMM TASK 52-30-00-860-001).
   (3) Set CARGO COMPT LIGHT switch 8LU to the ON position.
   (4) In the aft cargo-compartment, remove cargo ceiling panel 151BC (Ref. AMM TASK 25-55-11-000-002).
   (5) Remove the actuator of the air shutoff valve (Ref. AMM TASK 28-28-56-000-002).
4. Procedure
Subtask 28-28-36-020-051-B ** ON A/C NOT FOR ALL
A. Removal of the Air Shutoff Valve
CAUTION: USE A SECOND WRENCH TO HOLD THE FITTINGS WHEN YOU LOOSEN/TIGHTEN THE TUBE COUPLING NUTS. THIS PREVENTS DAMAGE TO THE TUBES.
   (1) Loosen the nuts (3) and (5) and disconnect the tubes (2) and (9).
   (2) Put the PLUG-BLANKING in each disconnected line end.
   (3) Remove the nuts (6) and the washers (7) from the bolts (4).
   (4) Remove the air shutoff valve (1) from the bracket (8).