W DOC AIRBUS | AMM A320F

Removal of the ACT Air Shut-Off Valve


TASK 28-28-36-000-001-A
Removal of the ACT Air Shut-Off Valve


WARNING: BE CAREFUL NOT TO GET AIRCRAFT FUEL IN YOUR MOUTH OR IN YOUR EYES. IF YOU GET FUEL ON YOUR SKIN OR ON YOUR CLOTHES, FLUSH IT IMMEDIATELY WITH WATER. IF NECESSARY, GET MEDICAL HELP. AIRCRAFT FUEL IS POISONOUS.
WARNING: DO NOT GET YOUR CLOTHES SOAKED WITH FUEL.
WARNING: MAKE SURE THAT YOU HAVE THE CORRECT FIRE FIGHTING EQUIPMENT AVAILABLE.
WARNING: OBEY THE FUEL SAFETY PROCEDURES.
FIN: 168QM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 28-00-00-910-001-A
Fuel Safety Procedures
TASK 28-28-56-000-001-A
Removal of the ACT Air Shut-Off Valve Actuator
3. Job Set-up
Subtask 28-28-36-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
   (2) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
   (3) Put a WARNING NOTICE(S) in position:
  • the refuel/defuel panel 801VU,
  • the fuel panel 40VU,
    to tell persons not to operate the refuel/defuel system.
Subtask 28-28-36-010-051-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Remove the Actuator of the Air Shut-Off Valve (Ref. AMM TASK 28-28-56-000-001).
Subtask 28-28-36-865-050-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUACT1/REFUEL & SPLY33QUL29
121VUFUEL/HI/LVL/SPLY1QJL25
121VUFUEL/RFL/DFL/SPLY2QUL24
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL23
121VUACT XFR VALVE MAN CTL30QHN29
121VUACT1/CTL & SPLY9QHP29
121VUACT PUMP SUPPLY25QHQ29
4. Procedure
Subtask 28-28-36-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Air Shut-Off Valve
   (1) Loosen the union nuts (3) and (5) from the ports (2) and (9) of the air shut-off valve (1).
   (2) Remove the nuts (6) and the washers (7) from the studs (4).
   (3) Remove the air shut-off valve (1) from the attachment bracket (8).
   (4) Put the PLUG-BLANKING in each disconnected line end.