W DOC AIRBUS | AMM A320F

Removal of the ACT Fuel Transfer-Valve


TASK 28-28-33-000-001-A
Removal of the ACT Fuel Transfer-Valve


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: OBEY THE FUEL SAFETY PROCEDURES.
ZONE: 140
FIN: 165QM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CONTAINER 5 L (1.32 USGAL)
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
140
CENTER WING
148AZ
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 28-00-00-910-001-A
Fuel Safety Procedures
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 28-25-00-650-001-A
Pressure Defuel
TASK 28-28-53-000-001-A
Removal of the ACT Transfer-Valve Actuator
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 57-17-11-000-001-B
Removal of Access Cover 148AZ or/and the ACT-Equipment Support Door
F ACT Fuel Transfer-Valve ** ON A/C NOT FOR ALL
F ACT Fuel Transfer-Valve ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 28-28-33-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) On the APU section of overhead panel 25VU, make sure that the APU/MASTER SW pushbutton switch is released (the ON legend is off).
   (3) On the FUEL section of HYD/FUEL panel 40VU, make sure that all the L TK PUMPS and R TK PUMPS pushbutton switches are released (the OFF legends are on).
   (4) Put the WARNING NOTICE(S) in position:
  • On the APU section of overhead panel 25VU to tell persons not to operate the APU/MASTER SW pushbutton switch
  • On the FUEL section of panel 40VU to tell persons not to operate the fuel system
  • On the ENG/APU FIRE panel on overhead panel 20VU to tell persons not to operate the fire extinguishing system
  • On the Additional Center Tank (ACT) section of control panel 28VU to tell persons not to operate the fuel system.
   (5) You must obey the fuel safety procedures when you do work on the fuel system (Ref. AMM TASK 28-00-00-910-001).
   (6) Put a WARNING NOTICE(S) in position to tell persons not to operate the MLG doors.
Subtask 28-28-33-650-051-A ** ON A/C NOT FOR ALL
B. Defuel the center tank (Ref. AMM TASK 28-25-00-650-001).
Subtask 28-28-33-865-050-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUFUEL/RFL/DFL/SPLY2QUL24
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL23
** ON A/C NOT FOR ALL
121VUFUEL/RFL/DFL/SPLY2QUL23
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL22
Subtask 28-28-33-010-050-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Open the right MLG door (Ref. AMM TASK 32-12-00-010-001).
   (2) Put the ACCESS PLATFORM 2M (6 FT) in position at the right MLG door.
Subtask 28-28-33-020-051-A ** ON A/C NOT FOR ALL
E. Preparation for Removal
   (1) Remove the ACT transfer-valve actuator (Ref. AMM TASK 28-28-53-000-001).
Subtask 28-28-33-010-051-A ** ON A/C NOT FOR ALL
F. Get Access
   (1) Get access to the fuel center tank (Ref. AMM TASK 28-10-00-910-002).
4. Procedure
Subtask 28-28-33-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Transfer Valve
   (1) Put a CONTAINER 5 L (1.32 USGAL) below the valve (9) and the connections between the lines (1) and (4).
   (2) Remove the nuts (8), the washers (6) and the bolts (5) and disconnect the bonding straps (7).
   (3) Loosen the nuts (3).
   (4) Remove the screws (11).
   (5) Remove the valve (9) from the lines (1) and (4).
NOTE: Play at the connections between the lines (1) and (4) will help you release the valve (9).
   (6) Remove and discard the O-rings (10) and (12).
   (7) Remove and discard the packings (2).
   (8) Put the PLUG-BLANKING in each disconnected line end.
Subtask 28-28-33-020-050-B ** ON A/C NOT FOR ALL
A. Removal of the ACT Fuel Transfer-Valve
   (1) Put a CONTAINER 5 L (1.32 USGAL) below the ACT fuel transfer-valve (10) and the connections between the lines (1) and (5).
   (2) Remove the nuts (9), the washers (7) and the bolts (6) and disconnect the bonding straps (8).
   (3) Loosen the nuts (4).
   (4) Remove the ACT fuel transfer-valve (10) from the lines (1) and (5).
NOTE: The play at the connections between the lines (1) and (5) will help you to release the ACT fuel transfer-valve (10).
   (5) Remove and discard the retaining rings (2).
   (6) Remove and discard the O-rings (3).
   (7) Remove the screws (12).
   (8) Remove the ACT fuel transfer-valve (10) from the structure.
   (9) Remove and discard the O-ring (11).
   (10) Put the PLUG-BLANKING in each disconnected line end.
[Rev.10 from 2021] 2026.04.02 07:03:31 UTC