Operational Check of the ACT Manual Transfer System (AFT Cargo-Compartment)
TASK 28-28-00-710-008-A
Operational Check of the ACT Manual Transfer System (AFT Cargo-Compartment)
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 28-28-00-860-100-B ** ON A/C NOT FOR ALL
Subtask 28-28-00-710-061-B ** ON A/C NOT FOR ALL
Subtask 28-28-00-860-101-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:51 UTC
Operational Check of the ACT Manual Transfer System (AFT Cargo-Compartment)
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
1. Reason for the JobNOTE: This procedure is only applicable if the aircraft is equipped with Additional Center Tank (ACT) in the aft cargo-compartment.
2. Job Set-up InformationA. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 192MB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
Subtask 28-28-00-860-100-B ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(3) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(4) On the ECAM control panel push the FUEL pushbutton switch, on the lower ECAM DU the FUEL page comes into view.
(a) On the lower ECAM DU, make sure that the fuel quantity in ACT AFT1, ACT AFT2, and ACT FWD is 400 +50 kg or -150 kg (881.8488 +110.2311 lb or -330.6933 lb) in each ACT.
(b) On the lower ECAM DU, make sure that the fuel quantity in the RH and LH wing tanks is approximately 5000 +100 kg or -100 kg (11023.1100 +220.4622 lb or -220.4622 lb).
(c) On the lower ECAM DU, make sure that the fuel quantity in the center tank is approximately 250 kg (551.1555 lb).
(6) Open refuel/defuel control panel door 192MB.
Subtask 28-28-00-865-077-A ** ON A/C NOT FOR ALL (1) Obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
(2) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(3) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
(4) On the ECAM control panel push the FUEL pushbutton switch, on the lower ECAM DU the FUEL page comes into view.
(a) On the lower ECAM DU, make sure that the fuel quantity in ACT AFT1, ACT AFT2, and ACT FWD is 400 +50 kg or -150 kg (881.8488 +110.2311 lb or -330.6933 lb) in each ACT.
(b) On the lower ECAM DU, make sure that the fuel quantity in the RH and LH wing tanks is approximately 5000 +100 kg or -100 kg (11023.1100 +220.4622 lb or -220.4622 lb).
(c) On the lower ECAM DU, make sure that the fuel quantity in the center tank is approximately 250 kg (551.1555 lb).
NOTE: The 5000 kg fuel in the RH and LH wing tanks are used for ballast purposes. The weight of fuel in the wing tanks reduce the risk of a larger change on the longitudinal center of gravity, which can be caused by the higher load of fuel in the ACT(s), installed in the cargo compartment.
(5) Open the main gear doors for access (Ref. AMM TASK 32-12-00-010-001). (6) Open refuel/defuel control panel door 192MB.
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ALSCU SPLY | 66QJ | B10 |
| 121VU | FUEL/ACT XFR VLV/MOT2 | 66QH | J18 |
| 121VU | FUEL/ACT XFR VLV/MOT1 | 65QH | J17 |
| 121VU | FUEL/ALSCU/HI LEVEL/SPLY | 64QJ | K21 |
| 121VU | FUEL/ALSCU/SPLY | 65QJ | K20 |
| 121VU | FUEL/HI/LVL/SPLY | 1QJ | L24 |
| 121VU | FUEL/ACT/FUEL PUMP/SPLY | 25QH | Q29 |
Subtask 28-28-00-710-061-B ** ON A/C NOT FOR ALL
A. Operational Test of the ACT Fuel Manual Transfer
5. Close-up| ACTION | RESULT |
|---|---|
1.On overhead FUEL ACT panel 28VU:
| On the overhead FUEL ACT panel 28VU:
|
2.On overhead FUEL ACT panel 28VU:
| On the lower ECAM DU:
|
| | In the compartment of the main landing gear at FR 42 (Left port center tank access door):
|
3.On overhead FUEL ACT panel 28VU:
| On the lower ECAM DU:
|
| | In the compartment of the main landing gear at FR 42 (Left port center tank access door):
|
4.On overhead FUEL ACT panel 28VU:
| On the lower ECAM DU:
|
| | In the compartment of the main landing gear at FR 42 (Left port center tank access door):
|
5.On overhead FUEL ACT panel 28VU:
| On the overhead FUEL ACT panel 28VU:
|
| | On the lower ECAM DU:
|
| | In the compartment of the main landing gear at FR 42 (Left port center tank access door):
|
Subtask 28-28-00-860-101-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(4) Close refuel/defuel control panel door 192MB.
(5) Close the MLG doors (Ref. AMM TASK 32-12-00-410-001).
(6) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(4) Close refuel/defuel control panel door 192MB.
(5) Close the MLG doors (Ref. AMM TASK 32-12-00-410-001).
(6) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).