General Visual Inspection of the Forward ACT Isolation-Valve for the Closed Position
TASK 28-28-00-200-009-B
General Visual Inspection of the Forward ACT Isolation-Valve for the Closed Position
To make sure that the forward ACT isolation-valve is in the closed position when ACT FWD is removed from the forward cargo compartment and the aircraft must go for servicing without an ACT in the forward cargo compartment.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 28-28-00-860-239-A ** ON A/C NOT FOR ALL Subtask 28-28-00-010-123-A ** ON A/C NOT FOR ALL
Subtask 28-28-00-210-059-A ** ON A/C NOT FOR ALL
Subtask 28-28-00-410-084-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:55 UTC
General Visual Inspection of the Forward ACT Isolation-Valve for the Closed Position
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
FIN: 236QM ** ON A/C NOT FOR ALL
1. Reason for the JobTo make sure that the forward ACT isolation-valve is in the closed position when ACT FWD is removed from the forward cargo compartment and the aircraft must go for servicing without an ACT in the forward cargo compartment.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | LIGHT SOURCE - INSPECTION |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| ASM 284200 | |
Subtask 28-28-00-860-239-A ** ON A/C NOT FOR ALL Subtask 28-28-00-010-123-A ** ON A/C NOT FOR ALL
B. Get Access
(1) Open the left Main Landing Gear (MLG) door for access (Ref. AMM TASK 32-12-00-010-001).
(2) Put an ACCESS PLATFORM 1M(3 FT) in position at the left MLG bay.
(3) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(4) Put an ACCESS PLATFORM 2M (6 FT) in position at the forward cargo compartment.
4. Procedure(1) Open the left Main Landing Gear (MLG) door for access (Ref. AMM TASK 32-12-00-010-001).
(2) Put an ACCESS PLATFORM 1M(3 FT) in position at the left MLG bay.
(3) Open the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(4) Put an ACCESS PLATFORM 2M (6 FT) in position at the forward cargo compartment.
Subtask 28-28-00-210-059-A ** ON A/C NOT FOR ALL
A. General Visual Inspection of the Forward ACT Isolation-Valve for the Closed Position
(1) Use a LIGHT SOURCE - INSPECTION for this procedure.
(2) In the MLG bay, make sure that the position indicator of the forward ACT isolation-valve-actuator (92QH) is in the closed position:
5. Close-up(1) Use a LIGHT SOURCE - INSPECTION for this procedure.
(2) In the MLG bay, make sure that the position indicator of the forward ACT isolation-valve-actuator (92QH) is in the closed position:
- The forward ACT isolation-valve is closed when the position indicator of the actuator is in the vertical position.
- The forward ACT isolation-valve is open when the position indicator of the actuator is in the horizontal position.
| ACTION | RESULT |
|---|---|
1.In the cockpit on circuit breaker panels 49VU and 121VU:
| |
2.In the forward cargo compartment, on the ceiling:
| |
3.On connectors 3510VC and 3511VC:
NOTE: This is to simulate that ACT FWD is installed in the forward cargo compartment. | At the MLG bay, on the forward ACT isolation-valve-actuator (92QH):
|
4.In the cockpit on circuit breaker panels 49VU and 121VU:
| |
| 5.You must safetied these circuits breakers with the clamps and the lockwire before the aircraft goes for servicing without an ACT in the forward cargo compartment. | |
6.On the ceiling of the forward cargo compartment, at the electrical interfaces of ACT FWD, on connectors 3510VC and 3511VC:
| At the MLG bay, on the forward ACT isolation-valve-actuator (92QH):
|
Subtask 28-28-00-410-084-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the left MLG door (Ref. AMM TASK 32-12-00-410-001).
(4) Close the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
Subtask 28-28-00-860-240-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the left MLG door (Ref. AMM TASK 32-12-00-410-001).
(4) Close the forward cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
Position Indication of the Forward ACT Isolation-Valve