W DOC AIRBUS | AMM A320F

Deactivation of the ACT Transfer Valve in the Closed Position


TASK 28-28-00-040-015-A
Deactivation of the ACT Transfer Valve in the Closed Position


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
Task Summary
Access Test Specific Tools Mhr E/T Nb Men
NONOYES0.80.81
1. Reason for the Job
MMEL 28-46-02A
HIGH LEVEL DETECTION SYSTEM (FAA ONLY)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
TIE WRAP(S)
No specific
1
WARNING NOTICE(S)
T720456
1
TOOL - VALVE LOCKING
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 28-00-00-910-001-A
Fuel Safety Procedures
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
TASK 57-17-11-000-001-B
Removal of Access Cover 148AZ or/and the ACT-Equipment Support Door
TASK 57-17-11-000-003-A
Removal of the Protective Cover of the ACT-Equipment Support Door
TASK 57-17-11-400-001-B
Installation of Access Cover 148AZ or/and the ACT-Equipment Support-Door
TASK 57-17-11-400-003-A
Installation of the Protective Cover of the ACT-Equipment Support Door
F Fuel Transfer Valve 165QM ** ON A/C NOT FOR ALL
F ACT Fuel-Transfer Valve 165QM ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 28-28-00-860-204-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Obey the fuel safety procedures when you work on the fuel system (Ref. AMM TASK 28-00-00-910-001).
   (2) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (3) On the APU section of overhead panel 25VU make sure that the APU/MASTER SW pushbutton switch is released (the ON legend is off).
   (4) On the FUEL section of HYD/FUEL panel 40VU make sure that all tank pump pushbutton switches are released (the OFF legends are on).
   (5) Put a WARNING NOTICE(S) in position:
  • On the APU section of overhead panel 25VU to tell persons not to operate the APU/MASTER SW pushbutton switch
  • On the FUEL section of panel 40VU to tell persons not to operate the fuel system
  • On the ENG/APU FIRE panel located on overhead panel 20VU to tell persons not to operate the fire extinguishing system
  • On the Additional Center Tank (ACT) control section of panel 28VU to tell persons not to operate the fuel system.
Subtask 28-28-00-865-130-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUACT1/REFUEL & SPLY33QUL29
121VUACT XFR VALVE MAN CTL30QHN29
121VUACT1/CTL & SPLY9QHP29
Subtask 28-28-00-010-104-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the left Main Gear Door for Access (Ref. AMM TASK 32-12-00-010-001).
   (2) Put an ACCESS PLATFORM 1M(3 FT) in position in the left MLG bay.
   (3) Remove the Protective Cover from the ACT-Equipment Support Door (Ref. AMM TASK 57-17-11-000-003).
Subtask 28-28-00-010-104-B ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the left main-gear door for access (Ref. AMM TASK 32-12-00-010-001).
   (2) Put an ACCESS PLATFORM 1M(3 FT) in position in the left MLG bay.
   (3) Remove the ACT equipment-support door (Ref. AMM TASK 57-17-11-000-001).
4. Procedure
Subtask 28-28-00-040-067-A ** ON A/C NOT FOR ALL
A. Deactivation of the ACT Transfer Valve in Valve Closed Position
NOTE: A refuel of the ACT is not possible while ACT Transfer Valve inoperative in valve position CLOSED.
   (1) Disconnect the electrical connectors (4) and (11) from the receptacles of the ACT transfer valve actuator (3).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Safety the electrical connectors (4) and (11) to the adjacent electrical harness with a TIE WRAP(S).
   (4) Remove the nut (8), the bolt (5) and the bonding strap (6) from the actuator (3).
   (5) Do a visual check on the indicator of the Transfer Valve Actuator, to identify the position of the valve:
  • indicator in horizontal position, the transfer valve is OPEN,
  • indicator in vertical position, the transfer valve is CLOSED.
   (6) Loosen the bolt (9) and remove the V-clamp (10) and the ACT Transfer Valve Actuator (3).
     (a) Turn the shaft of the ACT Fuel Transfer Valve to the closed position if necessary.
     (b) Install the T720456 TOOL - VALVE LOCKING on the flange of the ACT transfer valve to lock it in the closed position.
Subtask 28-28-00-040-067-B ** ON A/C NOT FOR ALL
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
A. Deactivation of the ACT Fuel-Transfer Valve in the Closed Position
NOTE: A refuel of the ACT is not possible while ACT fuel-transfer valve is OFF in the CLOSED position.
   (1) Disconnect the electrical connectors (3) and (4) from the receptacles of the ACT transfer-valve actuator (2).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Safety the electrical connectors (3) and (4) to the adjacent electrical harness with a TIE WRAP(S).
   (4) Do a visual check of the indicator of the ACT transfer-valve actuator (2) to identify the position of the valve:
  • Indicator in horizontal position: the transfer valve is OPEN
  • Indicator in vertical position: the transfer valve is CLOSED.
   (5) Cut and discard lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Cut and discard lockwire from the screw (5).
   (6) Loosen the screw (5) and remove the V-clamp (6) and the ACT transfer-valve actuator (2).
   (7) Remove the O-ring (7) and discard it:
     (a) Turn the shaft of the ACT fuel-transfer valve (1) to the closed position, if necessary.
     (b) Install the T720456 TOOL - VALVE LOCKING on the flange of the ACT fuel-transfer valve (1) to lock it in the closed position.
5. Close-up
Subtask 28-28-00-865-131-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUACT1/REFUEL & SPLY33QUL29
121VUACT XFR VALVE MAN CTL30QHN29
121VUACT1/CTL & SPLY9QHP29
Subtask 28-28-00-860-205-A ** ON A/C NOT FOR ALL
B. Put the aircraft back to the serviceable condition.
   (1) Install the Protective Cover on the ACT-Equipment Support Door (Ref. AMM TASK 57-17-11-400-003).
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Remove the access platform(s).
   (4) Close the Main Gear Doors (Ref. AMM TASK 32-12-00-410-001).
   (5) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
   (6) Remove the WARNING NOTICE(S).
   (7) In the cockpit put a placard in position to tell the crew that the ACT fuel-transfer valve is OFF in the closed position.
   (8) On the refuel/defuel control panel 801VU put a placard in position to tell the ground crew: DO NOT REFUEL THE ACT(s).
   (9) Make an entry in the logbook.
Subtask 28-28-00-860-205-B ** ON A/C NOT FOR ALL
B. Put the aircraft back to the serviceable condition.
   (1) Install the ACT equipment-support door (Ref. AMM TASK 57-17-11-400-001).
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Remove the access platform(s).
   (4) Close the main gear doors (Ref. AMM TASK 32-12-00-410-001).
   (5) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
   (6) Remove the WARNING NOTICE(S).
   (7) In the cockpit, put a placard in position to tell the crew that the ACT fuel-transfer valve is OFF in the closed position.
   (8) On refuel/defuel control panel 801VU, put a placard in position to tell the ground crew: DO NOT REFUEL THE ACT(s).
   (9) Make an entry in the logbook.
[Rev.10 from 2021] 2026.04.02 06:17:48 UTC