W DOC AIRBUS | AMM A320F

Deactivation of the ACT Transfer Valve in the Closed Position


TASK 28-28-00-040-012-A
Deactivation of the ACT Transfer Valve in the Closed Position


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
Task Summary
Access Test Specific Tools Mhr E/T Nb Men
NONOYES0.80.81
1. Reason for the Job
MMEL 28-12-05A
OVERPRESSURE PROTECTOR IN ACT (FAA ONLY)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
TIE WRAP(S)
No specific
1
WARNING NOTICE(S)
T720456
1
TOOL - VALVE LOCKING
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 28-00-00-910-001-A
Fuel Safety Procedures
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
TASK 57-17-11-000-003-A
Removal of the Protective Cover of the ACT-Equipment Support Door
TASK 57-17-11-400-003-A
Installation of the Protective Cover of the ACT-Equipment Support Door
3. Job Set-up
Subtask 28-28-00-860-192-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Obey the fuel safety procedures when you work on the fuel system (Ref. AMM TASK 28-00-00-910-001).
   (2) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
   (3) On the APU section of the overhead panel 25VU, make sure that the APU/MASTER SW pushbutton switch is released (the ON legend is off).
   (4) On the FUEL section of the HYD/FUEL panel 40VU, make sure that all tank pump pushbutton switches are released (the OFF legends are on).
   (5) Put a WARNING NOTICE(S) in position:
  • On the APU section of the overhead panel 25VU, to tell persons not to operate the APU/MASTER SW pushbutton switch.
  • On the FUEL section of the panel 40VU, to tell persons not to operate the fuel system.
  • On the ENG/APU FIRE panel located on the overhead panel 20VU, to tell persons not to operate the fire extinguishing system.
Subtask 28-28-00-010-098-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the left Main Gear Door for Access (Ref. AMM TASK 32-12-00-010-001).
   (2) Put an ACCESS PLATFORM 1M(3 FT) in position in the left MLG bay.
   (3) Remove the Protective Cover from the ACT-Equipment Support Door (Ref. AMM TASK 57-17-11-000-003).
Subtask 28-28-00-865-124-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUACT1/REFUEL/VLV33QUL29
121VUACT XFR VALVE MAN CTL30QHN29
121VUACT1/XFR VLV/AUTO CTL9QHP29
4. Procedure
Subtask 28-28-00-040-064-A ** ON A/C NOT FOR ALL
A. Deactivation of the ACT Transfer Valve in Valve Closed Position
NOTE: A refuel of the ACT is not possible while ACT Transfer Valve inoperative in valve position CLOSED.
   (1) Disconnect the electrical connectors (4) and (11) from the receptacles of the ACT transfer valve actuator (3).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Safety the electrical connectors (4) and (11) to the adjacent electrical harness with a TIE WRAP(S).
   (4) Remove the nut (8), the bolt (5) and the bonding strap (6) from the actuator (3).
   (5) Do a visual check on the indicator of the Transfer Valve Actuator, to identify the position of the valve:
  • indicator in horizontal position, the transfer valve is OPEN,
  • indicator in vertical position, the transfer valve is CLOSED.
   (6) Loosen the bolt (9) and remove the V-clamp (10) and the ACT Transfer Valve Actuator (3).
     (a) Turn the shaft of the ACT Fuel Transfer Valve to the closed position if necessary.
     (b) Install the T720456 TOOL - VALVE LOCKING on the flange of the ACT transfer valve to lock it in the closed position.
5. Close-up
Subtask 28-28-00-865-125-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUACT1/REFUEL/VLV33QUL29
121VUACT XFR VALVE MAN CTL30QHN29
121VUACT1/XFR VLV/AUTO CTL9QHP29
Subtask 28-28-00-860-193-A ** ON A/C NOT FOR ALL
B. Put the aircraft back to the serviceable condition.
   (1) Install the Protective Cover on the ACT-Equipment Support Door (Ref. AMM TASK 57-17-11-400-003).
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Remove the access platform(s).
   (4) Close the Main Gear Doors (Ref. AMM TASK 32-12-00-410-001).
   (5) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
   (6) Remove the WARNING NOTICE(S).
   (7) In the cockpit, put a placard in position to tell the crew that the ACT Transfer Valve is inoperative in valve position CLOSED.
   (8) On the Refuel/Defuel Control Panel 801VU, put a placard in position to tell the ground crew: DO NOT REFUEL THE ACT(s).
   (9) Make an entry in the logbook.
[Rev.9 from 2019] 2026.04.02 06:17:50 UTC