Deactivation of the ACT Transfer Valve in the Closed Position
TASK 28-28-00-040-009-A
Deactivation of the ACT Transfer Valve in the Closed Position
MMEL 28-28-01C
ACT AUTO TRANSFER SYSTEM
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 28-28-00-860-160-A ** ON A/C NOT FOR ALL
Subtask 28-28-00-040-058-A ** ON A/C NOT FOR ALL
Subtask 28-28-00-865-107-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:47 UTC
Deactivation of the ACT Transfer Valve in the Closed Position
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
Task Summary
1. Reason for the Job| Access | Test | Specific Tools | Mhr | E/T | Nb Men |
|---|---|---|---|---|---|
| NO | NO | YES | 0.8 | 0.8 | 1 |
MMEL 28-28-01C
ACT AUTO TRANSFER SYSTEM
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | TIE WRAP(S) |
| No specific | 1 | WARNING NOTICE(S) |
| T720456 | 1 | TOOL - VALVE LOCKING |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
| TASK 57-17-11-000-003-A | Removal of the Protective Cover of the ACT-Equipment Support Door |
| TASK 57-17-11-400-003-A | Installation of the Protective Cover of the ACT-Equipment Support Door |
Subtask 28-28-00-860-160-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Obey the fuel safety procedures when you work on the fuel system (Ref. AMM TASK 28-00-00-910-001).
(2) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
(3) On the APU section of the overhead panel 25VU, make sure that the APU/MASTER SW pushbutton switch is released (the ON legend is off).
(4) On the FUEL section of the HYD/FUEL panel 40VU, make sure that all tank pump pushbutton switches are released (the OFF legends are on).
(5) Put a WARNING NOTICE(S) in position:
Subtask 28-28-00-010-083-A ** ON A/C NOT FOR ALL (1) Obey the fuel safety procedures when you work on the fuel system (Ref. AMM TASK 28-00-00-910-001).
(2) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
(3) On the APU section of the overhead panel 25VU, make sure that the APU/MASTER SW pushbutton switch is released (the ON legend is off).
(4) On the FUEL section of the HYD/FUEL panel 40VU, make sure that all tank pump pushbutton switches are released (the OFF legends are on).
(5) Put a WARNING NOTICE(S) in position:
- On the APU section of the overhead panel 25VU, to tell persons not to operate the APU/MASTER SW pushbutton switch.
- On the FUEL section of the panel 40VU, to tell persons not to operate the fuel system.
- On the ENG/APU FIRE panel located on the overhead panel 20VU, to tell persons not to operate the fire extinguishing system.
B. Get Access
(1) Open the left Main Gear Door for Access (Ref. AMM TASK 32-12-00-010-001).
(2) Put an ACCESS PLATFORM 1M(3 FT) in position in the left MLG bay.
(3) Remove the Protective Cover from the ACT-Equipment Support Door (Ref. AMM TASK 57-17-11-000-003).
Subtask 28-28-00-865-106-A ** ON A/C NOT FOR ALL (1) Open the left Main Gear Door for Access (Ref. AMM TASK 32-12-00-010-001).
(2) Put an ACCESS PLATFORM 1M(3 FT) in position in the left MLG bay.
(3) Remove the Protective Cover from the ACT-Equipment Support Door (Ref. AMM TASK 57-17-11-000-003).
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ACT1/REFUEL & SPLY | 33QU | L29 |
| 121VU | ACT XFR VALVE MAN CTL | 30QH | N29 |
| 121VU | ACT1/CTL & SPLY | 9QH | P29 |
Subtask 28-28-00-040-058-A ** ON A/C NOT FOR ALL
A. Deactivation of the ACT Transfer Valve in Valve Closed Position
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Safety the electrical connectors (4) and (11) to the adjacent electrical harness with a TIE WRAP(S).
(4) Remove the nut (8), the bolt (5) and the bonding strap (6) from the actuator (3).
(5) Do a visual check on the indicator of the Transfer Valve Actuator, to identify the position of the valve:
(a) Turn the shaft of the ACT Fuel Transfer Valve to the closed position if necessary.
(b) Install the T720456 TOOL - VALVE LOCKING on the flange of the ACT transfer valve to lock it in the closed position.
5. Close-upNOTE: A refuel of the ACT is not possible while ACT Transfer Valve inoperative in valve position CLOSED.
(1) Disconnect the electrical connectors (4) and (11) from the receptacles of the ACT transfer valve actuator (3). (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Safety the electrical connectors (4) and (11) to the adjacent electrical harness with a TIE WRAP(S).
(4) Remove the nut (8), the bolt (5) and the bonding strap (6) from the actuator (3).
(5) Do a visual check on the indicator of the Transfer Valve Actuator, to identify the position of the valve:
- indicator in horizontal position, the transfer valve is OPEN,
- indicator in vertical position, the transfer valve is CLOSED.
(a) Turn the shaft of the ACT Fuel Transfer Valve to the closed position if necessary.
(b) Install the T720456 TOOL - VALVE LOCKING on the flange of the ACT transfer valve to lock it in the closed position.
Subtask 28-28-00-865-107-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 28-28-00-860-161-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ACT1/REFUEL & SPLY | 33QU | L29 |
| 121VU | ACT XFR VALVE MAN CTL | 30QH | N29 |
| 121VU | ACT1/CTL & SPLY | 9QH | P29 |
B. Put the aircraft back to the serviceable condition.
(1) Install the Protective Cover on the ACT-Equipment Support Door (Ref. AMM TASK 57-17-11-400-003).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the access platform(s).
(4) Close the Main Gear Doors (Ref. AMM TASK 32-12-00-410-001).
(5) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(6) Remove the WARNING NOTICE(S).
(7) In the cockpit, put a placard in position to tell the crew that the ACT Transfer Valve is inoperative in valve position CLOSED.
(8) On the Refuel/Defuel Control Panel 801VU, put a placard in position to tell the ground crew: DO NOT REFUEL THE ACT(s).
(9) Make an entry in the logbook.
(1) Install the Protective Cover on the ACT-Equipment Support Door (Ref. AMM TASK 57-17-11-400-003).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the access platform(s).
(4) Close the Main Gear Doors (Ref. AMM TASK 32-12-00-410-001).
(5) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(6) Remove the WARNING NOTICE(S).
(7) In the cockpit, put a placard in position to tell the crew that the ACT Transfer Valve is inoperative in valve position CLOSED.
(8) On the Refuel/Defuel Control Panel 801VU, put a placard in position to tell the ground crew: DO NOT REFUEL THE ACT(s).
(9) Make an entry in the logbook.
Fuel Transfer Valve 165QM