ADDITIONAL CENTER TANK TRANSFER SYSTEM
-
28-28-00-040-001-A
[10]
Deactivation of the Fuel Transfer Valve -
28-28-00-040-003-A
[10]
Deactivation of the Vent Valve in the Open Position -
28-28-00-040-004-A
[10]
Deactivation of the ACT Fuel Inlet Valve -
28-28-00-040-005-A
[10]
Deactivation of the FWD ACT's Isolation Valve in the Closed Position -
28-28-00-040-006-A
[10]
Check of the Integrated Impact Wall for Permissible Damage -
28-28-00-040-007-A
[10]
Deactivation of the Vent Valve in the Closed Position -
28-28-00-040-008-A
[10]
Deactivation of the ACT Transfer Valve in the Closed Position -
28-28-00-040-009-A
[10]
Deactivation of the ACT Transfer Valve in the Closed Position -
28-28-00-040-010-A
[10]
Deactivation of the ACT Transfer Valve in the Closed Position -
28-28-00-040-011-A
[10]
Deactivation of the ACT Transfer Valve in the Closed Position -
28-28-00-040-012-A
[9]
Deactivation of the ACT Transfer Valve in the Closed Position -
28-28-00-040-014-A
[10]
Deactivation of the ACT Transfer Valve in the Closed Position -
28-28-00-040-015-A
[10]
Deactivation of the ACT Transfer Valve in the Closed Position -
28-28-00-040-016-A
[10]
Deactivation of the ACT Transfer Valve in the Closed Position -
28-28-00-040-017-A
[10]
Deactivation of the ACT Transfer Valve in the Closed Position -
28-28-00-040-018-A
[10]
Deactivation of the ACT Transfer Valve in the Closed Position -
28-28-00-040-019-A
[10]
Deactivation of the ACT Transfer Valve in the Closed Position -
28-28-00-040-020-A
[10]
Deactivation of the ACT Transfer Valve in the Closed Position -
28-28-00-200-002-A
[10]
General Visual Inspection of the Integrated Impact Wall(s) and Pipework Protection Cover (If Installed) -
28-28-00-200-003-A
[10]
Operational Check of the Leak Monitor for the Indication of Fuel Leakage -
28-28-00-200-004-A
[10]
Detailed Inspection of Additional Center Tank (ACT), External Surface -
28-28-00-200-005-A
[10]
Detailed Inspection of Additional Center Tank (ACT), Internal Structure -
28-28-00-200-008-A
[10]
Special Detailed Inspection (HFEC) of Additional Center Tank (ACT), External Surface, in Area of Tankplate Profiles -
28-28-00-200-009-B
[10]
General Visual Inspection of the Forward ACT Isolation-Valve for the Closed Position -
28-28-00-220-001-A
[10]
Inspection of Additional Center Tank (ACT), External Surface, in Area of Tankplate Profiles -
28-28-00-440-001-A
[10]
Reactivation of the Fuel Transfer Valve -
28-28-00-440-003-A
[10]
Reactivation of the Vent Valve -
28-28-00-440-004-A
[10]
Reactivation of the ACT Fuel Inlet Valve -
28-28-00-440-005-A
[10]
Reactivation of the FWD ACT's Isolation Valve -
28-28-00-440-006-A
[10]
Reactivation of the Vent Valve -
28-28-00-440-007-A
[10]
Reactivation of the ACT Transfer Valve -
28-28-00-440-009-A
[10]
Reactivation of the ACT Transfer Valve -
28-28-00-440-010-A
[10]
Reactivation of the ACT Transfer Valve -
28-28-00-440-011-A
[10]
Reactivation of the ACT Transfer Valve -
28-28-00-440-012-A
[9]
Reactivation of the ACT Transfer Valve -
28-28-00-440-014-A
[10]
Reactivation of the ACT Transfer Valve -
28-28-00-440-015-A
[10]
Reactivation of the ACT Transfer Valve -
28-28-00-440-016-A
[10]
Reactivation of the ACT Transfer Valve -
28-28-00-440-017-A
[10]
Reactivation of the ACT Transfer Valve -
28-28-00-440-018-A
[10]
Reactivation of the ACT Transfer Valve -
28-28-00-440-019-A
[10]
Reactivation of the ACT Transfer Valve -
28-28-00-440-020-A
[10]
Reactivation of the ACT Transfer Valve -
28-28-00-550-001-A
[10]
Preparation for Transportation of the Additional Center Tank(s) as Air Cargo -
28-28-00-550-002-A
[10]
Additional Center Tank (ACT) Storage / ACT Back Into Service -
28-28-00-610-001-A
[10]
Preservation of the unused Additional Center Tank (ACT)(s) installed in the Aircraft -
28-28-00-710-001-A
[10]
Operational Check of the ACT Manual Transfer System -
28-28-00-710-002-A
[10]
Operational Check of Motor 1 of Transfer Valve -
28-28-00-710-003-A
[10]
Operational Test of the ACT Fuel Transfer-Pump Pressure Switch -
28-28-00-710-004-A
[10]
Operational Test of the ACT Automatic Transfer System -
28-28-00-710-005-A
[10]
Operational Test of the Additional Center Tank (ACT) Automatic Transfer System -
28-28-00-710-006-A
[10]
Operational Test of the ACT Vent Valve Actuator -
28-28-00-710-008-A
[10]
Operational Check of the ACT Manual Transfer System (AFT Cargo-Compartment) -
28-28-00-710-010-A
[10]
Operational Check of Forward ACT Vent Isolation Valve -
28-28-00-710-012-A
[10]
Operational Check of Forward ACT Isolation Valve -
28-28-00-710-013-A
[10]
Operational Check of the Pressure Holding Valves -
28-28-00-710-015-A
[10]
Remove and Carry out Operational Check of Vent Line Check Valves -
28-28-00-710-016-A
[10]
Operational Test of the ACT Pressure Holding Valves -
28-28-00-710-802-A
[10]
Operational Check of ACT FWD (4.1) Overpressure Protector -
28-28-00-710-803-A
[10]
Operational Check of ACT Transfer Pump GFI (SFAR 88) -
28-28-00-720-001-A
[10]
Functional Check of ACT Pressure Reducing Valve -
28-28-00-720-002-A
[10]
Operational Check of ACT(S) Inward Relief Valve -
28-28-00-720-004-A
[10]
Functional Test of the ACT Inlet Valves -
28-28-00-720-005-A
[10]
Functional Test of the Check Valves of the ACT -
28-28-00-720-006-A
[10]
Functional Test of the Check Valves of the ACT -
28-28-00-740-801-A
[10]
Read CFDIU Display for Faults -
28-28-00-790-001-A
[10]
Leak Test of the Additional Center Tank (ACT) Fuel/Vent System and Pressurization System -
28-28-00-790-002-A
[10]
Leak Test of the Inner Manhole Cover -
28-28-00-790-003-A
[10]
Leak Test of the Outer Manhole Cover -
28-28-00-790-004-A
[10]
Functional Check of the Vent/Transfer Pipe Shrouds and ACT Drain Pipe Connectors -
28-28-00-790-005-A
[10]
Leak Test of ACT Vent/Transfer Pipe-Shrouds and Cavity Drain Lines -
28-28-00-790-802-A
[10]
Functional Check for Leakage of the Vent/Transfer Inner Pipes and the ACT(s) Bladder -
28-28-00-790-803-A
[10]
Functional Check for Leakage of the ACT Pressurization System -
28-28-00-790-804-A
[10]
Functional Check for Leakage of the Vent/Transfer Pipe Shrouds, the ACT Tank Casing and the ACT Drain System -
28-28-00-860-802-A
[10]
ACT Vent Valve - Simulation Fully Open with Vent Valve Deactivated -
28-28-00-920-002-A
[10]
Replacement of the Relay 98QH