3. Job Set-up
Subtask 28-25-71-941-052-A ** ON A/C NOT FOR ALL
Subtask 28-25-71-020-050-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 07:25:16 UTC
Removal of the Micro-switch
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 20QU
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | WARNING NOTICE(S) |
| 98D27803500001 | 1 | LOCKING TOOL ZERO POS |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 622KB | |
| 192MB |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 28-25-71-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 28-25-71-941-052-B ** ON A/C NOT FOR ALL (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
A. Safety Precautions
(1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Put the WARNING NOTICE(S) in position to tell persons not to operate the slats.
Subtask 28-25-71-860-050-B ** ON A/C NOT FOR ALL (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(2) Put the WARNING NOTICE(S) in position to tell persons not to operate the slats.
B. Aircraft Maintenance Configuration
(1) Install the 98D27803500001 LOCKING TOOL ZERO POS on the slat/flap control lever.
Subtask 28-25-71-010-050-A ** ON A/C NOT FOR ALL (1) Install the 98D27803500001 LOCKING TOOL ZERO POS on the slat/flap control lever.
C. Get Access
(1) Open the access door 192MB.
Subtask 28-25-71-010-050-B ** ON A/C NOT FOR ALL (1) Open the access door 192MB.
NOTE: If operating in battery power, do not keep the door open longer than necessary because the battery can discharge.
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) in position below zone 622.
(2) Open the access door 622KB.
Subtask 28-25-71-865-050-A (1) Put the ACCESS PLATFORM 3M (10 FT) in position below zone 622.
(2) Open the access door 622KB.
NOTE: If operating in battery power, do not keep the door open longer than necessary because the battery can discharge.
D. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FUEL/FQI/CHAN/1 | 1QT | A13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L26 |
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| ** ON A/C ALL | |||
| 121VU | FUEL/FQI/CHAN/2 | 2QT | M27 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L25 |
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L23 |
| ** ON A/C ALL | |||
| 122VU | ELEC/REFLNG/NORM | 2PR | S27 |
| 122VU | ELEC/RFL/SPLY/LOGIC | 4PR | U29 |
| 122VU | ELEC/REFLNG/ON/BAT | 1PR | U28 |
Subtask 28-25-71-020-050-B ** ON A/C NOT FOR ALL
A. Removal of the Micro-switch 20QU
(2) Disconnect the electrical connector (1) from the micro-switch (7).
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(4) Remove and discard the lockwire from the locknut (6) and the lockwasher (5).
(5) Remove the locknut (6), the lockwasher (5) and the position-washer (4) from the microswitch (7).
(6) Carefully remove the micro-switch (7) from the bracket (2).
Subtask 28-25-71-020-050-C ** ON A/C NOT FOR ALL WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(1) Remove the cable-tie that holds the support cable and the connector-plug (1) in position. (2) Disconnect the electrical connector (1) from the micro-switch (7).
(3) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(4) Remove and discard the lockwire from the locknut (6) and the lockwasher (5).
(5) Remove the locknut (6), the lockwasher (5) and the position-washer (4) from the microswitch (7).
(6) Carefully remove the micro-switch (7) from the bracket (2).
A. Removal of the Micro-switch 20QU
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove and discard the lockwire from the locknut (4) and the lockwasher (3).
(4) Remove the locknut (4), the lockwasher (3) and the position-washer (2) from the microswitch (1).
(5) Carefully remove the micro-switch (1) from the bracket (10).
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(1) Disconnect the electrical connector (11) from the micro-switch (1). (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Remove and discard the lockwire from the locknut (4) and the lockwasher (3).
(4) Remove the locknut (4), the lockwasher (3) and the position-washer (2) from the microswitch (1).
(5) Carefully remove the micro-switch (1) from the bracket (10).
Micro-switch 20QU