Installation of the Air-Inlet Valve
TASK 28-25-57-400-001-A
Installation of the Air-Inlet Valve
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 28-25-57-941-054-A ** ON A/C NOT FOR ALL
Subtask 28-25-57-420-051-A ** ON A/C NOT FOR ALL
Subtask 28-25-57-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:44 UTC
Installation of the Air-Inlet Valve
WARNING:
MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING NOTICES ARE IN POSITION.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY BARRIER(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.01ABA1) | Turbine Fuel-- Kerosene - |
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-11-28-650-003-A | Pressure Refuel with Automatic Control |
| TASK 20-28-00-912-802-A | Electrical Bonding - General Maintenance Procedure |
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 28-25-00-650-003-A | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-650-003-A-01 | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-869-001-A | Fuel Transfer |
| TASK 28-25-42-000-001-A | Removal of the Refuel Diffuser Assembly - Wing Tanks |
| TASK 28-25-42-400-001-A | Installation of the Refuel Diffuser Assembly - Wing Tanks |
| TASK 57-27-11-000-002-A | Removal of the Access Panel |
| TASK 57-27-11-400-002-A | Installation of the Access Panel |
Subtask 28-25-57-941-054-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) Make sure that the SAFETY BARRIER(S) are in position.
Subtask 28-25-57-860-051-A ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
(1) You must obey the fuel safety procedures (Ref. AMM TASK 28-10-00-910-001) when you do work in a fuel tank. (2) Make sure that the SAFETY BARRIER(S) are in position.
B. Aircraft Maintenance Configuration
(1) Make sure that the applicable fuel tank is defueled (Ref. AMM TASK 28-25-00-650-001).
(2) Make sure that the remaining fuel has been drained from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
(3) Make sure that the access platform is below the applicable access panel 540KB (640KB).
(4) Make sure that the applicable access panel 540KB (640KB) is removed (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-002).
(5) Make sure that the applicable refuel diffuser is removed (Ref. AMM TASK 28-25-42-000-001).
4. Procedure(1) Make sure that the applicable fuel tank is defueled (Ref. AMM TASK 28-25-00-650-001).
(2) Make sure that the remaining fuel has been drained from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
(3) Make sure that the access platform is below the applicable access panel 540KB (640KB).
(4) Make sure that the applicable access panel 540KB (640KB) is removed (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-002).
(5) Make sure that the applicable refuel diffuser is removed (Ref. AMM TASK 28-25-42-000-001).
Subtask 28-25-57-420-051-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
(1) Clean the component interfaces and the adjacent areas with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
Subtask 28-25-57-420-050-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent areas with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
B. Installation of the Air-Inlet Valve 161QM (162QM)
(1) Remove the blanking plugs from the disconnected pipe (1) end and the air-inlet valve (7).
(2) Use the bolts (5) to install the air-inlet valve (7) on the bracket (6). Tighten the bolts (5).
(3) Lubricate the union (8) with Turbine Fuel-- Kerosene - (Material No.01ABA1)
(4) Use the union (8) to connect the pipe (1) to the air-inlet valve (7). Tighten the union (8).
(5) Use the bolt (3) and the nut (4) to connect the bonding lead (2) to the air-inlet valve (7). Tighten the nut (4).
(6) Do a bonding check of the bonding lead (2) (Ref. AMM TASK 20-28-00-912-802).
(7) Install the refuel diffuser (Ref. AMM TASK 28-25-42-400-001).
5. Close-up(1) Remove the blanking plugs from the disconnected pipe (1) end and the air-inlet valve (7).
(2) Use the bolts (5) to install the air-inlet valve (7) on the bracket (6). Tighten the bolts (5).
(3) Lubricate the union (8) with Turbine Fuel-- Kerosene - (Material No.01ABA1)
(4) Use the union (8) to connect the pipe (1) to the air-inlet valve (7). Tighten the union (8).
(5) Use the bolt (3) and the nut (4) to connect the bonding lead (2) to the air-inlet valve (7). Tighten the nut (4).
(6) Do a bonding check of the bonding lead (2) (Ref. AMM TASK 20-28-00-912-802).
(7) Install the refuel diffuser (Ref. AMM TASK 28-25-42-400-001).
Subtask 28-25-57-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panels 540KB (640KB) (Ref. AMM TASK 57-27-11-400-002).
Subtask 28-25-57-650-052-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panels 540KB (640KB) (Ref. AMM TASK 57-27-11-400-002).
B. Fuel Configuration
(1) Refuel, defuel or transfer fuel as necessary (Ref. AMM TASK 12-11-28-650-003), (Ref. AMM TASK 28-25-00-650-001) or (Ref. AMM TASK 28-25-00-869-001).
Subtask 28-25-57-942-050-A ** ON A/C NOT FOR ALL (1) Refuel, defuel or transfer fuel as necessary (Ref. AMM TASK 12-11-28-650-003), (Ref. AMM TASK 28-25-00-650-001) or (Ref. AMM TASK 28-25-00-869-001).
C. Removal of Equipment
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the safety barriers.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the safety barriers.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Air-Inlet Valve