Removal of the Refuel Panel
TASK 28-25-55-000-001-A
Removal of the Refuel Panel
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-25-55-941-051-A
Subtask 28-25-55-020-050-A
[Rev.10 from 2021]
2026.04.02 06:17:43 UTC
Removal of the Refuel Panel
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
FIN: 800VU
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 622KB | |
| 192MB |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 28-25-55-941-051-A
A. Safety Precautions
(1) Put the SAFETY BARRIER(S) in position.
Subtask 28-25-55-010-050-A ** ON A/C NOT FOR ALL (1) Put the SAFETY BARRIER(S) in position.
B. Get Access
(1) Open access door 192MB.
Subtask 28-25-55-010-050-C ** ON A/C NOT FOR ALL (1) Open access door 192MB.
NOTE: If you operate the access door with the battery power, Airbus recommends you not to keep the door open for a longer time than necessary.
If you operate the door for a longer time, the power of the battery will decrease.
If you operate the door for a longer time, the power of the battery will decrease.
B. Get Access
(1) Install the ACCESS PLATFORM 3M (10 FT) below zone 622.
(2) Open the access panel 622KB.
Subtask 28-25-55-865-050-A (1) Install the ACCESS PLATFORM 3M (10 FT) below zone 622.
(2) Open the access panel 622KB.
NOTE: If operating in battery power, do not keep the door open longer than necessary because the battery can discharge.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L23 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L22 |
Subtask 28-25-55-020-050-A
A. Removal of the Refuel Panel 800VU
(2) Disconnect the electrical connectors (1) and (2) from the refuel panel (3).
(3) Put CAP - BLANKING on the disconnected electrical connectors (1) and (2) and the refuel panel (3).
CAUTION:
DO NOT PULL THE PANEL TOO FAR AND DO NOT LET IT HANG ON THE ELECTRICAL CABLES. THIS CAN CAUSE DAMAGE TO THE ELECTRICAL CABLES.
(1) Release the fasteners (4) and carefully remove the refuel panel (3) from the instrument rack. (2) Disconnect the electrical connectors (1) and (2) from the refuel panel (3).
(3) Put CAP - BLANKING on the disconnected electrical connectors (1) and (2) and the refuel panel (3).
Refuel Panel 800VU