Installation of the Center-Tank Defuel/Transfer Valve-Actuator
TASK 28-25-53-400-001-A
Installation of the Center-Tank Defuel/Transfer Valve-Actuator
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Expendable Parts
D. Referenced Information
3. Job Set-up
Subtask 28-25-53-860-052-A
Subtask 28-25-53-210-051-A
Subtask 28-25-53-410-054-A
[Rev.10 from 2021]
2026.04.02 07:03:12 UTC
Installation of the Center-Tank Defuel/Transfer Valve-Actuator
FIN: 11QU
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 0.143 and 0.117 m.daN (12.65 and 10.35 lbf.in ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.03KGB1) | Fluorosilicone base Grease-- PTFE Thickened High Temp. - |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 2 | 0-RING | AIPC 28-25-03-02-130 |
| 2 | O-RING | AIPC 28-25-83-02-140 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
Subtask 28-25-53-860-052-A
A. Aircraft Maintenance Configuration
(1) On the refuel/defuel control panel 800VU, make sure that:
(3) Make sure that the MLG doors are open (Ref. AMM TASK 32-12-00-010-001).
(4) Make sure that the access door 192MB is open.
(5) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the MLG door.
Subtask 28-25-53-865-051-A (1) On the refuel/defuel control panel 800VU, make sure that:
- the MODE SELECT switch is set to OFF,
- the OPEN warning light is off.
(3) Make sure that the MLG doors are open (Ref. AMM TASK 32-12-00-010-001).
(4) Make sure that the access door 192MB is open.
(5) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the MLG door.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L23 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L22 |
Subtask 28-25-53-210-051-A
A. Preparation for Installation
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the blanking caps from the mounting flange (1) and from the defuel/transfer valve-actuator (5).
(4) Make sure that the defuel/transfer valve actuator (5) is in this configuration:
Subtask 28-25-53-420-053-A (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the blanking caps from the mounting flange (1) and from the defuel/transfer valve-actuator (5).
(4) Make sure that the defuel/transfer valve actuator (5) is in this configuration:
- the see-feel indicator (4) is in-line with the step (valve open).
NOTE: The drive key (7) and the indicator groove (8) of the drive spindle are 90 deg. inverted to the see-feel indicator (4).
B. Installation of the Defuel/Transfer Valve-Actuator (11QU)
(1) Put a new AIPC 28-25-03-02-130 0-RING (2) or AIPC 28-25-83-02-140 O-RING (2) with a thin layer of Fluorosilicone base Grease-- PTFE Thickened High Temp. - (Material No.03KGB1) on the mounting flange (1).
(2) Make sure that the defuel/transfer valve actuator (5) and the drive spindle (8) stay in the correct configuration.
(3) Connect the drive key (7) into the drive spindle (8).
(4) Turn the defuel/transfer valve actuator (5) clockwise until the dowel in the flange of the actuator engages with the slot on the mounting flange (1).
(5) Install the V-clamp (3).
(7) Remove the blanking caps from the electrical connectors.
(8) Make sure that all the electrical connections are clean and in the correct condition.
(9) Connect the electrical connector (6) to the defuel/transfer valve actuator (5).
Subtask 28-25-53-860-051-A (1) Put a new AIPC 28-25-03-02-130 0-RING (2) or AIPC 28-25-83-02-140 O-RING (2) with a thin layer of Fluorosilicone base Grease-- PTFE Thickened High Temp. - (Material No.03KGB1) on the mounting flange (1).
(2) Make sure that the defuel/transfer valve actuator (5) and the drive spindle (8) stay in the correct configuration.
(3) Connect the drive key (7) into the drive spindle (8).
(4) Turn the defuel/transfer valve actuator (5) clockwise until the dowel in the flange of the actuator engages with the slot on the mounting flange (1).
(5) Install the V-clamp (3).
CAUTION:
DO NOT TORQUE THE V-CLAMP(S) TO MORE THAN THE SPECIFIED VALUE. THIS CAN CAUSE DAMAGE TO THE FLANGE SURFACES.
(6) TORQUE the screw (7) Remove the blanking caps from the electrical connectors.
(8) Make sure that all the electrical connections are clean and in the correct condition.
(9) Connect the electrical connector (6) to the defuel/transfer valve actuator (5).
C. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 28-25-53-865-053-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 28-25-53-710-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L23 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L22 |
E. Test.
5. Close-up| ACTION | RESULT |
|---|---|
1.On the refuel/defuel control panel 800VU:
| On the refuel/defuel control panel 800VU:
|
2.On the refuel/defuel control panel 800VU:
| On the refuel/defuel control panel 800VU:
|
Subtask 28-25-53-410-054-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 192MB.
(3) Close the MLG doors (Ref. AMM TASK 32-12-00-410-001).
(4) Remove the access platform(s).
(5) Remove the WARNING NOTICE(S).
Subtask 28-25-53-860-050-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 192MB.
(3) Close the MLG doors (Ref. AMM TASK 32-12-00-410-001).
(4) Remove the access platform(s).
(5) Remove the WARNING NOTICE(S).

Transfer Defuel-Valve Actuator - Center Tank.