Removal of the Refuel/Defuel Coupling/Cap
TASK 28-25-41-000-001-A
Removal of the Refuel/Defuel Coupling/Cap
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 28-25-41-941-059-A
Subtask 28-25-41-020-054-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:39 UTC
Removal of the Refuel/Defuel Coupling/Cap
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 622KB | |
| 192MB | |
| FOR [100QM] (COUPLING-REFUEL/DEFUEL, L) | |
| 540JB | |
| FOR [100QM] (COUPLING-REFUEL/DEFUEL, L) | |
| FOR [101QM] (CAP-REFUEL/DEFUEL COUPLING, L) | |
| 522FB, 522HB, 522JB | |
| FOR [40QM] (CPLG-REFUEL/DEFUEL, R) | |
| 640JB | |
| FOR [40QM] (CPLG-REFUEL/DEFUEL, R) | |
| FOR [41QM] (CAP-REFUEL/DEFUEL COUPLING, R) | |
| 622FB, 622HB, 622JB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| FOR [100QM] (COUPLING-REFUEL/DEFUEL, L) | |
| TASK 57-27-11-000-002-A | Removal of the Access Panel |
| FOR [100QM] (COUPLING-REFUEL/DEFUEL, L) | |
| FOR [101QM] (CAP-REFUEL/DEFUEL COUPLING, L) | |
| TASK 57-41-37-000-006-A | Removal of the Access Panels |
| FOR [40QM] (CPLG-REFUEL/DEFUEL, R) | |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 57-27-11-000-002-A | Removal of the Access Panel |
| FOR [40QM] (CPLG-REFUEL/DEFUEL, R) | |
| FOR [41QM] (CAP-REFUEL/DEFUEL COUPLING, R) | |
| TASK 57-41-37-000-006-A | Removal of the Access Panels |
Subtask 28-25-41-941-059-A
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
Subtask 28-25-41-865-055-A WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
(1) You must obey the fuel safety procedures when you do work in the fuel tank (Ref. AMM TASK 28-10-00-910-001). (2) Put the SAFETY BARRIER(S) in position.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 28-25-41-010-050-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L23 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L22 |
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable access panel.
(2) Remove the applicable access panels:
(a) FOR [40QM] (CPLG-REFUEL/DEFUEL, R), [41QM] (CAP-REFUEL/DEFUEL COUPLING, R)
Remove 622FB 622HB and 622JB (Ref. AMM TASK 57-41-37-000-006).
(b) FOR [100QM] (COUPLING-REFUEL/DEFUEL, L), [101QM] (CAP-REFUEL/DEFUEL COUPLING, L)
Remove 522FB 522HB and 522JB (Ref. AMM TASK 57-41-37-000-006).
(3) Remove the applicable access panel (Ref. AMM TASK 28-10-00-910-002):
(a) FOR [40QM] (CPLG-REFUEL/DEFUEL, R)
Remove 640JB (Ref. AMM TASK 57-27-11-000-002).
(b) FOR [100QM] (COUPLING-REFUEL/DEFUEL, L)
Remove 540JB (Ref. AMM TASK 57-27-11-000-002).
Subtask 28-25-41-010-050-C ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable access panel.
(2) Remove the applicable access panels:
(a) FOR [40QM] (CPLG-REFUEL/DEFUEL, R), [41QM] (CAP-REFUEL/DEFUEL COUPLING, R)
Remove 622FB 622HB and 622JB (Ref. AMM TASK 57-41-37-000-006).
(b) FOR [100QM] (COUPLING-REFUEL/DEFUEL, L), [101QM] (CAP-REFUEL/DEFUEL COUPLING, L)
Remove 522FB 522HB and 522JB (Ref. AMM TASK 57-41-37-000-006).
(3) Remove the applicable access panel (Ref. AMM TASK 28-10-00-910-002):
(a) FOR [40QM] (CPLG-REFUEL/DEFUEL, R)
Remove 640JB (Ref. AMM TASK 57-27-11-000-002).
(b) FOR [100QM] (COUPLING-REFUEL/DEFUEL, L)
Remove 540JB (Ref. AMM TASK 57-27-11-000-002).
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable access panel.
(2) Remove the access panels:
(a) FOR [40QM] (CPLG-REFUEL/DEFUEL, R), [41QM] (CAP-REFUEL/DEFUEL COUPLING, R)
Remove 622FB 622HB and 622JB (Ref. AMM TASK 57-41-37-000-006).
(3) Remove the applicable access panels:
(a) FOR [40QM] (CPLG-REFUEL/DEFUEL, R)
Remove 640JB (Ref. AMM TASK 57-27-11-000-002) and (Ref. AMM TASK 28-10-00-910-002).
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT) in position below the applicable access panel.
(2) Remove the access panels:
(a) FOR [40QM] (CPLG-REFUEL/DEFUEL, R), [41QM] (CAP-REFUEL/DEFUEL COUPLING, R)
Remove 622FB 622HB and 622JB (Ref. AMM TASK 57-41-37-000-006).
(3) Remove the applicable access panels:
(a) FOR [40QM] (CPLG-REFUEL/DEFUEL, R)
Remove 640JB (Ref. AMM TASK 57-27-11-000-002) and (Ref. AMM TASK 28-10-00-910-002).
Subtask 28-25-41-020-054-B ** ON A/C NOT FOR ALL
A. Removal of the Refuel/Defuel Coupling-Cap
(1) Remove the refuel coupling-cap (7) from the coupling (4).
(2) Disconnect the chain (6) from the lug (5).
(4) If it is necessary to replace the chain assembly (13), do these steps that follow:
(a) Remove the screws (11) from the cap (7).
(b) Remove and discard the chain assembly (13).
(c) Clean the screw location holes on the cap (7) and the screws (11) with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(a) Open the access door 192MB.
(b) On the refuel/defuel panel 800VU:
1 Put the MODE SELECT switch in the OFF position and lower the guard.
a Make sure that the DEFUEL/XFR valve is in shut position (light 21QU goes off).
2 Put all the REFUEL VALVES switches in the NORM position and lower the guard.
(c) Close the access door 192MB.
(8) Remove the coupling (4).
(9) Discard the coupling (4) if it is to be replaced.
(10) Put blanking plugs on the disconnected line ends.
(11) Remove and discard the O-rings (2) and (10).
Subtask 28-25-41-020-054-E ** ON A/C NOT FOR ALL (1) Remove the refuel coupling-cap (7) from the coupling (4).
(2) Disconnect the chain (6) from the lug (5).
NOTE: The chain (6) is spring-loaded in to a protection sleeve on the cap (7).
(3) Put a container below the coupling (4). Operate the coupling check-valve by hand to drain all remaining fuel. Remove the container. (4) If it is necessary to replace the chain assembly (13), do these steps that follow:
(a) Remove the screws (11) from the cap (7).
(b) Remove and discard the chain assembly (13).
(c) Clean the screw location holes on the cap (7) and the screws (11) with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
NOTE: It is possible that there is a washer behind the nuts (3) and (8). You will subsequently remove and retain the washer(s).
(5) Do the steps that follow: (a) Open the access door 192MB.
(b) On the refuel/defuel panel 800VU:
1 Put the MODE SELECT switch in the OFF position and lower the guard.
a Make sure that the DEFUEL/XFR valve is in shut position (light 21QU goes off).
2 Put all the REFUEL VALVES switches in the NORM position and lower the guard.
(c) Close the access door 192MB.
NOTE: If operating in battery power, do not keep the door open longer than necessary because the battery can discharge.
(6) For the bolts (1) and (9) where there is a washer behind the nuts (3) and (8): - Make a temporary mark on the coupling (4), so that you can install the same washer in the same position.
(8) Remove the coupling (4).
(9) Discard the coupling (4) if it is to be replaced.
(10) Put blanking plugs on the disconnected line ends.
(11) Remove and discard the O-rings (2) and (10).
A. Removal of the Refuel/Defuel Coupling-Cap
(1) Remove the refuel coupling-cap (7) from the coupling (4).
(2) Disconnect the chain (6) from the lug (5).
(4) If it is necessary to replace the chain assembly (13), do these steps that follow:
(a) Remove the screws (11) from the cap (7).
(b) Remove and discard the chain assembly (13).
(c) Clean the screw location holes on the cap (7) and the screws (11) with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(a) Open the access door 622KB.
(b) On the refuel/defuel panel 800VU:
1 Put the MODE SELECT switch in the OFF position and lower the guard.
a Make sure that the DEFUEL/XFR valve is in shut position (light 21QU goes off).
2 Put all the REFUEL VALVES switches in the NORM position and lower the guard.
(c) Close the access door 622KB.
(8) Remove the coupling (4).
(9) If necessary discard the coupling (4).
(10) Put blanking plugs on the disconnected line ends.
(11) Remove and discard the O-rings (2) and (10).
(1) Remove the refuel coupling-cap (7) from the coupling (4).
(2) Disconnect the chain (6) from the lug (5).
NOTE: The chain (6) is spring-loaded into a protection sleeve on the cap (7).
(3) Put a container below the coupling (4). Operate the coupling check-valve with hand to drain all the remaining fuel. Remove the container. (4) If it is necessary to replace the chain assembly (13), do these steps that follow:
(a) Remove the screws (11) from the cap (7).
(b) Remove and discard the chain assembly (13).
(c) Clean the screw location holes on the cap (7) and the screws (11) with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
NOTE: It is possible that there is a washer behind the nuts (3) and (8). You will subsequently remove and keep the washer(s).
(5) Do the steps that follow: (a) Open the access door 622KB.
(b) On the refuel/defuel panel 800VU:
1 Put the MODE SELECT switch in the OFF position and lower the guard.
a Make sure that the DEFUEL/XFR valve is in shut position (light 21QU goes off).
2 Put all the REFUEL VALVES switches in the NORM position and lower the guard.
(c) Close the access door 622KB.
NOTE: If operating in battery power, do not keep the door open longer than necessary because the battery can discharge.
(6) For the bolts (1) and (9) where there is a washer behind the nuts (3) and (8): - Make a temporary mark on the coupling (4), so that you can install the same washer in the same position.
(8) Remove the coupling (4).
(9) If necessary discard the coupling (4).
(10) Put blanking plugs on the disconnected line ends.
(11) Remove and discard the O-rings (2) and (10).
Refuel Coupling/Cap - Right Wing