Functional Test of the LP Fuel Shut Off Valves
TASK 28-24-00-040-001-A
Functional Test of the LP Fuel Shut Off Valves
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-24-00-941-060-A
Subtask 28-24-00-720-060-A
Subtask 28-24-00-410-057-A
[Rev.10 from 2021]
2026.04.02 06:17:33 UTC
Functional Test of the LP Fuel Shut Off Valves
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [12QM] (VALVE-LP FUEL, ENG 1) | |
| 522AT | |
| FOR [13QM] (VALVE-LP FUEL, ENG 2) | |
| 622AT | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 57-41-37-000-003-A | Removal of the Access Panel |
| TASK 57-41-37-400-003-A | Installation of the Access Panel |
Subtask 28-24-00-941-060-A
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
(3) Put a WARNING NOTICE(S) in the cockpit to tell persons not to operate the APU or bleed air.
Subtask 28-24-00-010-056-A WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
(1) You must obey the fuel safety procedures when you do work on the fuel system (Ref. AMM TASK 28-00-00-910-001). (2) Put the SAFETY BARRIER(S) in position.
(3) Put a WARNING NOTICE(S) in the cockpit to tell persons not to operate the APU or bleed air.
B. Get Access
LP Fuel Shut Off Valve - Location and Detail ** ON A/C NOT FOR ALL
LP Fuel Shut off Valve - Location and Detail ** ON A/C NOT FOR ALL
(1) Put the ACCESS PLATFORM 3M (10 FT) in position.
(2) Remove the applicable access panel(s) (Ref. AMM TASK 57-41-37-000-003):
(a) FOR [12QM] (VALVE-LP FUEL, ENG 1)
remove 522AT
(b) FOR [13QM] (VALVE-LP FUEL, ENG 2)
remove 622AT.
Subtask 28-24-00-860-064-A
LP Fuel Shut Off Valve - Location and Detail ** ON A/C NOT FOR ALL
LP Fuel Shut off Valve - Location and Detail ** ON A/C NOT FOR ALL (2) Remove the applicable access panel(s) (Ref. AMM TASK 57-41-37-000-003):
(a) FOR [12QM] (VALVE-LP FUEL, ENG 1)
remove 522AT
(b) FOR [13QM] (VALVE-LP FUEL, ENG 2)
remove 622AT.
C. Aircraft Maintenance Configuration
(1) Make sure that the APU does not operate and there is no bleed air.
(2) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(3) Do the EIS start procedure (ECAM only) (Ref. AMM TASK 31-60-00-860-001).
Subtask 28-24-00-865-070-A (1) Make sure that the APU does not operate and there is no bleed air.
(2) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(3) Do the EIS start procedure (ECAM only) (Ref. AMM TASK 31-60-00-860-001).
D. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FUEL/LP VALVE/MOT1/ENG2 | 2QG | A09 |
| 49VU | FUEL/LP VALVE/MOT1/ENG1 | 1QG | A08 |
| 121VU | FUEL/LP VALVE/MOT2/ENG2 | 4QG | M26 |
| 121VU | FUEL/LP VALVE/MOT2/ENG1 | 3QG | M25 |
Subtask 28-24-00-720-060-A
A. Test of the Valve 12QM
(1) In the test that follows, on each operation of the LP valve:
Subtask 28-24-00-720-061-A (1) In the test that follows, on each operation of the LP valve:
- make sure that the see/feel indicator operates smoothly, from the valve open (valve closed) position to the valve closed (valve open) position
- make sure that the see/feel indicator marks are accurately aligned in the valve open position
- make sure that the see/feel indicator marks are at 90 degrees to each other in the valve closed position.
| ACTION | RESULT |
|---|---|
| 1.On the panel 121VU: | |
| The ENG 1 LP valve MOTOR 2 SUPPLY and CONTROL are isolated. |
| 2.On the ECAM CP: | On the ECAM lower DU: |
|
|
| 3.On the LP valve actuator 9QG: | |
| The indicator shows that the valve is closed. |
| 4.On the panel 115VU: | On the ECAM lower DU: |
|
|
| 5.On the LP valve actuator 9QG: | |
|
|
| The indicator shows that the valve is open. |
| 6.On the panel 115VU: | On the ECAM lower DU: |
|
|
| 7.On the LP valve actuator 9QG: | |
|
|
| The indicator shows that the valve is closed. |
| 8.On the panel 121VU: | |
| The ENG 1 LP valve MOTOR 2 SUPPLY and CONTROL are energized. |
| 9.On the panel 49VU: | |
| The ENG 1 LP valve MOTOR 1 SUPPLY and CONTROL are isolated. |
| | On the ECAM lower DU:
|
| 10.On the panel 115VU: | On the ECAM lower DU: |
|
|
| 11.On the LP valve actuator 9QG: | |
|
|
| The indicator shows that the valve is open. |
| 12.On the panel 115VU: | On the ECAM lower DU: |
|
|
| 13.On the LP valve actuator 9QG: | |
|
|
| The indicator shows that the valve is closed. |
| 14.On the panel 49VU: | |
| The ENG 1 LP valve MOTOR 1 SUPPLY and CONTROL are energized. |
B. Test of the Valve 13QM
(1) In the test that follows, on each operation of the LP valve:
5. Close-up(1) In the test that follows, on each operation of the LP valve:
- make sure that the see/feel indicator operates smoothly, from the valve open (valve closed) position to the valve closed (valve open) position
- make sure that the see/feel indicator marks are accurately aligned in the valve open position
- make sure that the see/feel indicator marks are at 90 degrees to each other in the valve closed position.
| ACTION | RESULT |
|---|---|
| 1.On the panel 121VU: | |
| The ENG 2 LP valve MOTOR 2 SUPPLY and CONTROL are isolated. |
| 2.On the ECAM CP: | On the ECAM lower DU: |
|
|
| 3.On the ENG 2 LP valve actuator 10QG: | |
| The indicator shows that the valve is closed. |
| 4.On the panel 115VU: | On the ECAM lower DU: |
|
|
| 5.On the LP valve actuator 10QG: | |
|
|
| The indicator shows that the valve is open. |
| 6.On the panel 115VU: | On the ECAM lower DU: |
|
|
| 7.On the LP valve actuator 10QG: | |
|
|
| The indicator shows that the valve is closed. |
| 8.On the panel 121VU: | |
| The ENG 2 LP valve MOTOR 2 SUPPLY and CONTROL are energized. |
| 9.On the panel 49VU: | |
| The ENG 2 LP valve MOTOR 1 SUPPLY and CONTROL are isolated. |
| | On the ECAM lower DU: |
| |
|
| 10.On the LP valve actuator 10QG: | |
| The indicator shows that the valve is closed. |
| 11.On the panel 115VU: | On the ECAM lower DU: |
|
|
| 12.On the LP valve actuator 10QG: | |
|
|
| The indicator shows that the valve is open. |
| 13.On the panel 115VU: | On the ECAM lower DU: |
|
|
| 14.On the LP valve actuator 10QG: | |
|
|
| 15.On the panel 49VU: | |
| The ENG 2 LP valve MOTOR 1 SUPPLY and CONTROL are energized. |
Subtask 28-24-00-410-057-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panel(s) (Ref. AMM TASK 57-41-37-400-003):
(a) FOR [12QM] (VALVE-LP FUEL, ENG 1)
install 522AT
(b) FOR [13QM] (VALVE-LP FUEL, ENG 2)
install 622AT.
Subtask 28-24-00-860-065-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the applicable access panel(s) (Ref. AMM TASK 57-41-37-400-003):
(a) FOR [12QM] (VALVE-LP FUEL, ENG 1)
install 522AT
(b) FOR [13QM] (VALVE-LP FUEL, ENG 2)
install 622AT.
B. Aircraft Maintenance Configuration
(1) On the ECAM CP, put the BRT switches to the OFF position.
(2) De-energize the aircraft electrical networks (Ref. AMM TASK 24-41-00-862-002).
(3) Make an applicable entry in the aircraft log.
Subtask 28-24-00-942-059-A (1) On the ECAM CP, put the BRT switches to the OFF position.
(2) De-energize the aircraft electrical networks (Ref. AMM TASK 24-41-00-862-002).
(3) Make an applicable entry in the aircraft log.
C. Removal of Equipment
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the SAFETY BARRIERS.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the SAFETY BARRIERS.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.