W DOC AIRBUS | AMM A320F

Installation of the APU Fuel Pressure Switch


TASK 28-22-15-400-001-A
Installation of the APU Fuel Pressure Switch


WARNING: OBEY THE FUEL SAFETY PROCEDURES.
FIN: 7QC
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
1
WARNING NOTICE(S)
No specific
Torque wrench: range to between 3.3 and 2.7 m.daN (24.34 and 19.91 lbf.ft ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
No specific
corrosion-resistant steel lockwire 0.6 mm (0.024 in.) dia
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
4
O-RINGS
AIPC 28-22-03-01-210
4
O-RINGS
AIPC 28-22-83-01-330
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 28-00-00-910-001-A
Fuel Safety Procedures
TASK 28-22-00-710-002-A
Operational Test of the APU Fuel-Pump System
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
3. Job Set-up
Subtask 28-22-15-860-050-A
A. Aircraft Maintenance Configuration
   (1) When you do maintenance work on the fuel system you must obey the fuel safety procedures (Ref. AMM TASK 28-00-00-910-001).
   (2) On the APU section of the overhead panel 25VU, make sure that the APU MASTER SW is in the off position (the ON legend is off).
   (3) On the FUEL overhead panel 40VU, make sure that all L TK PUMPS and R TK PUMPS pushbutton switches are released (the OFF legends are on).
   (4) Make sure that the WARNING NOTICE(S) is in position:
  • on the overhead panel 25VU, to tell persons not to operate the APU MASTER SW,
  • on the FUEL panel 40VU, to tell persons not to operate the fuel system,
  • on the APU FIRE panel 20VU, to tell persons not to operate the fire extinguishing system.
   (5) Make sure that the left MLG door is open (Ref. AMM TASK 32-12-00-010-001).
   (6) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the MLG door.
Subtask 28-22-15-865-052-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAPU/FUEL/BLOW OFF/PUMP2QCB14
** ON A/C NOT FOR ALL
121VUAPU/FUEL/BLOW OFF/CTL1QCK39
** ON A/C ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
121VUAPU/FUEL/PUMP/CTL3QCM38
** ON A/C NOT FOR ALL
121VUAPU/FUEL/BLOW OFF/CTL1QCP38
4. Procedure
Subtask 28-22-15-420-051-A Subtask 28-22-15-865-053-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAPU/FUEL/BLOW OFF/PUMP2QCB14
** ON A/C NOT FOR ALL
121VUAPU/FUEL/BLOW OFF/CTL1QCK39
** ON A/C ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
121VUAPU/FUEL/PUMP/CTL3QCM38
** ON A/C NOT FOR ALL
121VUAPU/FUEL/BLOW OFF/CTL1QCP38
Subtask 28-22-15-710-050-A
C. Test
   (1) Do the operational test of the APU fuel pump system (
Ref. AMM TASK 28-22-00-710-002).
   (2) Examine the connections of the APU fuel pressure switch for leaks.
NOTE: Leaks are not permitted.
5. Close-up
Subtask 28-22-15-410-052-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
   (3) Close the LH MLG door. (Ref. AMM TASK 32-12-00-410-001)
   (4) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.02 06:17:31 UTC