W DOC AIRBUS | AMM A320F

Operational Test of the APU Fuel Pump


TASK 28-22-00-710-006-A
Operational Test of the APU Fuel Pump


1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
STEPLADDER 2.0 M (6.6 FT)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
3. Job Set-up
Subtask 28-22-00-860-056-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) On the APU section of the overhead panel 25VU, make sure that the APU MASTER SW is in the off position (the ON legend is off).
   (3) On the FUEL overhead panel 40VU, make sure that all L TK PUMPS and the R TK PUMPS pushbutton switches are released (the OFF legends are on).
Subtask 28-22-00-865-053-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAPU/FUEL/BLOW OFF/PUMP2QCB14
** ON A/C NOT FOR ALL
121VUAPU/FUEL/BLOW OFF/CTL1QCK39
** ON A/C ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
121VUAPU/FUEL/LP VALVE/CTL1QFM40
121VUAPU/FUEL/LP VALVE/SPLY2QFM39
121VUAPU/FUEL/PUMP/CTL3QCM38
** ON A/C NOT FOR ALL
121VUAPU/FUEL/BLOW OFF/CTL1QCP38
Subtask 28-22-00-010-052-A
C. Get Access
   (1) Open the LH main landing-gear (MLG) door (Ref. AMM TASK 32-12-00-010-001).
   (2) Put the STEPLADDER 2.0 M (6.6 FT) in position at the LH MLG door.
4. Procedure
Subtask 28-22-00-710-053-A
A. Operational Test of the APU Fuel Pump
NOTE: You can feel with your hand when the APU fuel pump operates.
ACTION
RESULT
1.On the APU section of the overhead panel 25VU:
  • push the APU MASTER SW pushbutton switch to the ON position.
On the APU section of the overhead panel 25VU:
  • the ON legend in the APU MASTER SW comes on.

At the APU Fuel Pump 4QC on the FR42/ZONE 140:
  • the APU fuel pump operates.
2.On the APU section of the overhead panel 25VU:
  • release the APU MASTER SW pushbutton switch to the off position.
On the APU section of the overhead panel 25VU:
  • the ON legend in the APU MASTER SW goes off.

At the APU Fuel Pump 4QC on the FR42/ZONE 140:
  • the APU fuel pump stops.
5. Close-up
Subtask 28-22-00-410-054-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the stepladder from the LH MLG door.
   (3) Close the LH MLG door (Ref. AMM TASK 32-12-00-410-001).
Subtask 28-22-00-860-057-A
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:17:30 UTC