Operational Test of the APU Fuel Pump
TASK 28-22-00-710-006-A
Operational Test of the APU Fuel Pump
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 28-22-00-860-056-A
Subtask 28-22-00-710-053-A
Subtask 28-22-00-410-054-A
[Rev.10 from 2021]
2026.04.02 06:17:30 UTC
Operational Test of the APU Fuel Pump
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | STEPLADDER 2.0 M (6.6 FT) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
Subtask 28-22-00-860-056-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) On the APU section of the overhead panel 25VU, make sure that the APU MASTER SW is in the off position (the ON legend is off).
(3) On the FUEL overhead panel 40VU, make sure that all L TK PUMPS and the R TK PUMPS pushbutton switches are released (the OFF legends are on).
Subtask 28-22-00-865-053-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) On the APU section of the overhead panel 25VU, make sure that the APU MASTER SW is in the off position (the ON legend is off).
(3) On the FUEL overhead panel 40VU, make sure that all L TK PUMPS and the R TK PUMPS pushbutton switches are released (the OFF legends are on).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 28-22-00-010-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | APU/FUEL/BLOW OFF/PUMP | 2QC | B14 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | APU/FUEL/BLOW OFF/CTL | 1QC | K39 |
| ** ON A/C ALL | |||
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
| 121VU | APU/FUEL/LP VALVE/CTL | 1QF | M40 |
| 121VU | APU/FUEL/LP VALVE/SPLY | 2QF | M39 |
| 121VU | APU/FUEL/PUMP/CTL | 3QC | M38 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | APU/FUEL/BLOW OFF/CTL | 1QC | P38 |
C. Get Access
(1) Open the LH main landing-gear (MLG) door (Ref. AMM TASK 32-12-00-010-001).
(2) Put the STEPLADDER 2.0 M (6.6 FT) in position at the LH MLG door.
4. Procedure(1) Open the LH main landing-gear (MLG) door (Ref. AMM TASK 32-12-00-010-001).
(2) Put the STEPLADDER 2.0 M (6.6 FT) in position at the LH MLG door.
Subtask 28-22-00-710-053-A
A. Operational Test of the APU Fuel Pump
5. Close-upNOTE: You can feel with your hand when the APU fuel pump operates.
| ACTION | RESULT |
|---|---|
1.On the APU section of the overhead panel 25VU:
| On the APU section of the overhead panel 25VU:
|
| | At the APU Fuel Pump 4QC on the FR42/ZONE 140:
|
2.On the APU section of the overhead panel 25VU:
| On the APU section of the overhead panel 25VU:
|
| | At the APU Fuel Pump 4QC on the FR42/ZONE 140:
|
Subtask 28-22-00-410-054-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the stepladder from the LH MLG door.
(3) Close the LH MLG door (Ref. AMM TASK 32-12-00-410-001).
Subtask 28-22-00-860-057-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the stepladder from the LH MLG door.
(3) Close the LH MLG door (Ref. AMM TASK 32-12-00-410-001).