Installation of the Fuel Pump Strainers
TASK 28-21-54-400-002-A
Installation of the Fuel Pump Strainers
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 28-21-54-941-056-A ** ON A/C NOT FOR ALL
Subtask 28-21-54-420-052-A ** ON A/C NOT FOR ALL
Subtask 28-21-54-410-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:30 UTC
Installation of the Fuel Pump Strainers
WARNING:
MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING NOTICES ARE IN POSITION.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 192QM ** ON A/C NOT FOR ALL
FIN: 193QM ** ON A/C NOT FOR ALL
FIN: 5QM ** ON A/C NOT FOR ALL
FIN: 6QM ** ON A/C NOT FOR ALL
FIN: 7QM ** ON A/C NOT FOR ALL
FIN: 8QM ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 193QM ** ON A/C NOT FOR ALL
FIN: 5QM ** ON A/C NOT FOR ALL
FIN: 6QM ** ON A/C NOT FOR ALL
FIN: 7QM ** ON A/C NOT FOR ALL
FIN: 8QM ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | SAFETY BARRIER(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.06HAA1) | Coating Sealant-Fuel Tank Brushable - |
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 540AB, 540AZ, 540BZ, 640AB, 640AZ, 640BZ |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-11-28-650-003-A | Pressure Refuel with Automatic Control |
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 28-25-00-650-003-A | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-650-003-A-01 | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-869-001-A | Fuel Transfer |
| TASK 57-27-11-000-001-A | Removal of the Access Panel |
| TASK 57-27-11-400-001-A | Installation of the Access Panel |
Subtask 28-21-54-941-056-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) Make sure that the SAFETY BARRIER(S) is in position.
Subtask 28-21-54-865-054-A ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
(1) You must obey the fuel safety procedures (Ref. AMM TASK 28-10-00-910-001) when you do work in a fuel tank. (2) Make sure that the SAFETY BARRIER(S) is in position.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 28-21-54-860-054-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/L WING TK/PUMP2 SPLY | 7QA | N26 |
| 121VU | FUEL/L WING TK/PUMP1 SPLY | 1QA | N23 |
| 121VU | FUEL/R WING TK/PUMP2 SPLY | 8QA | Q26 |
| 121VU | FUEL/R WING TK/PUMP1 SPLY | 2QA | Q23 |
| 123VU | L WING TK/PUMP 1/STBY SPLY | 11QA | AD12 |
| 123VU | R WING TK/PUMP 1/STBY SPLY | 12QA | AE12 |
C. Aircraft Maintenance Configuration
(1) Make sure that the center tank and the applicable wing fuel tank are defuelled (Ref. AMM TASK 28-25-00-650-001).
(2) Make sure that the remaining fuel has been drained from the applicable wing fuel tank (Ref. AMM TASK 28-25-00-650-003).
(3) Make sure that the ACCESS PLATFORM 3M (10 FT) is below the applicable access panel 540AB(640AB).
(4) Make sure that the applicable access panel 540AB(640AB) is removed (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-001).
(5) Make sure that the applicable surge door is open.
(a) For 6QM(8QM), 192QM(193QM):
(b) For 5QM(7QM):
(6) Make sure that the applicable tool is on the surge door:
4. Procedure(1) Make sure that the center tank and the applicable wing fuel tank are defuelled (Ref. AMM TASK 28-25-00-650-001).
(2) Make sure that the remaining fuel has been drained from the applicable wing fuel tank (Ref. AMM TASK 28-25-00-650-003).
(3) Make sure that the ACCESS PLATFORM 3M (10 FT) is below the applicable access panel 540AB(640AB).
(4) Make sure that the applicable access panel 540AB(640AB) is removed (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-001).
(5) Make sure that the applicable surge door is open.
(a) For 6QM(8QM), 192QM(193QM):
(b) For 5QM(7QM):
(6) Make sure that the applicable tool is on the surge door:
- For 540BZ(640BZ) the 98D57004014000 HOOK-COVER (RIB2-SURGE DOORS)
- For 540AZ(640AZ) the 98D57004013000 HOOK-COVER (RIB 2 SURGE DOORS).
Subtask 28-21-54-420-052-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
(1) Clean the component interfaces and the adjacent areas with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(2) Make sure that the parts retained from the removed component are clean and in the correct condition.
(3) Do an inspection of the component interfaces and the adjacent area.
Subtask 28-21-54-420-053-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent areas with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(2) Make sure that the parts retained from the removed component are clean and in the correct condition.
(3) Do an inspection of the component interfaces and the adjacent area.
B. Installation of the Fuel Pump Strainer
(1) For the strainers 5QM(7QM), 6QM(8QM):
(a) Put the strainer (1) in position on the strainer assembly.
(b) Install the six bolts (2).
(c) Apply Coating Sealant-Fuel Tank Brushable - (Material No.06HAA1) to the bolts (2).
(2) For the suction valve strainer:
(a) Put the suction valve strainer assembly in position.
(b) Install the bolt (5).
(c) Install the eight bolts (6).
(d) Apply Coating Sealant-Fuel Tank Brushable - (Material No.06HAA1) to the bolts (5) and (6).
5. Close-up(1) For the strainers 5QM(7QM), 6QM(8QM):
(a) Put the strainer (1) in position on the strainer assembly.
(b) Install the six bolts (2).
(c) Apply Coating Sealant-Fuel Tank Brushable - (Material No.06HAA1) to the bolts (2).
(2) For the suction valve strainer:
(a) Put the suction valve strainer assembly in position.
(b) Install the bolt (5).
(c) Install the eight bolts (6).
(d) Apply Coating Sealant-Fuel Tank Brushable - (Material No.06HAA1) to the bolts (5) and (6).
Subtask 28-21-54-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the applicable tool 98D57004013000 HOOK-COVER (RIB 2 SURGE DOORS) or 98D57004014000 HOOK-COVER (RIB2-SURGE DOORS).
(3) Close the applicable fuel-surge access door 540AZ 640AZ 540BZ 640BZ.
(4) Install the applicable access panel 540AB 640AB (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-400-001).
Subtask 28-21-54-865-055-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the applicable tool 98D57004013000 HOOK-COVER (RIB 2 SURGE DOORS) or 98D57004014000 HOOK-COVER (RIB2-SURGE DOORS).
(3) Close the applicable fuel-surge access door 540AZ 640AZ 540BZ 640BZ.
(4) Install the applicable access panel 540AB 640AB (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-400-001).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 28-21-54-650-052-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/L WING TK/PUMP2 SPLY | 7QA | N26 |
| 121VU | FUEL/L WING TK/PUMP1 SPLY | 1QA | N23 |
| 121VU | FUEL/R WING TK/PUMP2 SPLY | 8QA | Q26 |
| 121VU | FUEL/R WING TK/PUMP1 SPLY | 2QA | Q23 |
| 123VU | L WING TK/PUMP 1/STBY SPLY | 11QA | AD12 |
| 123VU | R WING TK/PUMP 1/STBY SPLY | 12QA | AE12 |
C. Fuel Configuration
(1) Refuel, defuel or transfer fuel as applicable (Ref. AMM TASK 12-11-28-650-003), (Ref. AMM TASK 28-25-00-650-001) or (Ref. AMM TASK 28-25-00-869-001).
Subtask 28-21-54-942-052-A ** ON A/C NOT FOR ALL (1) Refuel, defuel or transfer fuel as applicable (Ref. AMM TASK 12-11-28-650-003), (Ref. AMM TASK 28-25-00-650-001) or (Ref. AMM TASK 28-25-00-869-001).
D. Removal of Equipment
(1) Remove the safety barriers.
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the safety barriers.
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Fuel Pump Strainers