Removal of the Fuel Pump Strainers
TASK 28-21-54-000-002-A
Removal of the Fuel Pump Strainers
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-21-54-941-055-A ** ON A/C NOT FOR ALL
Subtask 28-21-54-020-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 07:02:45 UTC
Removal of the Fuel Pump Strainers
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 192QM ** ON A/C NOT FOR ALL
FIN: 193QM ** ON A/C NOT FOR ALL
FIN: 5QM ** ON A/C NOT FOR ALL
FIN: 6QM ** ON A/C NOT FOR ALL
FIN: 7QM ** ON A/C NOT FOR ALL
FIN: 8QM ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 193QM ** ON A/C NOT FOR ALL
FIN: 5QM ** ON A/C NOT FOR ALL
FIN: 6QM ** ON A/C NOT FOR ALL
FIN: 7QM ** ON A/C NOT FOR ALL
FIN: 8QM ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| No specific | 1 | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| 98D57004013000 | 1 | HOOK-COVER (RIB 2 SURGE DOORS) |
| 98D57004014000 | 1 | HOOK-COVER (RIB2-SURGE DOORS) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 540AB, 540AZ, 540BZ, 640AB, 640AZ, 640BZ |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 28-25-00-650-003-A | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-650-003-A-01 | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 57-27-11-000-001-A | Removal of the Access Panel |
Subtask 28-21-54-941-055-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
Subtask 28-21-54-860-053-A ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
(1) You must obey the fuel safety procedures (Ref. AMM TASK 28-10-00-910-001) when you do work in a fuel tank. (2) Put the SAFETY BARRIER(S) in position.
B. Aircraft Maintenance Configuration
(1) Defuel the center fuel tank and the applicable wing fuel tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the remaining fuel from the applicable wing fuel tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-21-54-865-053-A ** ON A/C NOT FOR ALL (1) Defuel the center fuel tank and the applicable wing fuel tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the remaining fuel from the applicable wing fuel tank (Ref. AMM TASK 28-25-00-650-003).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 28-21-54-010-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/L WING TK/PUMP2 SPLY | 7QA | N26 |
| 121VU | FUEL/L WING TK/PUMP1 SPLY | 1QA | N23 |
| 121VU | FUEL/R WING TK/PUMP2 SPLY | 8QA | Q26 |
| 121VU | FUEL/R WING TK/PUMP1 SPLY | 2QA | Q23 |
| 123VU | L WING TK/PUMP 1/STBY SPLY | 11QA | AD12 |
| 123VU | R WING TK/PUMP 1/STBY SPLY | 12QA | AE12 |
D. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) below the applicable access panel.
(a) For 5QM, 6QM, 192QM:
(a) For 5QM, 6QM, 192QM:
(b) For 7QM, 8QM, 193QM:
(3) Open the applicable surge door.
(a) For 6QM(8QM), 192QM(193QM):
(b) For 5QM(7QM):
(4) Install the applicable tool on the surge door.
(a) For 6QM(8QM), 192QM(193QM):
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT) below the applicable access panel.
(a) For 5QM, 6QM, 192QM:
- below access panel 540AB.
- below access panel 640AB.
(a) For 5QM, 6QM, 192QM:
(b) For 7QM, 8QM, 193QM:
(3) Open the applicable surge door.
(a) For 6QM(8QM), 192QM(193QM):
(b) For 5QM(7QM):
(4) Install the applicable tool on the surge door.
(a) For 6QM(8QM), 192QM(193QM):
- install 98D57004014000 HOOK-COVER (RIB2-SURGE DOORS).
- install 98D57004013000 HOOK-COVER (RIB 2 SURGE DOORS).
Subtask 28-21-54-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Fuel Pump Strainers
(1) For the flat strainers 5QM(7QM), 6QM(8QM):
(a) Remove and keep the six bolts (2).
(b) Remove and keep the flat strainer (1).
(2) For the suction valve strainer 192QM(193QM):
(a) Remove and keep the eight bolts (6).
(b) Remove and keep the bolt (5).
(c) Remove and keep the suction valve strainer assembly.
(1) For the flat strainers 5QM(7QM), 6QM(8QM):
(a) Remove and keep the six bolts (2).
(b) Remove and keep the flat strainer (1).
(2) For the suction valve strainer 192QM(193QM):
(a) Remove and keep the eight bolts (6).
(b) Remove and keep the bolt (5).
(c) Remove and keep the suction valve strainer assembly.
Fuel Pump Strainers