Removal of the Fuel Pump Strainer
TASK 28-21-54-000-001-A
Removal of the Fuel Pump Strainer
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-21-54-941-052-A ** ON A/C NOT FOR ALL
Subtask 28-21-54-020-050-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:17:30 UTC
Removal of the Fuel Pump Strainer
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 5QM ** ON A/C NOT FOR ALL
FIN: 6QM ** ON A/C NOT FOR ALL
FIN: 7QM ** ON A/C NOT FOR ALL
FIN: 8QM ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 6QM ** ON A/C NOT FOR ALL
FIN: 7QM ** ON A/C NOT FOR ALL
FIN: 8QM ** ON A/C NOT FOR ALL
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT) |
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR) | ||
| FOR [7QM] (STRAINER-PUMP INLET, R WING TK INR) | ||
| 98D57004013000 | 1 | HOOK-COVER (RIB 2 SURGE DOORS) |
| FOR [6QM] (STRAINER-PUMP INLET, L WING TK INR) | ||
| FOR [8QM] (STRAINER-PUMP INLET, R WING TK OUTR) | ||
| 98D57004014000 | 1 | HOOK-COVER (RIB2-SURGE DOORS) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR) | |
| FOR [7QM] (STRAINER-PUMP INLET, R WING TK INR) | |
| 540AZ, 640AZ | |
| FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR) | |
| FOR [6QM] (STRAINER-PUMP INLET, L WING TK INR) | |
| 540AB | |
| FOR [6QM] (STRAINER-PUMP INLET, L WING TK INR) | |
| FOR [8QM] (STRAINER-PUMP INLET, R WING TK OUTR) | |
| 540BZ, 640BZ | |
| FOR [7QM] (STRAINER-PUMP INLET, R WING TK INR) | |
| FOR [8QM] (STRAINER-PUMP INLET, R WING TK OUTR) | |
| 640AB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 28-25-00-650-003-A | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-650-003-A-01 | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 57-27-11-000-001-A | Removal of the Access Panel |
| FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR) | |
| FOR [7QM] (STRAINER-PUMP INLET, R WING TK INR) | |
| TASK 57-27-12-000-002-A | Removal of the Rib 2 Access Panel 540AZ(640AZ) or 540BZ(640BZ) |
| FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR) | |
| FOR [6QM] (STRAINER-PUMP INLET, L WING TK INR) | |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 57-27-11-000-001-A | Removal of the Access Panel |
| FOR [6QM] (STRAINER-PUMP INLET, L WING TK INR) | |
| FOR [8QM] (STRAINER-PUMP INLET, R WING TK OUTR) | |
| TASK 57-27-12-000-002-A | Removal of the Rib 2 Access Panel 540AZ(640AZ) or 540BZ(640BZ) |
| FOR [7QM] (STRAINER-PUMP INLET, R WING TK INR) | |
| FOR [8QM] (STRAINER-PUMP INLET, R WING TK OUTR) | |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 57-27-11-000-001-A | Removal of the Access Panel |
Subtask 28-21-54-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
Subtask 28-21-54-860-051-A ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
(1) You must obey the fuel safety procedures (Ref. AMM TASK 28-10-00-910-001) when you do work in a fuel tank. (2) Put the SAFETY BARRIER(S) in position.
B. Aircraft Maintenance Configuration
(1) Defuel the center fuel tank and the applicable wing fuel tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the remaining fuel from the applicable wing fuel tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-21-54-865-050-A ** ON A/C NOT FOR ALL (1) Defuel the center fuel tank and the applicable wing fuel tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the remaining fuel from the applicable wing fuel tank (Ref. AMM TASK 28-25-00-650-003).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 28-21-54-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/L WING TK/PUMP2 SPLY | 7QA | N26 |
| 121VU | FUEL/L WING TK/PUMP1 SPLY | 1QA | N23 |
| 121VU | FUEL/R WING TK/PUMP2 SPLY | 8QA | Q26 |
| 121VU | FUEL/R WING TK/PUMP1 SPLY | 2QA | Q23 |
| 123VU | L WING TK/PUMP 1/STBY SPLY | 11QA | AD12 |
| 123VU | R WING TK/PUMP 1/STBY SPLY | 12QA | AE12 |
D. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) below the applicable access panel:
(a) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [6QM] (STRAINER-PUMP INLET, L WING TK INR)
below access panel 540AB
(b) FOR [7QM] (STRAINER-PUMP INLET, R WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
below access panel 640AB.
(2) Remove the applicable access panel (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-001):
(a) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [6QM] (STRAINER-PUMP INLET, L WING TK INR)
540AB
(b) FOR [7QM] (STRAINER-PUMP INLET, R WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
640AB.
(3) Open the applicable surge door:
(a) FOR [6QM] (STRAINER-PUMP INLET, L WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
open 540BZ 640BZ
(b) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [7QM] (STRAINER-PUMP INLET, R WING TK INR)
open 540AZ 640AZ.
(4) Install the applicable tool on the surge door:
(a) FOR [6QM] (STRAINER-PUMP INLET, L WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
install 98D57004014000 HOOK-COVER (RIB2-SURGE DOORS)
(b) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [7QM] (STRAINER-PUMP INLET, R WING TK INR)
install 98D57004013000 HOOK-COVER (RIB 2 SURGE DOORS).
Subtask 28-21-54-010-050-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT) below the applicable access panel:
(a) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [6QM] (STRAINER-PUMP INLET, L WING TK INR)
below access panel 540AB
(b) FOR [7QM] (STRAINER-PUMP INLET, R WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
below access panel 640AB.
(2) Remove the applicable access panel (Ref. AMM TASK 28-10-00-910-002), (Ref. AMM TASK 57-27-11-000-001):
(a) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [6QM] (STRAINER-PUMP INLET, L WING TK INR)
540AB
(b) FOR [7QM] (STRAINER-PUMP INLET, R WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
640AB.
(3) Open the applicable surge door:
(a) FOR [6QM] (STRAINER-PUMP INLET, L WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
open 540BZ 640BZ
(b) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [7QM] (STRAINER-PUMP INLET, R WING TK INR)
open 540AZ 640AZ.
(4) Install the applicable tool on the surge door:
(a) FOR [6QM] (STRAINER-PUMP INLET, L WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
install 98D57004014000 HOOK-COVER (RIB2-SURGE DOORS)
(b) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [7QM] (STRAINER-PUMP INLET, R WING TK INR)
install 98D57004013000 HOOK-COVER (RIB 2 SURGE DOORS).
D. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the applicable access panel that follow:
(a) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [6QM] (STRAINER-PUMP INLET, L WING TK INR)
Below 540AB.
(b) FOR [7QM] (STRAINER-PUMP INLET, R WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
Below 640AB.
(2) Remove the applicable access panels that follow:
(a) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [6QM] (STRAINER-PUMP INLET, L WING TK INR)
Remove 540AB (Ref. AMM TASK 28-10-00-910-002) and (Ref. AMM TASK 57-27-11-000-001).
(b) FOR [7QM] (STRAINER-PUMP INLET, R WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
Remove 640AB (Ref. AMM TASK 28-10-00-910-002) and (Ref. AMM TASK 57-27-11-000-001).
(3) Remove the applicable RIB2 access panels that follow:
(a) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [7QM] (STRAINER-PUMP INLET, R WING TK INR)
Remove 540AZ ( 640AZ) (Ref. AMM TASK 57-27-12-000-002).
(b) FOR [6QM] (STRAINER-PUMP INLET, L WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
Remove 540BZ ( 640BZ) (Ref. AMM TASK 57-27-12-000-002).
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the applicable access panel that follow:
(a) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [6QM] (STRAINER-PUMP INLET, L WING TK INR)
Below 540AB.
(b) FOR [7QM] (STRAINER-PUMP INLET, R WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
Below 640AB.
(2) Remove the applicable access panels that follow:
(a) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [6QM] (STRAINER-PUMP INLET, L WING TK INR)
Remove 540AB (Ref. AMM TASK 28-10-00-910-002) and (Ref. AMM TASK 57-27-11-000-001).
(b) FOR [7QM] (STRAINER-PUMP INLET, R WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
Remove 640AB (Ref. AMM TASK 28-10-00-910-002) and (Ref. AMM TASK 57-27-11-000-001).
(3) Remove the applicable RIB2 access panels that follow:
(a) FOR [5QM] (STRAINER-PUMP INLET, L WING TK OUTR), [7QM] (STRAINER-PUMP INLET, R WING TK INR)
Remove 540AZ ( 640AZ) (Ref. AMM TASK 57-27-12-000-002).
(b) FOR [6QM] (STRAINER-PUMP INLET, L WING TK INR), [8QM] (STRAINER-PUMP INLET, R WING TK OUTR)
Remove 540BZ ( 640BZ) (Ref. AMM TASK 57-27-12-000-002).
Subtask 28-21-54-020-050-B ** ON A/C NOT FOR ALL
A. Removal of the Fuel Pump Strainer
(1) Remove the bolt (14) and disconnect the bonding tab (11).
(2) Remove the two bolts (8) and the three bolts (13).
(3) Remove the cowls (7) and (12).
(4) Remove the bolts (6).
(5) Release the nut (4) and disconnect the filter connector (5) from the fuel pipe (1).
(6) Carefully remove the filter connector (5).
(7) Remove the retaining ring (3) and the nut (4) from the fuel pipe (1).
(8) Remove and discard the O-ring (2) from the fuel pipe (1).
(9) Remove the bolts (9).
(10) Remove the fuel pump strainer (15).
(11) Put the PLUG-BLANKING in each disconnected line end.
(1) Remove the bolt (14) and disconnect the bonding tab (11).
(2) Remove the two bolts (8) and the three bolts (13).
(3) Remove the cowls (7) and (12).
(4) Remove the bolts (6).
(5) Release the nut (4) and disconnect the filter connector (5) from the fuel pipe (1).
(6) Carefully remove the filter connector (5).
(7) Remove the retaining ring (3) and the nut (4) from the fuel pipe (1).
(8) Remove and discard the O-ring (2) from the fuel pipe (1).
(9) Remove the bolts (9).
(10) Remove the fuel pump strainer (15).
(11) Put the PLUG-BLANKING in each disconnected line end.
Fuel Pump Strainer