Leak Test of the Main Fuel-Pump-System Pipelines
TASK 28-21-00-790-001-A
Leak Test of the Main Fuel-Pump-System Pipelines
To leak test the pipes installed or replaced in the fuel-pump system pipelines.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-21-00-941-070-A
Subtask 28-21-00-860-077-A
[Rev.10 from 2021]
2026.04.02 07:01:20 UTC
Leak Test of the Main Fuel-Pump-System Pipelines
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
ZONE: 211
1. Reason for the JobTo leak test the pipes installed or replaced in the fuel-pump system pipelines.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY BARRIER(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-11-28-650-003-A | Pressure Refuel with Automatic Control |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 28-21-00-941-070-A
A. Safety Precautions
(1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 28-21-00-860-076-A (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
B. Aircraft Maintenance Configuration
(2) Do the EIS start procedure (ECAM only) (Ref. AMM TASK 31-60-00-860-001), then:
(4) On the panel 40VU:
4. ProcedureWARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002). (2) Do the EIS start procedure (ECAM only) (Ref. AMM TASK 31-60-00-860-001), then:
- on the ECAM control panel (CP), push (in) the FUEL push icon switch
- make sure that the FUEL page shows on the ECAM lower Display Unit (DU).
(4) On the panel 40VU:
- push (in) the X-FEED P/BSW.
WARNING:
WHEN YOU OPERATE THE FUEL PUMPS DURING A MAINTENANCE PROCEDURE, A MAINTENANCE PERSON MUST BE IN THE COCKPIT. THIS PERSON MUST STOP THE PUMPS WHEN THE LOW PRESSURE FAULT LIGHT(S) (ON PANEL 40VU) COME ON, TO PREVENT OPERATION OF THE PUMPS(S) WITHOUT FUEL ('DRY RUNNING'). OPERATION OF THE PUMPS WITHOUT FUEL CAN CAUSE A FIRE.
NOTE: The wing-tank fuel-pump suction valves have a controlled fuel leak rate when in the closed position. The fuel flow (controlled leak) is to prevent the formation of ice in the mouth of the suction valve. The fuel flow is only from the center tank to the wing tank. The maximum permitted flow is 210 kg (463 lb/Hour).
Subtask 28-21-00-790-050-B A. Leak Test of the Main Fuel-Pump-System Pipelines (Left Wing, Fuselage and Center Tank)
Subtask 28-21-00-790-051-B | ACTION | RESULT |
|---|---|
1.On fuel control-panel 40VU:
| On fuel control-panel 40VU:
|
2.On the lower ECAM System Display (SD) FUEL page:
| On the lower ECAM SD FUEL page:
NOTE: There may be small gauge fluctuations that should be taken into account. |
3.On the lower ECAM SD FUEL page:
| On the lower ECAM SD FUEL page:
|
| 4.If the fuel quantity in the tanks increases, stop the test. Find the indication of the fuel leakage and repair the leak. Do the test again. | |
5.On fuel control-panel 40VU:
| On fuel control-panel 40VU:
|
B. Leak Test of the Main Fuel-Pump-System Pipelines (Right Wing, Fuselage and Center Tank)
5. Close-up| ACTION | RESULT |
|---|---|
1.On fuel control-panel 40VU:
| On fuel control-panel 40VU:
|
2.On the lower ECAM System Display (SD) FUEL page:
| On the lower ECAM SD FUEL page:
NOTE: There may be small gauge fluctuations that should be taken into account. |
3.On the lower ECAM SD FUEL page:
| On the lower ECAM SD FUEL page:
|
| 4.If the fuel quantity in the tanks increases, stop the test. Find the indication of the fuel leakage and repair the leak. Do the test again. | |
5.On fuel control-panel 40VU:
| On fuel control-panel 40VU:
|
Subtask 28-21-00-860-077-A
A. Aircraft Maintenance Configuration
(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 28-21-00-942-075-A CAUTION:
BEFORE YOU CLOSE THE CROSSFEED VALVE, MAKE SURE THAT THE FUEL PUMP(S) IS(ARE) OFF. THIS WILL PREVENT DAMAGE TO THE CROSSFEED VALVE.
(1) In the cockpit, on fuel panel 40VU, release the X-FEED pushbutton switch.(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
B. Removal of Equipment
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the safety barriers.
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the safety barriers.
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.