W DOC AIRBUS | AMM A320F

Remove Air Release Valve for Functional Check of Float


TASK 28-21-00-720-802-A
Remove Air Release Valve for Functional Check of Float


FIN: 86QM
FIN: 87QM
1. Reason for the Job
Refer to the MPD TASK: 282100-10
REMOVE AIR RELEASE VALVE FOR FUNCTIONAL CHECK OF FLOAT
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 28-21-41-000-001-A
Removal of the Low Pressure (LP) Air-Release-Valve
TASK 28-21-41-400-001-A
Installation of the Low Pressure (LP) Air-Release Valve
3. Job Set-up
Subtask 28-21-00-020-052-A
A. Removal of the Equipment
   (1) Remove the Air Release Valve (Ref. AMM TASK 28-21-41-000-001).
4. Procedure
Subtask 28-21-00-720-065-A
A. Send the Air Release Valve to the Workshop for Checks
   (1) Send the air-release valve to the workshop.
NOTE: This functional check will find if the air-release valve float is unserviceable.
5. Close-up
Subtask 28-21-00-420-051-A
A. Install the Equipment
   (1) Install the Air Release Valve (Ref. AMM TASK 28-21-41-400-001).
[Rev.10 from 2021] 2026.04.02 06:17:24 UTC