Operational Test of the Wing-Tank Pump-Canister Check-Valves
TASK 28-21-00-710-012-A
Operational Test of the Wing-Tank Pump-Canister Check-Valves
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-21-00-941-081-A
Subtask 28-21-00-860-092-A
[Rev.10 from 2021]
2026.04.02 06:17:23 UTC
Operational Test of the Wing-Tank Pump-Canister Check-Valves
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
ZONE: 211
1. Reason for the JobSelf Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| 622KB | |
| 192MB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-11-28-650-003-A | Pressure Refuel with Automatic Control |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 28-25-00-869-001-A | Fuel Transfer |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 28-21-00-941-081-A
A. Safety Precautions
(2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(3) Put a WARNING NOTICE(S) in position on the flight deck to tell persons not to operate the main booster pumps or crossfeed valve.
Subtask 28-21-00-010-057-A ** ON A/C NOT FOR ALL WARNING:
OBEY THE FUEL SAFETY PROCEDURES.
(1) You must obey the fuel safety procedures when you work on the fuel system (Ref. AMM TASK 28-00-00-910-001). (2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(3) Put a WARNING NOTICE(S) in position on the flight deck to tell persons not to operate the main booster pumps or crossfeed valve.
B. Get Access
(1) Open the access door 192MB.
Subtask 28-21-00-010-057-B ** ON A/C NOT FOR ALL (1) Open the access door 192MB.
NOTE: If operating in battery power:
- put the MODE SELECT switch to the OFF and guarded position
- do not keep the door open longer than necessary because the battery can discharge.
B. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) in position below zone 622.
(2) Open the access door 622KB.
Subtask 28-21-00-860-091-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT) in position below zone 622.
(2) Open the access door 622KB.
NOTE: If operating in battery power:
- put the MODE SELECT switch to the OFF and guarded position
- do not keep the door open longer than necessary because the battery can discharge.
C. Aircraft Maintenance Configuration
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001), then:
Subtask 28-21-00-860-091-B ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
(1) Energize the aircraft electrical circuits(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001), then:
- On the ECAM control panel, push (in) the FUEL pushbutton switch and make sure that the FUEL page is shown on the ECAM lower Display Unit (DU).
- The left wing and the right wing tank inner-cells contain a minimum of 1000 kg (2204.6220 lb) and a maximum of 4300 kg (9479.8746 lb).
C. Aircraft Maintenance Configuration
(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001), then:
4. ProcedureWARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
(1) Energize the aircraft electrical circuits(Ref. AMM TASK 24-41-00-861-002).
(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001), then:
- On the ECAM control panel, push (in) the FUEL pushbutton switch and make sure that the FUEL page is shown on the ECAM lower Display Unit (DU).
- The center tank contains a minimum fuel quantity of 1000 kg (2204.6220 lb)
- The left wing and the right wing tank inner-cells contain a minimum of 1000 kg (2204.6220 lb) and maximum of 4300 kg (9479.8746 lb).
WARNING:
WHEN YOU OPERATE THE FUEL PUMPS DURING A MAINTENANCE PROCEDURE, A MAINTENANCE PERSON MUST BE IN THE COCKPIT. THIS PERSON MUST STOP THE PUMPS WHEN THE LOW PRESSURE FAULT LIGHT(S) (ON PANEL 40VU) COME ON, TO PREVENT OPERATION OF THE PUMPS(S) WITHOUT FUEL ('DRY RUNNING'). OPERATION OF THE PUMPS WITHOUT FUEL CAN CAUSE A FIRE.
Subtask 28-21-00-710-073-B ** ON A/C NOT FOR ALL A. Operational Test of the Wing-Tank Pump-Canister Check-Valves
(1) Do the test that follows:
Subtask 28-21-00-710-073-C ** ON A/C NOT FOR ALL NOTE: This test is for check valves 149QM, 150QM, 151QM and 152QM installed in the left and right wing-tank fuel-pump-canisters.
(1) Do the test that follows:
| ACTION | RESULT |
|---|---|
1.On refuel/defuel control-panel 800VU:
| |
CAUTION:
BEFORE YOU CLOSE THE CROSSFEED VALVE, MAKE SURE THAT THE FUEL PUMP(S) IS(ARE) OFF. THIS WILL PREVENT DAMAGE TO THE CROSSFEED VALVE. 2.On fuel panel 40VU:
| On fuel panel 40VU:
|
| | On the ECAM lower DU:
|
3.On fuel panel 40VU:
| On fuel panel 40VU:
|
| | On the ECAM lower DU:
|
4.On fuel panel 40VU:
| On fuel panel 40VU:
|
A. Operational Test of the Wing-Tank Pump-Canister Check-Valves
(1) Do the test that follows:
5. Close-upNOTE: After you complete the maintenance procedure that follows:
- There is a risk of surge tank overflow if the MODE SEL (4QL) pushbutton switch stays in the MAN mode.
NOTE: This test is for check valves 149QM, 150QM, 151QM and 152QM installed in the left and right wing-tank fuel-pump-canisters.
(1) Do the test that follows:
| ACTION | RESULT |
|---|---|
1.On refuel/defuel control-panel 800VU:
| |
2.On fuel control-panel 40VU:
| On fuel control-panel 40VU:
|
3.On fuel control-panel 40VU:
| On fuel control-panel 40VU:
|
4.On fuel control-panel 40VU:
| On fuel control-panel 40VU:
|
5.On fuel control-panel 40VU:
| On fuel control-panel 40VU:
|
6.On fuel control-panel 40VU:
| On fuel control-panel 40VU:
|
7.On fuel control-panel 40VU:
| On fuel control-panel 40VU:
|
CAUTION:
BEFORE YOU CLOSE THE CROSSFEED VALVE, MAKE SURE THAT THE FUEL PUMP(S) IS(ARE) OFF. THIS WILL PREVENT DAMAGE TO THE CROSSFEED VALVE. 8.On fuel control-panel 40VU:
| On fuel control-panel 40VU:
|
Subtask 28-21-00-860-092-A
A. Aircraft Configuration
(1) Refuel, defuel or transfer fuel as necessary (Ref. AMM TASK 12-11-28-650-003), (Ref. AMM TASK 28-25-00-650-001) or (Ref. AMM TASK 28-25-00-869-001).
(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 28-21-00-410-057-B ** ON A/C NOT FOR ALL (1) Refuel, defuel or transfer fuel as necessary (Ref. AMM TASK 12-11-28-650-003), (Ref. AMM TASK 28-25-00-650-001) or (Ref. AMM TASK 28-25-00-869-001).
(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 622KB.
Subtask 28-21-00-410-057-D ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 622KB.
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 192MB.
Subtask 28-21-00-942-085-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 192MB.
C. Removal of Equipment
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the SAFETY BARRIERS.
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the SAFETY BARRIERS.
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.